background image

 

INSTALLATION INSTRUCTIONS AND    

 

 

INSTRUCTIONS FOR USE

 

NARVI STONY SAUNA STOVES

GB

SAFETY DISTANCES

Before installing the sauna stove ensure the required safety distances to inflammable 
material are met. The safety distances of the sauna stove are 400 mm to the sides, 
250 mm to the rear and 1200 mm upwards. At the base, a concrete board of at least 
70 mm must be used. 

The Narvi Stony sauna stove must not be installed on top 

of an underfloor heating.

 If you are unsure please contact your local fire authority 

for guidance.

Inflammable construction parts, such as wooden 
walls, sauna seats etc.
1. Distance from the vertical surfaces of the sauna 
stove to unprotected wooden parts  400 mm to the 
sides, 250 mm to the rear and 1000 mm in front. 
(Fig. 1)

The protection must also be clear of the floor 
and the ceiling.

2. The safety distance mentioned in paragraph 
1 can, however, be reduced by half when “light-
single” protection is used. Single-light protection 
of this type can be made of a non-combustible, 
fibre-reinforced cement board of at least 7 mm 
dick or of a metal plate of at least 1 mm which 
has been fastened securely enough to the wall. 
A ventilation gap of at least 30 mm must be left 
between the wooden surface to be protected and 
the safety plate by using piping collars. (Fig. 2)

3. The safety distance in paragraph 2 can 
be further reduced to 100 mm when double 
protection is used.
Double protection can be made of two plates as 
described in paragraph 2 and, then a ventilation 
gap of at least 30 mm must be left between the 
wall and the plates. (Fig. 3)

Fig.   1

Fig.   2

30 mm ventilation gap

1 mm metal plate or

7 mm non-combustible,

fibre-reinforced,  

cement board

30 mm ventilation gap

1 mm metal plate or

7 mm non-combustible,

 fibre-reinforced  

concrete board

Fig.  3

Summary of Contents for STONY 18

Page 1: ...I STONY NARVI STONY PAIGALDUS JA KASUTUSJUHEND NARVI STONY RENGIMO IR NAUDOJIMO INSTRUKCIJA NARVI STONY UZST D ANAS UN LIETO ANAS INSTRUKCIJA NARVI STONY INSTRUKCJA MONTA U I OBS UGI NARVI STONY BESZE...

Page 2: ......

Page 3: ...a eteen 1000 mm Kuva 1 Suojauksen tulee olla irti my s lattiasta ja katosta 2 Kohdassa 1 mainittua suojaet isyytt voidaan kuitenkin pienent puolella kun k ytet n ns kevytt yksinkertaista suojausta T l...

Page 4: ...toon on v hint n 1200 mm ei erityist katon suojausta tarvita Jos et isyys on pienempi kuin 1200 mm valitaan katon suojaustapa kohdista 1 3 Kuva 6 Lattian suojaus kiukaan edess Palava aineinen lattia t...

Page 5: ...on s t jalat joiden avulla kiuas asennetaan suoraan Varmista asennuksen yhteydess ett kiuas on tukevasti alustallaan ja asennettuna siten ett t ss ohjeessa mainitut suojaet isyydet ovat oikeat Kiukaa...

Page 6: ...nnen kiukaan l mmityst on aina puhdistettava arina ja tyhjennett v tuhkalaatikko L mmitys aloitetaan pienell m r ll puita jotka sytytet n puiden yl pinnasta Kun puut palavat kunnolla lis t n tulipes n...

Page 7: ...och tak 2 Skyddsavst ndet enligt punkt 1 kan emellertid minskas med h lften d ett s kallat enkelt l tt skydd anv nds Ett s dant enkelt l tt skydd kan tillverkas av minst 7 mm tjock obr nnbar fiberf r...

Page 8: ...mm beh ver taket inget s rskilt skydd Om avst ndet r kortare n 1200 mm v ljs s ttet att skydda taket enligt punkterna 1 3 Bilden 6 Golvskydd framf r bastuugnen Golvet av br nnbart material skall skyd...

Page 9: ...t f r djupt i r kr ret eftersom detta kan f rs mra draget Springan mellan anslutningsr ret och r kr ret skall t tas med t ex isolering F r att du smidigt skall kunna st lla ugnen i r tt l ge medf ljer...

Page 10: ...pv rmningen b rjas med en liten m ngd ved som t nds p vedens vre yta N r veden brinner ordentligt tills tts ytterligare ved upp till ca 2 3 av eldstadens h jd tg ngen till luft som beh vs f r att vede...

Page 11: ...the floor and the ceiling 2 The safety distance mentioned in paragraph 1 can however be reduced by half when light single protection is used Single light protection of this type can be made of a non...

Page 12: ...special protection of the ceiling is necessary If the distance is less than 1200 mm the protection method for the ceiling is selected from paragraphs 1 3 Fig 6 Protection of the floor in front of the...

Page 13: ...delivery Also included in the delivery is a 200 mm flue pipe connector for connection of the sauna woodburning stove to a rear flue pipe When connecting the sauna woodburning stove to the flue from t...

Page 14: ...ash pan must be emptied Start by lightning a small quantity of wood on the upper surface of the wood When the wood is burning properly add more wood to 2 3 of the height of the firebox To burn proper...

Page 15: ...NARVI STONY RU 400 250 1200 1000 70 Narvi 1 400 250 1000 1 2 1 7 1 30 2 3 2 100 2 30 3 1 2 3 30 1 7 30 1 7...

Page 16: ...4 50 4 400 200 100 5 55 30 110 5 1200 1200 1 3 6 100 400 7 8 9 4 5 6 7 8 9...

Page 17: ...12 13 11 400 200 120 10 200 NARVI...

Page 18: ...122 115 1 2 NARVI NARVI 1 2 20 2 3 NARVI 100 400...

Page 19: ...da p randa ega lae vastu 2 Niinimetatud kerge hekordse isolatsiooni kasutamisel on lubatud v hendada punktis 1 nimetatud ohutuid vahekaugusi poole v rra Sellise isolatsioonikihi valmistamiseks v ib ka...

Page 20: ...alt punktidele 1 3 ja joonisele 6 P randa isoleerimine kerise ees Kerise ees paiknev s ttivast materjalist p rand tuleb isoleerida lehtmetalli t kiga mille servade kaugus kolde vasakust ja paremast nu...

Page 21: ...l riga on olemas kaks avaust mis paiknevad kerise peal ja selle tagak ljel Kasutamata j nud avaus suletakse tarnekomplekti kuuluva ummik rikuga Kerisekomplekti kuulub ka 200 mm pikkune hendustoru keri...

Page 22: ...uleb puhastada tuharest ja t hjendada tuhakast Kerist hakatakse k tma v ikese koguse halgudega mis s datakse pealtpoolt Kui need halud on korralikult p lema l inud on soovitatav lisada veel veidi puid...

Page 23: ...neturi susiliesti nei su grindimis nei su lubomis 2 Naudojant vadinam j lengv viensluoksn izoliacij leid iama suma inti 1 e punkte nurodyt atstum per pus Tokios izoliacijos sluoksniui paruo ti galima...

Page 24: ...br inyje pateikta informacija Grind prie krosnel izoliavimas Prie krosnel esan ias degias grindis reikia izoliuoti metaline plok te kurios kra tai nuo ugniakuro kairiojo ir de iniojo kamp b t ma iausi...

Page 25: ...vir uje ir galin je jos sienel je Nepanaudota d mtraukio prijungimo anga u dengiama dangteliu kuris yra krosnel s rangos komplekte Krosnel s rangos komplekte taip pat yra 200mm d m vamzdis kuriuo kro...

Page 26: ...per ilgesn laik malkos gerai i d i sta ir j dr gm s kiekis suma ja daugiau nei iki 20 K RENIMAS Prie pakuriant krosnel reikia pa alinti nuod gulius ir i kratyti pelenus Krosnel prad kite k renti nedi...

Page 27: ...1 000 mm 1 att ls Izol cija nedr kst aizskart gr du vai grieztus 2 Izmantojot t saukto vieglo vienk rt go izol ciju ir auts samazin t punkt 1 min tos dro os att lums uz pusi da izol cijas sl a pagatav...

Page 28: ...nktiem 1 3 un att lu 6 Gr das izol cija pirtskr sns priek No uzliesmojo a materi la gatavota gr da kura atrodas pirtskr sns priek ir j izol ar met la pl ksni kuras mal m kreisaj un labaj pus ir j b t...

Page 29: ...nosprostotu vilkmi Atveri starp d meni un d mvadu nepiecie ams nobl v t piem ram izmantojot nedego u miner lvati Standarta pieg d iek autas regul jamas k ji as ar kuru pal dz bu pirtskr sns tiek novie...

Page 30: ...n anas ir j not ra pelnu re is un j iztuk o pelnu kaste Pirtskr sns kurin ana tiek s kta ar nelielu paga u daudzumu aizdedzot t s no virspuses Kad s pagales ir k rt gi aizdegu s ir ieteicams pievienot...

Page 31: ...od og ani sufitem 2 Przy u yciu tzw lekkiej izolacji jednowarstwowej dopuszczalne jest zmniejszenie bezpiecznych odleg o ci wymienionych w pkt 1 o po ow Do wykonania takiej warstwy izolacyjnej mo na s...

Page 32: ...i Rysunkiem 6 Izolacja pod ogi przed kamionk Znajduj c si przed kamionk pod og z materia u palnego nale y izolowa przy pomocy kawa ka blachy stalowej kt rej odleg o kraw dzi powinna wynosi co najmniej...

Page 33: ...onie Niewykorzystany otw r pod czenia do komina zamyka si za lepk kt ra wchodzi w sk ad dostarczanego zestawu W sk ad zestawu wchodzi r wnie rura cz ca 200 mm do pod czenia do komina od ty u pieca W p...

Page 34: ...poni ej 20 OGRZEWANIE Przed ogrzewaniem kamionki nale y oczyszcza ruszt oraz opr ni szuflad na popi Ogrzewanie kamionki rozpoczyna si od palenia niewielkiej ilo ci polan rozpalonych z g ry Gdy polana...

Page 35: ...000 mm 1 bra A szigetel s nem rintkezhet sem a padl val sem a mennyezettel 2 Az gynevezett k nny egyr teg szigetel s haszn lata eset n az 1 pontban megnevezett biztons gi t vols gokat a fel re lehet c...

Page 36: ...elel en kell szigetel st v lasztani A padl szigetel se a k lyha el tt A k lyha el tt az ghet anyagb l k sz lt padl t f mlemezzel kell szigetelni A lemez sz leinek a k lyha bal s jobb sark n legal bb 1...

Page 37: ...tetej n s h tulj n tal lhat k A nem haszn lt furat a k szletben tal lhat t m t csavarral z r dik el Ugyancsak a k szlet tartalmaz egy 200 mm es sszek t cs vet amely seg ts g vel a k ves kemence h tulr...

Page 38: ...t s r tse ki a hamurekeszt A k lyha f t s t kis mennyis g f val kell kezdeni amit fel lr l kell meggy jtani Ha ezek fadarabok rendesen meggyulladtak hozz lehet m g rakni egy kev s f t hogy a t zt r k...

Page 39: ...ar ntr un singur strat distan ele de siguran men ionate la punctul 1 pot fi reduse la jum tate Pentru a preg ti un asemenea strat de izola ie pute i folosi dale din ciment rezistente la foc cu arm tur...

Page 40: ...elor 1 3 i figurii 6 Izolarea podelei din fa a sobei Dac podeaua din fa a sobei este realizat din material inflamabil aceasta trebuie izolat cu buc i de plac metalic ale c ror margini s fie la cel pu...

Page 41: ...Exist dou orificii pentru a conecta camera de ardere de co ul de fum care sunt localizate pe partea superioar i n spatele camerei de ardere Orificiile care nu se folosesc se inchid cu capace care intr...

Page 42: ...nivelul de umiditate va fi mai mic de 20 NC LZIREA nainte de nc lzirea sobei gr tarul pentru cenu trebuie cur at iar cenu a ndep rtat ncepe i s nc lzi i soba cu o cantitate mic de lemne de foc de esen...

Page 43: ......

Page 44: ...NARVI OY Yritt j ntie 14 FIN 27230 Lappi Finland Tel 358 0 207 416 740 Fax 358 0 207 416 743 www narvi fi...

Reviews: