background image

9

W415-0689 / 06.25.08

RAIN TABS

DOOR REMOVAL

GLASS REMOVAL

Having removed the door, lay on a smooth 

fl

 at surface, face down.  

There are 4 glass retainers that need to be bent away from the 
glass to release it from the frame.  Do not pry on the glass.

When replacing 

DO NOT SUBSTITUTE MATERIAL

, replace the 

gasket (W562-0008) and the glass (W300-0110).  Set new glass 
into the frame and gently bend tabs into the gasket to secure.  

* Ensure that the gasketed end of the glass is placed into the top of 
the door frame.

NOTE: Care must be taken when removing and disposing of any 
broken glass or damaged components. Be sure to vacuum up 
any broken glass from inside the appliance before operation.

FIGURE 9

GLASS

RETAINERS

GASKET*

GLASS

TOP

FIGURE 11

B

O

TT

OM

DO

OR RETAINER

TO

P

DO

OR

FLAN

GE

SECURING THE DOOR IN PLACE

When shipped, the door is secured with two hitch pins 
along the top edge, replacing them is optional. 
To secure the door in place use the supplied hitch pins as 
illustrated.  

90º

60º

RAIN

TAB

When shipped, the rain tabs should be at a 90º angle.  Push 
the rain tabs down until they are at an approximate 60º angle to 
assist rain in running off and out of the unit.

HITCH

PIN

The door is held in place at the bottom by a retainer tab 
that inserts into a slot in the bottom edge of the door, and 
at the top with a tab that secures in the same fashion.  The 
door is removed by lifting it off the tabs.  When replacing, 
guide the door over the upper tab 

fi

 rst, then over the lower 

tab.

FIGURE 8

FIGURE 10

Summary of Contents for Torch GSST8N and

Page 1: ...h any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier c...

Page 2: ...from hot surfaces Any safety screen or guard removed for servicing must be replaced prior to operating the enclosure It is imperative that the control compartments burners and circulating blower and...

Page 3: ...t be responsible for installation labour or any other costs or expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisi...

Page 4: ...rating shall be reduced at the rate of 4 for each additional 1 000ft This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with o...

Page 5: ...The access to the gas inlet is located in the bottom of the cabinet 3 The shut off valve flex connector assembly must always be contained within the cabinet 4 When flexing any gas line support the ga...

Page 6: ...IT WARNING The GSST8 is designed for outdoor application only The unit must be installed in the cabinet provided The cabinet is designed to be installed on finished surfaces The GSST8 can be recessed...

Page 7: ...the metre regulator assembly to a maximum vertical distance of 15 ft H 3 FEET 3 FEET Clearance to a service regulator vent outlet I 12 INCHES 9 INCHES Clearance to a non mechanical air supply inlet t...

Page 8: ...nting surface 3 Start the fasteners into each of the six remaining mounting holes Align the keyholes of the frame to the heads of the fasteners and slide the frame down onto the fasteners Ensure the f...

Page 9: ...ide the appliance before operation FIGURE 9 GLASS RETAINERS GASKET GLASS TOP FIGURE 11 B O T TOM DOOR RETAINER T O P DOOR FLANGE SECURING THE DOOR IN PLACE When shipped the door is secured with two hi...

Page 10: ...o be secured use two screws in the holes provided behind the control door Insert the door stop chain into the receiving slot in the control door Then insert the door chain into the receiving slot in t...

Page 11: ...ht TL Top left and BL bottom left 6 Secure the wires into the clips at both sides and the bottom of the frame Use the extra clips provided to retain any loose wires 7 Re attach frame onto unit 8 Open...

Page 12: ...BE TURNED OFF AT THE LP GAS SUPPLY CYLINDER WHEN THIS APPLIANCE IS NOT IN USE DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE IMPROPER...

Page 13: ...rify proper operation after servicing This appliance should be inspected before use and at least annually by a qualified service person The appliance area must be kept clear and free of combustible ma...

Page 14: ...EALANT 25 W573 0007 HIGH TEMPERATURE SEALANT 26 W175 0270 CONVERSION KIT NG TO LP 27 W175 0274 CONVERSION KIT LP TO NG Contact your dealer for questions concerning prices and availability of replaceme...

Page 15: ...re and orifice size as specified by the rating plate values White grey film forms Sulphur from fuel is being deposited on glass logs or combustion chamber surfaces Clean the glass with a gas appliance...

Page 16: ...16 W415 0689 06 25 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Reviews: