SIP INSTALLATION 

 

A Windows based program (called Natcomm SIP Controller) is supplied for 
your 

DS-SIP

 unit. This program is designed for use on PC running Windows 7 

or later (on your same network). Install the program by double clicking the 
supplied Program file. The program will install and a Natcomm Icon will be 
installed on the desktop.  
 
 

Connect DS-SIP to the Network

 

 
Using the supplied CAT5 cable connect the NETWORK port of 

DS-SIP

 to your 

Internet Network, at a convenient Network Point or direct to a Switch or 
Modem-Router. Connect the Supplied Power Adaptor and Switch the Power 
ON. 
 
 

Wait 1-2 minutes while DS-SIP ‘bots up’ and registers to your Network 

 

 
 

Double Click the Icon to open the program. Once the program has loaded,  

 

 
 

          Click for IP Address 
 

After a short delay, the 
program will then display the IP 
Address, Gateway Address 
and Subnet Mask of 

DS-SIP.

 

 

          

The Password is : root    

           Enter the Password and then

 Click 

Login

 to 

Enter

 the Advanced   

         Settings area. This is where you can set up the SIP settings of the device. 

 

          

SIP Parameter Setup  

Refer to pages 17-20 for all SIP set up instructions).

 

A)  Setting up the Extension Number 
B)  Setting Up a Username and Password 
C)  Setting Up the Network Server IP address 
D)  Changing from DHCP to Static IP 
E)  Changing the Speaker Volume of the Intercom connected to DS-SIP 
F)  Changing the Microphone Volume of the Intercom connected to DS-SIP 
G)  Load all Changes into the Internal ATA 
H)  Downloading the ATA User Guide for full ATA setting details. 

 

4

(

1

2

3

4

5

6

Summary of Contents for DS-SIP

Page 1: ...DS SIP USER GUIDE For Technical Assistance Please Ph 07 5596 5128 or Email info natcomm com au ...

Page 2: ... connected DS SIP will connect to the Network via DHCP A Windows based program called Natcomm SIP Controller is supplied for your DS SIP unit This program is designed for use on PC running Windows 7 or later on your same network Install the program by double clicking the supplied Program file The program will install and a Natcomm Icon will be installed on the desktop You will be emailed an FTP Li...

Page 3: ...0mm D Model DP3 FLUSH MOUNT Standard Size Marine Grade Stainless Steel face plate Fitted with a Sealed Perspex Camera Hole and rear Mounting Studs to allow you to fit your own Camera Touch Switch operation Vertical or Horizontal orientation Blue LED Night illumination Optional Surface Mounting Kit is available 130mm Wide 264mm High 37mm Depth Model DP5 FLUSH MOUNT Standard Size Fitted with intelli...

Page 4: ... for DP3 and DP5 Door Phones You can alternatively use one of our Surface Mounting Kits which provides a Rain deflector See below SURFACE MOUNTING KITS Stainless Steel 304 Surface Mounting Kits are available for all Model DP2 to DP5 Door Phones so that your Door Phone can be mounted onto a wall surface rather than into it Two separate surface mounting kits are available to cater for the different ...

Page 5: ...e Volume of the Door Phone can be increased or decreased via the supplied program The Hang Up tone detection circuit will automatically terminate the Intercom call after the user hangs up If you have a LOCK MECHANISM fitted you can open a gate or door lock during a call to allow your visitor to enter by simply pressing on your telephone keypad LOCK RELAY 2 If you use the SECOND LOCK CONTROL FACILI...

Page 6: ...s to your Network Double Click the Icon to open the program Once the program has loaded Click for IP Address After a short delay the program will then display the IP Address Gateway Address and Subnet Mask of DS SIP The Password is root Enter the Password and then Click Login to Enter the Advanced Settings area This is where you can set up the SIP settings of the device SIP Parameter Setup Refer t...

Page 7: ...o the wall surface before re attaching the Door Phone with the securing screw Model DP2 5 DOOR PHONES Our DP2 DP5 are by default designed for Flush Mounting or they can all be Surface Mounted onto your wall surface using the appropriate Surface Mount Kit SMK Wall Mount Screws are supplied with all units AUDIO POWER CONNECTION Audio Connection The Centre 2 Pins of the Door Phone Socket are the Audi...

