Page 12
Natcomm
PROGRAMMING OPTIONS
DS-SIP
Switch provides for Three User Programmable settings.
Allowable Range
:
01 to 99
Default Setting is
:
15 seconds
Allowable Range
:
01 to 99
Default Setting is
:
00 seconds
Relay 2 can be used in Two different ways
:
Lock Operation
- If you want to operate Relay 2 to control a Door or Gate
Lock using the command
*
2, you should leave the setting as 00 (The
Default)
Device Operation
- If you want to operate Relay 2 to control another device
by Closing as soon as the Intercom is Triggered, then you should enter a
value of 01-99 in this area, this value is the time in seconds that the Relay will
remain closed AFTER HANG UP. This facility will allow you to for example to
control a Video Recorder and where the Video Recorder remains recording
for 01-99 seconds after Hang Up.
Relay 1 Closure Time
To Change from the Default Setting
,
in programming Mode,
Press : #1xx
Where xx = number of seconds and can be 01-99
For example, press #125 for 25 seconds
Relay 2 Operation
To Change from the Default Setting
,
in programming Mode
,
Press : #2xx
Where xx = number of seconds and can be 01-99
For example, press #215 for 15 seconds
Summary of Contents for DS-SIP