SIP INSTALLATION
A Windows based program (called Natcomm SIP Controller) is supplied for
your
RCU-SIP
unit. This program is designed for use on PC running Windows
7 or later (on your same network). Install the program by double clicking the
supplied Program file. The program will install and a Natcomm Icon will be
installed on the desktop.
Connect RCU-SIP to the Network
Using the supplied CAT5 cable connect the NETWORK port of
RCU-SIP
to your
Internet Network, at any convenient Network Point or direct to a Switch or
Modem-Router. Connect the Supplied Power Supply and Switch the Power ON.
Wait 1-2 minutes while RCU-SIP ‘boots up’ and registers to your Network
Double Click the Icon to open the program.
Once the program has loaded
Click for IP Address
After a short delay, the
program will then display the IP
Address, Gateway Address
and Subnet Mask of
RCU-SIP
The Password is : root
Enter the Password and then
Click
Login
to
Enter
the Advanced
Settings area. This is where you can set up the SIP settings of the device.
SIP Parameter Setup
Refer to pages 17-20 for all SIP set up instructions).
A) Setting up the Extension Number
B) Setting Up a Username and Password
C) Setting Up the Network Server IP address
D) Changing from DHCP to Static IP
E) Load all Changes into the Internal ATA
F) Downloading the ATA User Guide for full ATA setting details.
5
4
(
1
2
3
4
5
6