The ideal 

manikin for all 

OBRA required 

training.

HC18000028INM23.indd   1

11/16/18   9:23 AM

Summary of Contents for Life/form Basic GERi LF04040U

Page 1: ...01U LF04030U LF04003U LF04005U Light LF04115U LF04116U LF04117U LF04118U LF04119U Medium KERi LF04021U LF04020U LF04022U LF04023U LF04026U Light LF04120U LF04121U LF04122U LF04123U LF04124U Medium The ideal manikin for all OBRA required training HC18000028INM23 indd 1 11 16 18 9 23 AM ...

Page 2: ...HC18000028INM23 indd 2 11 16 18 9 23 AM ...

Page 3: ...manikin easy to use and care for while teaching basic patient care techniques so please familiarize yourself with this manual before using the manikin for training Five year warranty Actual product may vary slightly from photo Nasco reserves the right to change product color materials or function as needed Main Features on Every Basic Complete Advanced Auscultation and Advanced Auscultation GERi a...

Page 4: ... Basin SB14936U Stomach Reservoir Bag LF04098U Bladder Reservoir Bag LF04095U Bladder Reservoir Pressure Sleeve LF04097U 16 FR Foley Silicone Catheter LF01127U 140 cc Syringe Enema Reservoir Bag LF04096U Serial number located on back of right shoulder ADDITIONAL FEATURES Includes all of the main features of Basic GERi KERi with the addition of internal fluid reservoirs Gastrostomy procedures lavag...

Page 5: ...79U Light LF04127U Medium Electronic Control Unit LF01096U Sphygmomanometer LF01073U 6 AA Batteries Serial number located on back of right shoulder ADDITIONAL FEATURES Includes all of the main features of Basic and Complete GERi KERi with the addition of right and left IV and BP arms Right IV training arm has a shoulder intramuscular injection site and features replaceable skin and veins that roll...

Page 6: ...nd Dual Headpieces LF01144U Remote Control with LCD Display LF01148U 2 AA and 2 AAA Batteries Alcohol Pads 50 8 Sheets of Green and Blue Circle Stickers 2 Laminated Key Cards Serial number located on back of right shoulder ADDITIONAL FEATURES Includes all the main features of Complete GERi KERi with the addition of auscultation torso SmartScope and remote Six anterior heart sites with 12 heart con...

Page 7: ...r 2 Fluid Supply Bags 500 ml each with 2 Clamps 3 cc Syringe 22 ga Needle Butterfly Set White 2 ply Towel 2 Left Blood Pressure Training Arm LF04079U Light LF04127U Medium Electronic Control Unit LF01096U Sphygmomanometer LF01073U 6 AA Batteries SB10828U SmartScope with Single and Dual Headpieces LF01144U Remote Control with LCD Display LF01148U 2 AA and 2 AAA Batteries Alcohol Pads 50 8 Sheets of...

Page 8: ...dure to disassemble See Figure 1 Figure1 Legs The legs attach to the body at the hips by bending the legs backward approximately 150 so the feet are near the shoulders and the keyholes are aligned See Figure 2 Figure2 Head To attach the head position the head facing back wards and align the keyholes Press down and turn head 180 so it is facing forward Reverse the proce dure to disassemble Joints A...

Page 9: ...ethra behind the genital insert 2 Ensure the cloth pressure sleeve is in place over the simulated bladder reservoir bag and the hook and loop fastener on the pressure sleeve is attached to the hook and loop fastener on the genital track 3 Fill the 140 cc syringe supplied with water Lubricate the end of the syringe s administration tube and insert though the urethra at least 7 8 SeeFigure7 4 Depres...

Page 10: ...damage to the simulator and void the warranty PROSTATE EXAMINATION Available with Complete Advanced Auscultation and Advanced Auscultation GERi KERi The male genital insert also includes the capability for digital rectal prostate palpation SeeFigure9 The prostate gland represents stage B progres sion of prostatic cancer A discrete hard nodule is palpable in the upper right quadrant simulating a be...

