© 2005 WOLF STEEL LTD.
ALL RIGHTS RESERVED, NO PART OF THIS BOOK MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS - GRAPHIC, ELECTRONIC OR MECHANICAL WITHOUT THE
PRIOR WRITTEN PERMISSION FROM WOLF STEEL LTD., BARRIE, ONTARIO, CANADA
ISO-176 W415-0118 / B / 10.25.06
38
Testing & Adjustments
Testing: Pressures
Inlet
Outlet
Outlet
After taking pressure readings, be sure to turn screws clockwise fi rmly to reseal.
DO NOT OVER TORQUE!
Use an appropriate screwdriver with .150” x .030” blade.
To test inlet / outlet pressure by turning screw counter-clockwise 2 or 3 turns and then place gauge tubing over
inlet / outlet hose fi tting.
Test inlet pressure with the main burner on to determine if gas fl ow is suffi cient.
Inlet
SUPPLY
NATURAL GAS
PROPANE
MANIFOLD
7”
WATER COLUMN
11”
WATER COLUMN
3.5”
WATER COLUMN
10”
WATER COLUMN
Summary of Contents for W415-0118