7.22 AUTOMATIC STOP SYSTEM:
The compressor is equipped with an automatic stop system, which stops the compressor when the desired pressure is
reached. This pressure switch is calibrated by NARDI COMPRESSORI at the time of testing of the finished compressor.
This way, the operators do not need to stand next to the compressor all the time while the cylinders get filled, but may
dedicate themselves to other activities. Once the cylinders are filled, the machine stops automatically, keeping the
system in pressure, and the operator can proceed to the closing of the filling valve at any time. The full cylinder can then
be replaced with an empty one (if additional cylinders need to be filled) and restart the compressor by pressing the
START button on the electronic control panel. In case of danger or faults, press the red EMERGENCY button, which is
located on the electronic control panel and the machine stops immediately. To restart the machine after an emergency,
release the red button (knob) turning it counter-clockwise and press START.
1.
Main switch and door lock.
2.
Emergency knob and stop button.
3.
Start button ( START ).
4.
General alarms – red LED ( GENERAL ALARMS ).
5.
Compressor on – green LED (COMPRESSOR ON).
6.
White LED indicates electronic panel is on.
7.
Condensate drain button (PURGE)
8.
Liquid crystal display.
9.
Page button (PAGE)
10.
Up arrow button ( ▲).
11.
Down arrow button ( ▼).
12.
Reset button ( RESET ).
7.23 USE OF THE ELECTRONIC CONTROL PANEL:
CAUTION:
The electronic control panel is an advanced
component that allows you to monitor the compressor and at
the same time change its parameters of use.
The electronic panel is set by Nardi Compressori at the time of production based
on the pressure and with the standard parameters.
The electronic control panel is composed of the following buttons:
LINE SWITCH: This switch is used to provide power to the electronic panel and all electrical parts. When it is set to "0"
no component has voltage but, when it is necessary to operate within the compressor you should still unplug the power
from the electrical outlet. When it is switched to the position "I" is blocks the opening of the electronic panel and the
compressor and all electrical components are powered.
STOP BUTTON: Used to turn off the compressor. Once you push on it to turn off the compressor it needs to be reset to
its normal position by turning the nob clockwise.
START BUTTON: This button turns on the compressor.
PURGE BUTTON: This button is pressed during operation of the compressor and it is used to drain the condensate
which is collected in the intermediate separators and in the filter.
PAGE - ▲- ▼- RESET BUTTONS: These buttons are used to scroll the menu of the electronic panel and to modify the
operating parameters of the compressor.
LED LIGHT LINE:
When on, this white LED light indicates that there is electrical current in the electronic control
panel and its components.
LED LIGHT COMPRESSOR ON: This green LED light indicates that the compressor is running.
LED LIGHT GENERAL ALARMS: This red LED flashing light indicates a problem or an alarm.