background image

SET UP

A. To fill the Simulated Bladder

1. 

Hang the fluid administration set 18" above the simulator. Use Fluid Supply Stand 

(LF01022U shown, sold separately) or similar device. 

Note: 

Hanging the fluid administration set higher increases the water pressure and may 

cause leaking.

2. 

Close the slide clamp on the tube of the fluid administration set.

3. 

Squeeze open the top of the bag and fill with water. (To extend the useful life of your 

simulator, Nasco recommends distilled water.)

4. 

Connect the quick disconnect fittings of the administration set and simulator tubing.  

(See figure 1.)

5. 

Open the slide clamp on the administration unit and the pinch clamp on the simulator 

drain tube.

6. 

Allow water to flow through the simulator until it exits the drain tube. Close pinch clamp. 

(See figure 2.)

 The system is now filled with water and pressurized.

Figure 2

Figure 1

4

Actual product may vary slightly from photo. Nasco reserves the right to change product color, 

materials, supplies, or function as needed.

SET UP

A. To fill the Simulated Bladder

1. 

Hang the fluid administration set 18" above the simulator. Use Fluid Supply Stand 

(LF01022U shown, sold separately) or similar device. 

Note: 

Hanging the fluid administration set higher increases the water pressure and may 

cause leaking.

2. 

Close the slide clamp on the tube of the fluid administration set.

3. 

Squeeze open the top of the bag and fill with water. (To extend the useful life of your 

simulator, Nasco recommends distilled water.)

4. 

Connect the quick disconnect fittings of the administration set and simulator tubing.  

(See figure 1.)

5. 

Open the slide clamp on the administration unit and the pinch clamp on the simulator 

drain tube.

6. 

Allow water to flow through the simulator until it exits the drain tube. Close pinch clamp. 

(See figure 2.)

 The system is now filled with water and pressurized.

Figure 2

Figure 1

4

Actual product may vary slightly from photo. Nasco reserves the right to change product color, 

materials, supplies, or function as needed.

HC190001INM4.indd   7-8

12/20/18   9:16 AM

Summary of Contents for Life/form LF00856U

Page 1: ...HEALTHCARE FemaleCatheterization Simulator LF00856U INSTRUCTION MANUAL ...

Page 2: ...imulator almost as it would injure or cause pain to a patient Note To avoid the possibility of leakage make sure to use a 16 French Foley catheter supplied with the simulator LIST OF COMPONENTS A Life form Female Catheterization Simulator B Fluid Administration Set C Plastic Positioning Pad D 16 French Foley Silicone Catheter E Life form Simulator Lubricant 2 oz F Small White Towelette G Obstructi...

Page 3: ...water To extend the useful life of your simulator Nasco recommends distilled water 4 Connect the quick disconnect fittings of the administration set and simulator tubing See figure 1 5 Open the slide clamp on the administration unit and the pinch clamp on the simulator drain tube 6 Allow water to flow through the simulator until it exits the drain tube Close pinch clamp See figure 2 The system is ...

Page 4: ...ion will require heavy lubrication Do this by inserting the lubricated catheter about half way then remove and relubricate several times before inserting the catheter fully Figure3 Figure4 GENERAL INSTRUCTIONS FOR USE Catheterization Procedure Note To avoid the possibility of leakage be sure to use a 16 French silicone Foley catheter supplied with simulator 1 Position the plastic pad between the l...

Page 5: ...n stains from simulator Simply apply to soiled area and wipe clean with a soft cloth or paper towels B Storing the Simulator Do not store simulator for extended periods of time with water in the unit Before returning simulator to the case drain as much liquid as possible from the bladder 1 Open both tubing clamps Drain the simulator by holding it upside down and high in the air 2 Allow the water t...

Page 6: ...ining Models Set LF00901U Prostate Examination LF00906U Ostomy Care LF00957U Enema Administration LF00980U Advanced Breast Exam LF01029U Cath Ed 1 and Cath Ed 2 Set LF01035U Infant Male Female Catheter Trainer LF01038U Episiotomy Suturing Set LF01062U Pelvic Normal Abnormal LF01068U Cervical Dilatation and Effacement Simulators LF01069U Cervical Effacement LF01070U Birthing Station LF01084U Sigmoi...

Reviews: