Page 5
Natcomm
WIRING CONNECTION
4 wires are required for connection of
DP1
and the DS Model Controller
that it will be used with it. of DP1. These wires are connected to DP1
using a Phoenix Plug and Socket on the rear of DP1.
*** It is preferable to use solid core telephone cable, such as CAT5.
*** Polarity of these wires is not important
but connection points are.
4 WIRE CONNECTION – Polarity in not important:
Using CAT5 cable or similar solid core cabling, you should connect the
Centre 2 pins (4 & 5) of the Door Phone RJ Connector on the Door
Station Controller as above and Pins 3 & 6 of the Door Phone RJ
Connector to the outer 2 terminals of the Phoenix connector located on
the rear of
DP1
. See page 6.
An interface unit with screw terminals is supplied with all Door Station
Controllers that provides a convenient means of connecting the solid
core cable to
DP1
and also power to any locks that may be used. If using
this supplied interface box, the screw terminals connecting to the RED
and GREEN wires should be connected to the centre terminals of the
Phoenix connector on the rear of the
DP1
unit and in the case of a 4 wire
connection the BLACK and YELLOW wires connected to the outer two
terminals of the Phoenix connector.
Polarity of these wires is not important but correct connection is.
The LED on the DOOR PHONE should then switch ON as soon as power
is applied to the DS CONTROLLER.
Where Two Door Phones are to be used, they should both connect to
the same terminals of the interface box (ie: parallel connection) as above.
Detailed information concerning LOCK CONTROL is provided within the
User Guide supplied with your DOOR STATION CONTROLLER.