3. INSTALLATION:

3.1 Installation of stove and sensing element

-  Fasten the fixing plate for the stove on the wall as shown in Fig. 2. Use the 2 screws  
  included in the delivery.
-  Electrical connection of the stove may only be carried out by a qualified electrician   
  in compliance with valid regulations.
-  The connection cable shall be a rubber sheathed cable of type H07RN-F or   

 

  corresponding. Cable size and fuse rating as indicated in Table 1.

-  Connection of connection cable
  -  turn the stove bottom up
  -  open the base of the electrical box
  -  plug in the connection cable
  -  There is socket for control unit and 
    element. Put sockets for connection 
    plugs. (Fig. 3.1)
  -  Install cable clamps to electrical box wall.
  -  replace the base of the electrical box
  -  turn the stove upright

-  Install the sensing element on the wall. 
  Cf. Fig. 3.2.
-  The wiring for the sensing element 
  can be embedded.

  INSTALLATION ON THE WALL:

-  Draw in the lugs on the rear side of 
  the sauna stove through the mounting slots 
  of the mounting plate on the wall (Fig. 4A).
-  Push the upper edge of the mounting plate 
  between the jacket and upper frame of 
  the sauna stove and make sure that the 
  lugs of the stove are wedged into the slots 
  of the mounting plate on the wall (Fig. 4B).
-  Tighten the upper edge of the sauna stove 
  with a locking screw (Fig. 4C).
-  The stone basket is now locked in the 
  jacket and on the mounting plate of 
  the sauna stove.  

X

min.250

min.260

121

121

121

250

TYYPPI

X min

mm

ELECTRON 450

130

ELECTRON 600

130

ELECTRON 800

180

ELECTRON 900

180

Fig 2. Fixing plate position

A

A

A

C

B

D

min. 5 cm

m

ax

 3

cm

Fig 1. Safety distances for ELECTRON stove

Installation of stove 

in a wall recess

TYPE

5 cm

Fig. 3.2

Installation of sensing 

element on the wall. 

The sensor shall be on the 

centre line of the stove.

A

B

C

Fig. 4.

Fig 3.1 Connections of circuit plate

Connecting plug 

for sensing element

Connecting plug 

for control unit