background image

3.2 Installation of control unit

-  The control unit can be installed either in the sauna or in the dressing room. In the  
  sauna the control unit shall be installed at a height of at most 65 cm. Cf. Fig. 5.
-  Install the stand for the control unit on the wall and the control unit on the stand. Fig. 5.
-  The wiring of the control unit can be shortened. The wire may not be inserted in    
  the connection box of the stove.
-  Surface installation of control unit into contact box. Fig. 6.2.

min. 20 cm

m

ax

 6

cm

Installation of control unit on 

the wall. NOTE! The control unit 

must not be installed in a wall 

recess.

Fig. 5.

Use little 
screwdriver 
when you open 
the cover. Push 
with screwdriver 
salients in. In the 
picture arrows 
shows where 
salients are.

Fig. 6.1

Surface installation of control unit 

in dressing room.

Fig. 8.

Surface installation of control unit in sauna.

Fig. 7. 

Control unit

Fig. 9.

Surface installation of control unit 

into contact box.

Fig. 6.2

4. CONTROL UNIT
  4.1 Instructions for use of control unit

  1. On/Off pushbutton

  •  When the display is off, pushing this button  will switch on the control unit 

    and the stove. The button shall be held down for more than 1 second.

  •  The control unit and the stove can be 

switched off by pressing the button again    

    and holding it down (for more than 1 second).

  •  When the stove is switched on, the pre-selection time will be displayed 

    (yellow LED is on).
    The pre-selection time remains on the display for 5 seconds, and then 
    the measured temperature is displayed (basic status).

Reviews: