1. THE ELECTRIC HEATER SET INCLUDES:
1. Heater with control unit
2. Fastening plates and fastening screws
3. Temperature sensor
4. Control unit
5. Installation and operating instructions
2. BEFORE INSTALLATION:
Check on the following:
– Make sure the capacity of the heater (kW) corresponds to the size of the steam room (m
3
).
– Table 1 shows the heater types that correspond to various size saunas.
– If the steam room has any non-insulated brick, tile or glass surfaces, 1.5 m
3
of space must be added
to the size of the steam room for every square-meter of such surfaces. Based on the result, choose
the heater with the required capacity shown in table 1.
When choosing a heater, strictly adhere to the steam room space shown in table 1.
Table 1. Installation information for heater
– The minimum height of the steam room and minimal safety clearances are
shown in table 1.
– Make sure that the surface onto which the fastening plates are being screwed is sufficiently strong.
Thin boarding is not sufficient. The surface can be reinforced with a supporting framework under
the boarding or reinforcing boards on top of the wall, which is connected to a wall framework.
- The floor under the sauna heater must be heat resistant. Hot pieces of the stones might drop on
the floor from the heater and cause fire risk.
ONLY ONE ELECTRIC HEATER MAY BE INSTALLED IN EACH SAUNA ROOM.
Heater model
Capacity
Sauna room
Minimal safety clearances to the heater
Quantity
of stones
Connection *)
Volume
Height
on the
sides
at the
front
to the ceiling
to the floor
5-10 cm
400 V
3N
Fuses
min max
min
A **)
B **)
C **)
D **)
kW
m
3
m
3
mm
mm
mm
mm
mm
kg
mm
2
A
STYLE 6,8 kW
6,8
5
8
1900
50
50
900
30
60
5x1,5
3x10
STYLE 9,0 kW
9
8
14
1900
50
50
900
30
60
5x2,5
3x16
**) See figure 1
*) Connected with rubber cable, type H07RN-F
or corresponding cable
TECHNICAL DATA:
- width 360 mm
- depth 360 mm
- height 1000 mm
- weight 26 kg
(without stones)
min 50
min 50
max 400
min 30
min 300
max 900
min 600
100
min 50
min 50