![NARVI B-2003 Manual Download Page 20](http://html1.mh-extra.com/html/narvi/b-2003/b-2003_manual_3296453020.webp)
1.3 Programming of weekly clock
When the clock has been set, you can set the weekly clock.
1. Press the SET key and hold it down until the green signal light is switched on.
You can now start the programming of the first memory location.
2. The total number of memory locations is 7 and they are shown on the display
separated by hyphens. E.g. –1–
Choose the memory location with the +/- key.
3. After you have chosen the memory location, press the SET key, and the START
hours start to flash. Set the start hours with the +/- key.
4. Press the SET key again, and the START minutes start to flash. Set the start
minutes with the +/- key.
5. Press the SET key again, and the STOP hours start to flash. Set the stop hours
with the +/- key.
6. Press the SET key again, and the STOP minutes start to flash. Set the stop minutes
with the +/- key.
7. Press the SET key again to set the starting day 1-7
(1= Monday… 7= Sunday).
If the starting day is set at 0, the memory location is not in use. For example, even
if the start and stop time have been set, but the starting day is set at 0, the stove
will not be switched on at the set time.
8. When you have set also the starting day, press the SET key once more, and you
can choose the next memory location with the +/- key.
9. If you do not wish to program any more memory locations, do nothing and the
control centre will return to the basic display.
When the weekly clock is programmed, the control centre automatically checks the
correct relationship between switching-on time and switching-off time. If the
switching-on time exceeds 12 hours or the time between switching-off time and
new switching-on time is less than 6 hours, the control centre issues error message
ERR4 and the programming will not be stored.
1.4 Signal light indications
A. Red light = on until the set temperature is reached for the first time.
B. Yellow light = flashes when the pre-selection time is displayed (time runs down).
Yellow light = on when the remaining switching-on time is displayed.
C. Green light = flashes when adjustment of the target temperature is possible.
1.5 Error messages
• ERR1= A break in the sensor circuit.
• ERR2= A short-circuit.
• ERR3= A break in the overheat protector's current circuit.
• ERR4= Error in weekly clock programming.
NOTE! When an error message is displayed, the sauna stove is switched off.
1.6 Technical data
• Temperature adjustment range 40
°
C-115
°
C
• Temperature display 20
°
C-125
°
C
• In increments of 1
°
C
• Pre-selection time max. 24h
• In increments of 1/2 h
• If pre-selection time is 1 hour or less, in increments of 1 min.
Summary of Contents for B-2003
Page 1: ......
Page 2: ......
Page 5: ...LT HU PL...
Page 6: ...RO...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 67: ......