www.napoleongrills.com
18
EN
Troubleshooting
Problem
Possible Causes
Solution
Low heat / Low flame when
valve turned to high.
For propane - improper lighting
procedure.
For natural gas - undersized supply
line.
Ensure lighting procedure is followed carefully. The
valve must be in the off position when the tank valve is
turned on. Turn tank on slowly to
allow pressure to equalize. See lighting
instructions.
Pipe must be sized according to installation code.
Burners burn with yellow
flame, accompanied by the
smell of gas.
Possible spider web or other debris.
Thoroughly clean burner venturi. See general
maintenance instructions.
Burner will not light with the
igniter, but will light with a
match.
Dead battery / or installed incorrectly.
Loose electrode wire or switch
terminal wires.
Improper gap at electrode tip.
Replace with heavy duty battery.
Check that electrode wire is firmly pushed onto the
terminal on the back of the igniter. Check that the lead
wires from the module to the
ignition switch (if equipped) are firmly pushed onto
their respective terminals.
The gap can be adjusted by bending the tip in or out.
Until a spark is achieved.
Burner will not stay lit when
control knob is released.
Knob not being held in long enough.
Too windy.
Glass or debris in ignition area of the
burner preventing
thermocouple from being fully
engulfed in flame.
Dirty thermocouple or thermocouple
connection.
Faulty thermocouple or valve.
Thermocouple must have time to heat up – hold the
knob in for 30 seconds after the burner lights, then
release
Unit will shut down if winds are greater than 10mph
(16km/h). Either locate to different area or use when it
is less windy.
Ensure there is no glass or other debris in ignition area,
and that the small hole below the thermocouple is
unobstructed.
Clean the thermocouple and clean the connection
between the valve and thermocouple. Ensure the
connection is properly tightened.
Replace thermocouple and / or valve.
Humming regulator.
Normal occurrence on hot days.
This is not a defect. It is caused by internal
vibrations in the regulator and does not affect the
performance or safety of the gas heater.
Humming regulators will not be replaced.
Burner output on “high”
setting is too low. (Rumbling
noise and fluttering blue
flame at burner surface.)
Lack of gas.
Supply hose is pinched.
Dirty or clogged orifice.
Spider webs or other matter in venturi
tube.
Propane regulator in “low flow” state.
Check gas level in propane cylinder.
Reposition supply hose as necessary.
Clean burner orifice.
Clean out venturi tube.
Ensure lighting procedure is followed carefully. All
valves must be in the off position when the tank valve
is turned on. Turn tank on slowly to allow pressure to
equalize. See lighting instructions.
Summary of Contents for PATIOFLAME GPFS40
Page 5: ...www napoleongrills com 5 EN DIMENSIONS Specifications 25 64cm 42 107cm...
Page 21: ...www napoleongrills com 21 EN M6 x 45 GG M6 x 4 x 4 M6 x 14 x 8...
Page 22: ...www napoleongrills com 22 EN M6 x 14 x 4 M6 x 14 x 4...
Page 23: ...www napoleongrills com 23 EN M6 x 14 x 2 M6 x 45 GG M6 x 2 x 2...
Page 24: ...www napoleongrills com 24 EN M6 x 30 x 4...
Page 25: ...www napoleongrills com 25 EN M6 x 14 x 4 x 4 x 4 x 4...
Page 29: ...www napoleongrills com 29 EN PART 1 2 8 5 3 7 6 4 9 10 11 12 14 13 16 15 PARTS DIAGRAM...
Page 30: ...www napoleongrills com 30 EN...
Page 35: ...www napoleongrills com 35 FR Sp cifications DIMENSIONS 25 64cm 42 107cm...
Page 50: ...www napoleongrills com 50 FR M6 x 14 x 8 M6 x 45 GG M6 x 4 x 4...
Page 51: ...www napoleongrills com 51 FR M6 x 14 x 4 M6 x 14 x 4...
Page 52: ...www napoleongrills com 52 FR M6 x 14 x 2 M6 x 45 GG M6 x 2 x 2...
Page 53: ...www napoleongrills com 53 FR M6 x 30 x 4...
Page 54: ...www napoleongrills com 54 FR M6 x 14 x 4 x 4 x 4 x 4...
Page 58: ...www napoleongrills com 58 FR DIAGRAMME DE PI CES PART 1 2 8 5 3 7 6 4 9 10 11 12 14 13 16 15...