EN
W415-1212 / 05.13.13
53
4.1.4 TYPICAL THROUGH THE WALL
If possible, design the installation so that the connector does not pass through a combustible wall. If during
your installation you must pass through a combustible wall, check with your building inspector before you
begin. Also check with the chimney connector manufacturer for any specifi c requirements.
Consult with your dealer regarding special connection components available for use for wall pass-throughs.
Use only parts that have been tested and listed for use in a wall pass-through.
61.1A
FLOOR
PROTECTOR
ROOF
FLASHING
STORM
COLLAR
TERMINAL
COMBUSTIBLE
WALL
CHIMNEY
CONNECTOR
MAINTAIN 2”
(50.8mm) CLEARANCE
THROUGH EAVE
COMBUSTIBLE
CEILING
LISTED
CHIMNEY
COMBUSTIBLE
OUTSIDE WALL
TO
STOVE
2” (50.8mm)
CLEARANCE
INSULATED
“T”
WALL
SUPPORT
WALL SPACER
FOR OUTSIDE
WALL
SECTION
LISTED
CHIMNEY PIPE
THIMBLE