The preset time has not run out yet, but you wish to switch on the sauna heater immediately.

1.  Depress the SET button -> the yellow LED flashes, and the remaining power-on time 

  will be displayed.

2.  Depress the + or - button as many times as is necessary to decrease the display reading to zero.

  -> the heater is switched on and the On/Off LED in the top left corner glows red. 

  During the preset time it will not be illuminated at all.

3.  Depress the SET button  -> the green LED flashes.

4.  Depress the SET button  -> the red LED flashes.

5.  Depress the SET button -> the heater remains switched on normally for the time indicated by the display.

 

5. TECHNICAL SPECIFICATIONS

Technical specifications

  •  Temperature range  

60 ºC–115 ºC

  •  Preset timing   

max. 24 h

  •  Power-on time   

max. 4 h

  5.2 Upper card

  •  enclosure class 

IPX4

  •  the control unit can be 

    installed either in the sauna 

    or in the dressing room

  5.3 Lower card

  •  voltage 

230 V 3N  50 Hz

  •  amperage 

16 A

  •  heater capacity 

max. 10.5 kW

  •  protection class 

IPX4

  •  overheating protection 

144 ºC

  •  fuse 

100mA

6. AIR EXCHANGE FOR THE STEAM ROOM: 

-   The air exchange in the steam room must be as efficient as possible, in order to guarantee sufficient 

  oxygen content and availability of fresh air. The air in the steam room should be changed 3-6 times 

  in an hour. It is recommended that the ventilation be realised in accordance with the HVAC designer’s plan
-   The fresh air is directed through a ca. 100-mm diameter duct. The outlet duct should be larger  in diameter 

  than the inlet duct. If the ventilation is mechanical, we recommend placing the inlet air valve in the ceiling 

  near the heater. Locate the temperature sensor at a sufficient distance from the inlet air valve!
 -   There must be a space of at least 1,000 mm between the temperature sensor and 

  the fresh air duct or 500 mm if the duct end can be turned.   

-  If the ventilation is natural, we recommend placing the inlet air valve on the side of the heater 

  or under it, either in the wall or in the floor.

-   It is important to introduce fresh air, so that the air mixes with the air and the steam. 
-   The exiting air should be exhausted from near the floor as far as possible from the incoming air. 

-   The air exhaust valve may be located under the sauna benches. 

-   The exiting air may be directed out of the steam room through the washroom,  for instance under the door. 

  There must be an approximately 100-150-wide slit between the door and the floor.

-  If you provide your sauna with a separate drying valve, place it in the ceiling of the steam room.

  (This valve shall be closed during the use of the sauna.) 

The remaining power-on time is only 15 minutes, but you wish to continue enjoying 

the sauna for longer than this

1.  Depress the SET button -> the green LED flashes, the remaining power-on time will still be displayed.

2.  Select the desired additional time by depressing the + button

3.  Depress the SET button -> the red LED flashes.

4.  Depress the SET button -> the heater will remain switched on for the time indicated on the display.

5.  Note!  After the desired period of time has been set, the green LED can be left flashing.

  The heater will then automatically return to its normal operating mode within about 1 minute.

Summary of Contents for Stonet 6kW

Page 1: ...NARVI STONET 6kW 9kW FI SE GB DE RU ASENNUS JA K YTT OHJE INSTALLATIONS OCH BRUKSANVISNING INSTALLATION AND INSTRUCTION MANUAL INSTALLATIONS UND BETRIEBSANLEITUNG VERSIO 10 2013...

Page 2: ......

Page 3: ...voja ei saa ylitt eik alittaa Taulukko 1 STONET kiukaan asennustiedot Saunan minimikorkeus on m ritelty taulukossa 1 samoin kuin minimisuojaet isyydet Varmista ett kiinnityslevyn ruuveille on riitt v...

Page 4: ...tila anturiin johdon voi katkaista sopivan mittaiseksi Kuva 1 STONET kiukaan suojaet isyydet Kuva 2 3 13 Ohjausyksik n asennus Ohjausyksikk voidaan asentaa saunaan tai saunan ulkopuolelle Ohjausyksikk...

Page 5: ...urioidu Kiukaan etuverkko on kaksiosainen Ylempi osa voidaan irroittaa kivien ladonnan helpottamiseksi alaosaan Kivien ladonnassa on huolehdittava ett vastukset eiv t taivu eik riitt v ilmankierto est...

