Technical data

Narvi 16 NC

Narvi 20 NC

Narvi 24 NC

Narvi 20 NC VS

Height

78 cm

80 cm

82 cm

73 cm

Width

50 cm

54 cm

58 cm

59 cm

Depth

58 cm

58 cm

58 cm

57 cm

Operation weight

122 kg

136 kg

162 kg

124 cm

Stone Ø 10-15 cm

20 kg

40 kg

40 kg

20 kg

Stone Ø 5-10 cm

30 kg

20 kg

40 kg

30 kg

Steam room size

8–16 m

3

8–20 m

3

10–24 m

3

8–20 m

3

External diameter of the connective flue 119 mm

119 mm

119 mm

119 mm

Distance of the bottom edge of the 

connective flue from the floor (min.) + 

adjustment space for adjustable legs 

0-35 mm

58 cm 

58 cm 

58 cm 

54 cm

Firebox cover

10 mm

10 mm

10 mm

10 mm

Control plate of the firebox

6 mm

6 mm

6 mm

6 mm

Depth of the firebox

415 mm

415 mm

415 mm

415 mm

Height of the firebox

335 mm

335 mm

335 mm

335 mm

Volume of the water tank

23 l

AIR FLOW CONTROL PLATES FOR NARVI NC 16, NC 

20, NC 24 and NC 20 VS. 

(There is no air flow control plates for NC 20 VS)

INSTALLATION OF THE FAUCET, water 
tank models (20 NC VS)
The water tank is on the side of the 
stove and it has a large opening for 
filling it. The faucet is installed when the 
stove is installed.
Figure 9. Place the faucet so that the 
threads are visible on the inside of the 
tank. Place the washer on the outside of 
the tank, turn the locking nut into place 
with the smooth side against the washer 
and tighten, turning the faucet clockwise 
and holding the keeper in place with a 
wrench.

Figure 9

Summary of Contents for NC 16

Page 1: ...NARVI SAUNA HEATERS NC 16 NC 20 NC 24 and NC 20 VS INSTALLATION USER AND MAINTENANCE INSTRUCTIONS EN Narvi Oy Yrittäjäntie 14 FI 27230 LAPLAND FINLAND Phone 0207 416 740 www narvi fi narvi narvi fi ...

Page 2: ...oden parts 500 mm Figure 1 The protection must also be clear of the floor and the ceiling 2 The safety clearance mentioned in paragraph 1 can however be reduced by half 250 mm when light single protection is used Single light protection of this type can be made of a non combustible fibre reinforced cement board of at least 7 mm thick or of a metal plate of at least 1 mm which has been fastened sec...

Page 3: ...with a metal plate that reaches at least 100 mm to both sides of the sauna heater and 400 mm in front There must be 1000 mm free room in front of the hatch Figure 7 INSTALLATION OF THE SAUNA HEATER In all our sauna heater models there is the smoke opening in the connective flue on top and rear of the firebox Block the unused opening with the cover plate included in the delivery Also included in th...

Page 4: ...m Control plate of the firebox 6 mm 6 mm 6 mm 6 mm Depth of the firebox 415 mm 415 mm 415 mm 415 mm Height of the firebox 335 mm 335 mm 335 mm 335 mm Volume of the water tank 23 l AIR FLOW CONTROL PLATES FOR NARVI NC 16 NC 20 NC 24 and NC 20 VS There is no air flow control plates for NC 20 VS INSTALLATION OF THE FAUCET water tank models 20 NC VS The water tank is on the side of the stove and it ha...

Page 5: ...ust be emptied Start by lightning a small quantity of wood on the upper surface of the wood When the wood is burning properly add more wood to 2 3 of the height of the firebox To burn properly wood needs air Use the draught regulator to adjust the amount of air Avoid heating the sauna stove so that the channels of the stone basket glow red for a long time because this will overload the firebox and...