Page 8: ... OPENED at any time by calling the DS SIP Extension Number and pressing The Door Gate Lock will remain UNLOCKED for 15 seconds can be 01 99 secs You do not need to receive a call from the Door Phone first LOCK 2 RELAY FACILITY To OPEN the ALTERNATIVE Door Gate Lock after answering a call from your DOOR PHONE you need to press 2 on your telephone The lock will remain open until you HANG UP your tel...

Page 9: ...rated at 12V 1A The polarity of the Relay connection wires is not important Lock 1 should connect to the Brown and Orange terminals Lock 2 or Device 2 should connect to the Blue and White terminals NOTE Do not use the supplied DS SIP Controller 12V plug pack to also provide 12V power for the lock as this may cause damage to DS SIP You must use a separate 12V source with a maximum rating of 12V 1A ...

Page 10: ...tion Should you encounter one of these problems you will need to make slow careful adjustments in one direction or the other until speech can be heard in both directions and without distortion The balance POT is located on the back of DOOR PHONE under a small 3mm removable black plastic plug It should be adjusted using a small flat blade screwdriver IMPORTANT NOTES If you need to adjust the Pot 1 ...

Page 11: ...nouncement Note and cannot be used to terminate a call 2 AFTER A FIXED PERIOD OF TIME DS SIP will terminate an Intercom call after a programmable length of time The default connection time for DS SIP is 99 seconds You can change the Maximum Page Call Duration for any period of time between 10 99 seconds in Programming Mode These are back ups in case any of the above methods fails to take place DS ...

Page 12: ...e by Closing as soon as the Intercom is Triggered then you should enter a value of 01 99 in this area this value is the time in seconds that the Relay will remain closed AFTER HANG UP This facility will allow you to for example to control a Video Recorder and where the Video Recorder remains recording for 01 99 seconds after Hang Up Relay 1 Closure Time To Change from the Default Setting in progra...

Page 13: ...DS SIP switch is connected DS SIP switch will Answer after 1 ring you should hear 1 beep After the beep press you should hear 3 beeps This will take you into program mode 2 Change the settings as per the details on Pages 11 12 You will hear a single beep after each correct entry 3 Hang Up when Programming is complete Maximum Call Time To Change from the Default Setting in programming Mode Press 3x...

Page 14: ...f used 2 Set the Hot Line Number Go into the Phone 1 Menu Enter Phone 1 Then Enter Your Extension Number User Name Password Set to Hot Line and enter Number Then Scroll Down to the Bottom of the Page and Then You MUST Click When complete You MUST Click Reload See Above 1 B 4 Save A B 2 3 4 3 2 A ...

Page 15: ...ter the SIP Menu Enter Here Your SIP Server IP Address Make sure the Send Registration Request with Expire Time Is ticked It should only be unticked for a direct peer to peer IP connection Then Scroll Down to the Bottom of the Page You MUST Click 1 2 3 4 Save SIP Settings C 4 ...

Page 16: ...Changing from DHCP to Static IP Go into the Settings Menu Enter Settings Menu Deselect DHCP Here Enter Static IP Settings Here or Here Scroll Down to the Bottom of the Page You MUST Then Click 1 2 3 4 Save and Reload D ...

Page 17: ...nd Output port gain are set by default at 0 You can Decrease the Gain down to 12db or Increase the Gain up to 18db For Speaker Volume change the Output Gain For Microphone Volume change the Input Gain Then Scroll Down to the Bottom of the Page You MUST then Click If you do not need to make any further changes go to Section G and Reload Otherwise your changes will not be effected 1 2 3 save ...

Page 18: ...nloading the ATA User Guide Go into the Users Guide Menu Leave the Default Setting Unchanged Reset and execute Main Application Now Click There will be a short delay while the ATA resets itself Reset Select the Users Guide Menu A PDF User Guide will then download to your PC G H ...

Page 19: ...Natcomm Page 19 NOTES ...

Page 20: ...out the nature of the problem The Manufacturers obligation is solely to repair or replace the product The product may be replaced at the discretion of the Manufacturer The warrantor is not liable for any incidental or consequential damages due to such defects This Warranty shall not apply to any unit which has been subject to alteration modification abuse negligence accident external voltage light...