Page 6: ...aansa siit pisteest miss se oli ennen katkoa Jos katko on yli 3 min kiuas menee pois p lt Asetusarvot s ilyv t aina muistissa s hk katkon pituudesta riippumatta 4 6 Asetukset Kun kiuas laitetaan p lle...

Page 7: ...k katkoissa Esiajastuksen aikana n yt ss n kyy aina j ljell oleva esiajastusaika Vikatilanteissa n yt ss voi n ky virhekoodi joiden merkitykset ovat seuraavat E01 Anturipiiri on avoin tai anturi puutt...

Page 8: ...alkaisijaltaan suuremmalla putkella kuin tuloilma Jos ilmanvaihto on koneellinen suositellaan tuloilmaventtiili sijoitettavaksi kattoon kiukaan l helle Huomioi l mp tila anturin et isyys tuloilmaventt...

Page 9: ...tai ole opastanut heille laitteen k ytt Lapsia on valvottava jotteiv t he leiki t ll laitteella Tarkista aina ennen kiukaan p lle kytkemist l ylyhuone V rin t ytetty kivitila aiheuttaa palovaaran Peit...

Page 10: ...f r varken verskridas eller underskridas Tabell 1 Installationsdata f r STONET aggregat Bastuns minimih jd samt minimis kerhetsavst nden anges i tabell 1 F rs kra dig om att f stunderlaget f r f stpla...

Page 11: ...till temperaturgivaren Du kan kapa ledningen till nskad l ngd Bild 1 Skyddsavst nd till bastuaggregatet STONET Bild 2 3 13 Installation av styrenheten Styrenheten kan installeras i eller utanf r bastu...

Page 12: ...att underl tta radandet av stenarna i den nedre delen Rada upp stenarna varsamt f r att inte skada yttermantelns ytbel ggning D du radar stenarna ska du se till att motst nden inte b gnar och att luf...

Page 13: ...tl ge och eventuell justering av den p kopplade tiden inverkar endast p den aktuella uppv rmningen D du trycker ned knappen SET b rjar den gula diodlampan blinka och det visas nollor i rutan Efter det...

Page 14: ...nskar att bastuaggregatet vid varje anv ndningsg ng h lls p kopplat i 2 5 timmar 1 Koppla p str mmen via knappen I O 2 Tryck ner knappen SET den gula diodlampan blinkar 3 Tryck ner knappen SET en and...

Page 15: ...meter Om ventilationen r maskinell rekommenderas det att inloppsluftventilen placeras i taket n ra bastuaggregatet Beakta temperaturgivarens avst nd fr n inloppsluftventilen Avst ndet mellan temperatu...

Page 16: ...br nns r Man f r bara kasta litet vatten 1 2 dl i s nder p bastuaggregatets stenar d det f r ngade vattnet r br nnande hett Detta aggregat r inte avsett att anv ndas av barn eller s dana personer vil...

Page 17: ...m room space shown in table 1 Table 1 Installation information for STONET heaters The minimum height of the steam room and minimal safety clearances are shown in table 1 Make sure that the surface ont...

Page 18: ...ivery 2 pcs 2 9 x 16 The wiring for the temperature sensor can be embedded Connect the sensor to the circuit plate as shown in Fig 2 1 Connect the end of the conductor the one with no connector in pla...

Page 19: ...the stones in the lower part Pile the stones carefully so as not to damage the exterior coating of the heater When piling the stones make sure that the resistors do not get bent and that the circulati...

Page 20: ...ing mode and any subsequent settings of the power on time will only affect the current heating session When the SET button is depressed the yellow LED will flash and an array of zeros will be displaye...

Page 21: ...tched off Find out the cause of the error 4 8 Examples The desired temperature in the sauna is about 100 C and the heater is desired to be switched on for 2 5 hours at a time 1 Switch on the power usi...

Page 22: ...et duct If the ventilation is mechanical we recommend placing the inlet air valve in the ceiling near the heater Locate the temperature sensor at a sufficient distance from the inlet air valve There m...

Page 23: ...the equipment if the person who is responsible for safety cannot supervise them or instruct them in the use of the equipment Children may not be left unsupervised and they should be supervised to make...

Page 24: ...belle 1 dargestellt wird Tabelle 1 Informationen zum Aufbau von STONET fen Die Mindesth he des Saunaraums sowie die Mindestsicherheitsabst nde werden in Tabelle 1 dargestellt Stellen Sie sicher dass d...

Page 25: ...an der Wand Das F hlerkabel kann eingesenkt werden Schlie en Sie den F hler am Stecker der Platine wie in Abb 2 1 gezeigt an Verbinden Sie das Kabelende ohne Stecker mit dem Temperaturf hler Das Kabel...

Page 26: ...eichtern Schichten Sie die Steine vorsichtig um den berzug des Au enmantels des Ofens nicht zu besch digen Beim Beladen der Steine muss daf r gesorgt werden dass die Heizwider st nde nicht verbogen we...

Page 27: ...erden Danach geht der Saunaofen in den normalen Betriebszustand ber und die sp ter vorgenommenen Einstellungen an der Einschaltdauer wirken sich nur auf die jeweilige Saunarunde aus Nach dem Dr cken d...

Page 28: ...ca 100 C und der Saunaofen soll 2 5 Stunden lang heizen 1 Schalten Sie mit dem I O Taster ein 2 Bet tigen Sie die SET Taste die gelbe LED blinkt 3 Bet tigen Sie die SET Taste erneut die gr ne LED bli...

Page 29: ...den normalen Betriebszustand zur ck 6 LUFTAUSTAUSCH IM SAUNARAUM Der Luftaustausch im Saunaraum muss so effizient wie m glich vonstatten gehen um ausreichend Sauerstoffgehalt und Frischluft zu gew hr...

Page 30: ...en k nnten verwendet werden Dies sollte nur unter Aufsicht oder Anleitung der f r die Sicherheit zust ndigen Person geschehen Kinder d rfen sich nicht ohne Aufsicht im Raum gelassen werden damit siche...

Page 31: ...6kW 907230 NARVI STONET 9kW 907232 RU 1 1 2 3 4 5 2 3 1 1 5 3 1 1 1 STONET 1 1 400 V 3N A B C D 3 3 2 A STONET 907230 6 5 8 190 3 25 100 3 60 5x1 5 3x10 STONET 907232 9 8 14 190 5 25 100 3 60 5x2 5 3...

Page 32: ...cannot be fastened to a wall recess 3 3 1 H07RN F 7 1 3 11 3 12 2 2 2 9 x 16 2 1 3 13 90 60 3 2 3 5 15 2 1 3 0 10 C min B min A min min 3 cm A min A min max 30 cm 10cm Kuva 3 2 min 20cm Max 9 0cm Kuva...

Page 33: ...00 X min mm Kuva 2 X min 160 225 225 240 4 8x25 6kpl 278 160 50 300 300 7 0 7 0 Tason kannatusruuvien paikat lattiasta 860 mm Kuva 4 1 4 2x9 5 3kp l Kuva 4 2 4 2x9 5 3kp l 4 2x9 5 3kp l Kuva 4 4 4 2x9...

Page 34: ...4 3 ON OFF 30 4 4 15 4 2 60 C 115 C 4 1 I O SET ON OFF ON OFF 6 ON OFF SET...

Page 35: ...4 5 ON OFF ON OFF 3 3 3 4 6 1 SET 30 SET SET SET 60 C 115 C SET ON OFF ON OFF I O SET 1...

Page 36: ...15 1 SET 2 3 SET 4 SET 5 1 4 7 3 d 1 d 1 d 2 d 3 d 1 d 2 d 3 SET SET 1 d E01 E02 E03 4 8 100 C 2 5 1 I O 2 SET 3 SET 4 2 30 5 SET 6 14 7 SET 3 1 I O 2 SET 3 3 00 4 SET 5 SET 6 SET SET...

Page 37: ...1 SET 2 ON OFF 3 SET 4 SET 5 SET 5 5 1 60 C 115 C 24 4 5 2 IPX4 5 3 230 3 50 16 A 10 5 IPX4 144 C 100 6 3 6 100 1000 500 100 150...

Page 38: ...9 1 2 1 2 10 400V 3N t J1 2 2 3 1 4 J1 1 J1 3 J1 4 J2 NTC VA1 VA2 VA3 NTC A1 A2 YLS ON OFF B1 B2 NTC 12V CTL __ J7 J8 L1 L1 N CTL L2 L2 PE PE L3 L3 N J10 J9 CTL J1 5 J1 6 CLK Y AL 5 6 X6 A1 A2 B1 B2...

Page 39: ......

Page 40: ...Narvi Oy Yritt j ntie 14 27230 Lappi Finland Tel 358 207 416 740 www narvi fi 10 2013...

Reviews: