© 2005 WOLF STEEL LTD.
ALL RIGHTS RESERVED, NO PART OF THIS BOOK MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS - GRAPHIC, ELECTRONIC OR MECHANICAL WITHOUT THE
PRIOR WRITTEN PERMISSION FROM WOLF STEEL LTD., BARRIE, ONTARIO, CANADA
ISO-176 W415-0118 / B / 10.25.06
45
Testing & Adjustments
Testing: Function - Magnet Coil - SIT 820 Nova Valve
Since the resistance of the magnet coil is too low to be read by most meters (0.015 milliohms),
a “hold-in” test is more practical. Connect one millivolt meter lead to the thermocouple capil-
lary tube. The other lead should be connected to the solder button on the bottom of the valve.
Light the pilot and hold in the on/pilot/off knob until your multimeter registers the proper amount
of millivolts to keep the pilot burning (6 millivolts for regular product, 4.2 millivolts for vent-free
product).
At this point, the knob is released and the pilot should continue to burn. If it does not continue
to burn, the valve fails the test and should be replaced.
SOLDER BUTTON
6.00
Summary of Contents for W415-0118
Page 1: ......
Page 104: ...W415 0118 10 12 06 ISO 176 ...