Page 11: ...osition 4 Using a facility supplied enema kit lubricate the applicator liberally and gently insert through the anus Note Use water ONLY when administering an enema Figure11 5 To simplify cleanup you may choose to leave the applicator in place while positioning the manikin to drain or remove applicator and position the manikin over a drainage basin The enema reservoir will drain via gravity as soon...

Page 12: ...omy site with warm water and a soft cloth prior to storing the manikin Removal of the internal stoma reservoirs can be achieved by 1 Removing the genitalia and reaching through the genital cavity The reservoir bags are attached to the underside of the stomas 2 To remove pull the reservoir fittings down and disconnect from the stomas Then pull the reservoir bags from the hook and loop attach ments ...

Page 13: ...ber with the lumen being the approximate size of an adult human vein SeeFigure18 INJECTABLE TRAINING ARM Available on Advanced and Advanced Auscultation GERi KERi or as a modular or add on to all other models CAUTION PRODUCT CONTAINS DRY NATURAL RUBBER 5 To remove the stomach rotate the head back ward 180 to align the keyholes in the neck 6 Gently pull up head to expose three tubes with the stomac...

Page 14: ...ssurized Be sure to leave the clamp on IV Bag A open The arm is ready to practice drawing blood Synthetic blood can be drawn anywhere along the pathway of the vein B Preparing the Arm for Intravenous Infusions 1 Start with an empty unpressurized arm Close the clamp at the end of IV Bag A and then fill with distilled water 500 cc maximum Hang IV Bag A not more than 18 45 72 cm above the arm 2 Ensur...

Page 15: ...v itational force on the fluid to facilitate flow 4 If a venous system clog is suspected try using a large 50 cc syringe to force distilled water through the tubing 5 Check the venous system tubing for kinks First lubricate the outside of the arm skin generously with Ivory liquid dishwashing detergent Peel the skin back to the knuckles being careful NOT to remove the skin from the fingers Examine ...

Page 16: ...t in the wrist GENERAL INSTRUCTION FOR USE Installing the Batteries 1 Take the Blood Pressure Electronic Control Unit out of the box and turn it over placing it face down onto a padded work surface 2 Locate the Open compartment on the back of the panel where the batteries are to be installed CAUTIONS 1 This synthetic blood is specially formulated to be compatible with the self sealing veins and pl...

Page 17: ...LIC pressure menu will display in the Electronic Control Unit window See Figure 28 3 Use the up or down arrow keys located to the right of the menu button to adjust the systolic pressure 4 Press the Menu key a second time 5 The Set DIASTOLIC pressure menu will display in the Electronic Control Unit window See Figure 29 6 Use the up or down arrow keys located to the right of the menu button to adju...

Page 18: ... the GAP Key to the right of the MENU Key 2 Press the GAP Key to set the function on Y Yes or off N No 3 When the key is pressed a message will briefly appear that the auscultatory gap is enabled or disabled 4 The Main display will show AGap Y or ON SeeFigure33 or AGap N or OFF Setting the Volume The arrow keys also control the volume of the sounds present in the arm 1 From the main menu press the...

Page 19: ...ey from the Systolic Correction window to change to the Diastolic Correction window See Figure 35 Preparing Your Sphygmomanometer for Use with Blood Pressure Simulator In the event the supplied sphygmomanometer would cease to operate any standard sphygmo manometer can be adapted for use with the blood pressure simulator It is recommended that a child size cuff continue to be used 1 Disconnect the ...

Page 20: ... LCD display will read HS 01 LS 01 20 THE AUSCULTATION SIMULATOR AND SMARTSCOPE WITH WIRELESS REMOTE CONTROL The auscultation feature duplicates heart and lung conditions selected by the instructor via wireless remote control with LCD Display Palpation is required to correctly identify the auscultation locations Heart Sounds are detected at 6 anterior locations with 12 heart conditions 01 Normal 0...

Page 21: ...he Blood Pressure Simulator remote control and SmartScope equipped with the Auscultation feature prior to storing your equipment for future use 21 Listening to Selected Heart and Lung Sounds 1 Follow the instructions above to activate remote control SmartScope and select desired sounds 2 Place the earpieces of the SmartScope in ears angled in a forward position 3 Place the diaphragm of the SmartSc...

Page 22: ...stolic presystolic murmurs loud1stsound 5 Holosystolic Murmur Normal Normal Normal Normal Patienthasmitralregurgitation frequent prematureventricularcontractions Murmur iscrescendo decresendowithlatepeaking SoftS3inmiddiastole 6 Midsystolic Murmur Normal Normal Normal Normal Patientwithhypertrophiccardiomyopathy hasamurmurthatbeginsafterS1andends beforeS2 7 S3 Gallop Normal Normal Normal Normal Pa...

Page 23: ...FineCrackle FineCrackle 6 Coarse Crackle CoarseCrackle CoarseCrackle CoarseCrackle CoarseCrackle 7 Ronchi Ronchi Ronchi Ronchi Ronchi 8 Stridor Stridor Stridor StridorLower Volume StridorLowerVolume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular NormalVesicular NormalVesicular 11 Bronchial Bronchial Bronchial NormalVesicular NormalVesicular 12 Pul...

Page 24: ...Female Wig LF04061 N U Hip LF03136U Constricted Pupil LF03135U Dilated Pupil LF04046 N U Foot Right LF04069 N U Ankle LF04060 N U Hip Joint Left LF04096U Enema Reservoir Bag LF04095U Bladder Reservoir Bag LF04061 N U Hip LF04047 N U GERi Upper Torso LF04048 N U GERi Lower Torso for Complete Advanced Auscultation LF04070 N U KERi Upper Torso LF04082 N U KERi Hip Injection Site LF04073 N U KERi Lowe...

Page 25: ...screw 1 31 2 screw post with screw 2 41 2 screw post with screw 2 5 screw post with screw 6 washers 24 anodized screws Complete Manikin Hardware Set LF04072U 1 73 4 nylon bar 2 washers 2 1 4 slotted screws 31 4 screw post with screw 21 2 screw post with screw 21 4 screw post with screw 21 4 screw post with screw 13 4 screw post with screw 13 4 screw post with screw 1 washer Complete Single Arm Har...

Page 26: ...nd 5 x 8 13 x 20 cm base 5 16 steel hooked rod Sh wt 4 lbs LF01022U Foley Catheter 16 FR 5 cc LF01127U Each Sh wt 0 25 lbs LF01128U Pkg of 10 Sh wt 0 63 lbs Foot Right Sh wt 1 75 lbs LF04046 N U Foot Left Sh wt 1 75 lbs LF04045 N U Genitalia Basic Male Sh wt 0 69 lbs LF04109U Genitalia Basic Female Sh wt 0 69 lbs LF04110U Genitalia Complete Advanced Auscultation Male Sh wt 4 25 lbs LF04075 N U Gen...

Page 27: ...wt 0 88 lbs LF00985U Nasco Cleaner UsetoremovestubbornstainsfromLife form simulators 12 oz bottle Sh wt 0 88 lbs LF09919U Replacement Blood Pressure Cuff Sh wt 1 25 lbs LF01073U Shoulder Injection Site Sh wt 0 25 lbs LF04051 N U Shoulder Left Sh wt 0 50 lbs LF04055 N U Shoulder Right Sh wt 0 50 lbs LF04064 N U Shoulder Joint Right Sh wt 0 31 lbs LF04063 N U Shoulder Joint Left Sh wt 0 31 lbs LF040...

Page 28: ...h Interactive ECG Simulator LF01400U LF01280U Copyright 2010 HC18000028INM23 ONLINE NascoHealthcare com EMAIL lifeform enasco com PHONE 1 800 431 4310 ADDRESS 901 Janesville Ave Fort Atkinson WI 53538 HEALTHCARE LF01420U Actual product may vary slightly from photo Nasco reserves the right to change product color materials supplies or function as needed HC18000028INM23 indd 28 11 16 18 9 25 AM ...