Figure 7

A.

C.  Intravenous Infusions

1.  Begin with a fully pressurized arm. See procedure A under 

General Instructions for Use.

2.  Select the appropriate intravenous infusion needles or 

butterfly included. Nasco Healthcare recommends small 

gauge needles 20-25 gauge. 

3.  Make sure the arm is palm down and the clamps on Bags A 

and B are closed.

4.  Simulate cleansing the injection site with distilled water, 

alcohol, or iodine solution. 

5.  Insert the IV needle or butterfly into a vein. Flashback will 

indicate proper insertion.

6.  Attach the needle or butterfly to the tubing from the infusion 

solution (not supplied) or fluid supply bag C (sold separately) 

with the latex adapter if needed. (See Figure 7 and inset.)

7.  Open the clamps on fluid supply bag B. 

C.

B.

8

Summary of Contents for LF01271

Page 1: ...Multi Venous IV Injection Arm LF01271 Light LF01272 Medium INSTRUCTION MANUAL ...

Page 2: ... will provide you with long trouble free usage the skin and veins can be easily removed and replaced when needed providing literally a brand new arm The life of the replaceable skin and veins will be prolonged by utilizing smaller needle sizes such as 20 to 25 gauge However if instruction with larger needle sizes is required this can be done the skin and veins will merely need to be replaced soone...

Page 3: ...EDIUM B 3 cc Syringe with Needle C 12 cc Syringe with Needle D Case E 2 Fluid Supply Bags F Infusion Butterfly G Pinch Clamp H 2 Small Towels I Infusion Needle J 2 Pint Bottles with Blood Powder K Skin Sealant L Arm Stand included but not pictured D B C D E F G H I J K J A 3 ...

Page 4: ...human vein The lumen changes diameter in the arm to simulate rolling or disappearing veins This vascular structure has inlet tubing and outlet tubing at the shoulder and it is via these tubes that the venous system is filled Thus the techniques of blood drawing and starting intravenous infusions may be practiced on the Multi Venous Injection Arm Venous Channels Beneath the Skin 8 Fluid Lines Subcu...

Page 5: ...8 above the level of the arm See Figure 1 and inset Fluid Supply Stand shown sold separately 3 Attach the fitting end of the fluid supply bag A tubing to one of the shoulder tubes Make sure the arm is palm down at this point See Figure 2 Note Connecting the fluid supply bag to the shoulder tube may require a small amount of water soluble lubricant heating the shoulder tube end in the palm of a war...

Page 6: ...open the clamp on bag A to allow some blood to pass through and to remove any remaining air that is trapped in the system See Figure 5 Note It may be necessary to swap the positions of the fluid supply bags A and B during the filling process in order to prevent bubbles in the tubing If bag A runs out of blood before the arm is fully prepped simply remove it from its hanging position and replace it...

Page 7: ...pply Bag A The arm is now ready to perform injections or withdrawals along any of the 8 fluid lines present in the arm Nasco Healthcare recommends the use of small diameter needles for these procedures 20 to 25 gauge Use only distilled water to prep the injection sites and as an injection A realistic flashback will occur when the vein has been properly punctured See Figure 6 Figure 6 7 ...

Page 8: ...re the arm is palm down and the clamps on Bags A and B are closed 4 Simulate cleansing the injection site with distilled water alcohol or iodine solution 5 Insert the IV needle or butterfly into a vein Flashback will indicate proper insertion 6 Attach the needle or butterfly to the tubing from the infusion solution not supplied or fluid supply bag C sold separately with the latex adapter if needed...

Page 9: ...solution or fluid supply bag C Proof of proper procedure will be evidenced by the flow of fluid from the infusion solution or fluid supply bag C See Figure 8 Note This procedure may dilute your simulated blood solution Figure 8 A C B 9 ...

Page 10: ...nt since the distilled water cannot be drained but must evaporate from the arm Synthetic blood must NEVER be used for injections E Intradermal Intracuetaneous Injections Use a 3 cc syringe with a 25 gauge needle for this procedure Internal Structure of the the arm features three locations All are located on the outer aspect of the upper arm See Figure 10 If fluid is properly injected a characteris...

Page 11: ...the shoulder and draining it into a sink or basin 8 Remove the clamps from the fluid supply bag tubing as they can cause permanent kinks and restrict fluid flow B Cleaning the Simulator 1 Wash the outside of the arm with mild liquid detergent and water C Maintaining the Simulator Nasco Vein Tubing Sealant Kit LF01099U will extend the useful life of the tubing Note Nasco Vein Tubing Sealant cannot ...

Page 12: ...stem Burred needles will cause permanent damage Use smaller needles 20 to 25 gauge 4 DO NOT allow blood to dry on simulator it may stain the skin 5 Use only 500 cc of infusion fluid as a larger amount will also increase the pressure of the venous system resulting in leaks 6 DO NOT clean the simulator with solvents or corrosive material as they will damage it 7 Newsprint similar printed paper or pl...

Page 13: ...ional video 4 Check for air bubbles Make sure you purge the arm of air bubbles Gradually flush the system with synthetic blood by slowly opening the supply clamp Allow some blood to pass through the system until the air bubbles have been eliminated in the drain bag Close the clamp on the supply bag and then turn the arm over so it is palm up Slowly open the clamp to allow some blood to pass throug...

Page 14: ...ant LF01022 Fluid Supply Stand LF01099 Vein Tubing Sealant Kit LF01104 IV Arm Skin Vein Replacement DVD FREE LF01105 IV Arm Set Up Troubleshooting DVD FREE LF01274 Replacement Skin Light LF01275 Replacement Skin Medium LF01276 Replacement Skin Dark LF01277 Vein Replacement Kit LF01130 Fluid Supply Bag LF01022 Fluid Supply Stand Not available outside the United States 14 ...

Page 15: ...e IV Arm Light LF00952 Injection Training Model Light LF00958 Pediatric IV Arm LF00961 Intramuscular Injection Simulator LF00995 Arterial Puncture Arm LF01007 IV Foot LF01008 Intradermal Injection Simulator LF01139 Advanced IV Hand Light LF01162 Vebatech IV Trainer Light LF01184 Venatech IM SubQ Simulator Light LF03637 Infant IV Arm LF03636 Infant IV Leg 15 ...

Page 16: ...Nasco Healthcare 16 Simulaids Drive Saugerties NY 12477 1 833 NASCOHC 627 2642 info nascohealthcare com www nascohealthcare com NC30732 IM 601003 03 21 2021 Nasco Healthcare ...

Reviews: