INSTALLATION, USER AND 

 

MAINTENANCE INSTRUCTIONS

NARVI SAUNA HEATERS NC 16, NC 20, NC 24 and NC 20 VS.

SAFETY INTERVALS
Before installing the sauna heater ensure the required safety clearances for 
structures made of inflammable material are met. The safety clearances of the 
wood-burning sauna heater are 500 mm to the sides and to the rear and 1200 
mm upwards. At the base of the sauna heater, a concrete board of at least 70 
mm or KOTA installation base must be used. If you are unsure please contact 
your local rescue board for guidance. 

NB! If the sauna heater is installed on top of floor heating, a KOTA installation 
base must be used. 

Inflammable construction parts, such as 
wooden walls, sauna seats, etc. 

1. Minimum distance from the vertical surfaces 
of the sauna heater to unprotected wooden 
parts 500 mm.  (Figure 1) 

The protection must also be clear of the floor 
and the ceiling.

2. The safety clearance mentioned in 
paragraph 1 can, however, be reduced by 
half (250 mm) when “light-single” protection 
is used. Single-light protection of this type 
can be made of a non-combustible, fibre-
reinforced cement board of at least 7 mm thick 
or of a metal plate of at least 1 mm, which has 
been fastened securely enough to the wall. A 
ventilation gap of at least 30 mm must be left 
between the wooden surface to be protected 
and the safety plate by using piping collars. 
(Figure 2)

3. The safety clearance in paragraph 2 can be 
further reduced to half (125 mm) when double 
protection is used. Double protection can be 
made of two plates as described in paragraph 
2 and, then a ventilation gap of at least 30 mm 
must be left between the wall and the plates. 
(Figure 3) 

 

30 mm ventilation gap

1 mm metal plate or 7 mm 
non-combustible, fibre-
reinforced concrete board

Figure 1

Firgure 2

Firgure 3

30 mm ventilation gap

1 mm metal plate or 7 mm 
non-combustible, fibre-
reinforced concrete board

EN

Summary of Contents for NC 16

Page 1: ...NARVI SAUNA HEATERS NC 16 NC 20 NC 24 and NC 20 VS INSTALLATION USER AND MAINTENANCE INSTRUCTIONS EN Narvi Oy Yrittäjäntie 14 FI 27230 LAPLAND FINLAND Phone 0207 416 740 www narvi fi narvi narvi fi ...

Page 2: ...oden parts 500 mm Figure 1 The protection must also be clear of the floor and the ceiling 2 The safety clearance mentioned in paragraph 1 can however be reduced by half 250 mm when light single protection is used Single light protection of this type can be made of a non combustible fibre reinforced cement board of at least 7 mm thick or of a metal plate of at least 1 mm which has been fastened sec...

Page 3: ...with a metal plate that reaches at least 100 mm to both sides of the sauna heater and 400 mm in front There must be 1000 mm free room in front of the hatch Figure 7 INSTALLATION OF THE SAUNA HEATER In all our sauna heater models there is the smoke opening in the connective flue on top and rear of the firebox Block the unused opening with the cover plate included in the delivery Also included in th...

Page 4: ...m Control plate of the firebox 6 mm 6 mm 6 mm 6 mm Depth of the firebox 415 mm 415 mm 415 mm 415 mm Height of the firebox 335 mm 335 mm 335 mm 335 mm Volume of the water tank 23 l AIR FLOW CONTROL PLATES FOR NARVI NC 16 NC 20 NC 24 and NC 20 VS There is no air flow control plates for NC 20 VS INSTALLATION OF THE FAUCET water tank models 20 NC VS The water tank is on the side of the stove and it ha...

Page 5: ...ust be emptied Start by lightning a small quantity of wood on the upper surface of the wood When the wood is burning properly add more wood to 2 3 of the height of the firebox To burn properly wood needs air Use the draught regulator to adjust the amount of air Avoid heating the sauna stove so that the channels of the stone basket glow red for a long time because this will overload the firebox and...