background image

 

9

EN

www.napoleongrills.com

N415-0293 OCT 09.17

Gas Hook-Up Instructions

LP (Propane) Gas Cylinder Mounting

Attach cylinder retaining bracket to the base of the cylinder.  Then secure to the surface to which it sits. 

Cylinder should be on a level surface.

Cylinder Retaining Bracket

1. 

Fasten the bracket to the bottom of the propane bottle using 

bolt and nut supplied. 

2. 

Tighten the lag screw into the mounting surface 

leaving approxi

mately 1/4” (6mm) of thread above the 

surface.  

3. 

Slide propane bottle into position so that the bracket slides 

under the head of the lag screw. 

4.  Tighten the lag screw onto the bracket.
5. 

For fastening to a concrete surface a concrete anchor 

will be required. (Not supplied)

   

Cylinder Connection

: Ensure the gas regulator hose 

is kink free. Remove the cap or plug from the cylinder 

fuel valve. Insert the black QCC1 regulator nipple onto 

the QCC1 fuel valve. Hand tighten clock

wise. Do not use 

tools. Leak test all joints prior to using the appliance.

 

A leak test must be performed annually and each time 

a cylinder is hooked up or if a part of the gas system is 

replaced. 

If this appliance is to be connected directly to a house 

propane gas supply line, follow the instructions for 

the natural gas hook-up.  

WARNING!

 If these instructions are not followed exactly, a fire causing death or serious injury may 

occur.

Propane Cylinder Specifications

A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a 

cylinder with a damaged valve. The LP-gas supply cylinder must be constructed and marked in accordance 

with the U.S. D.O.T. Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for 

Transportation of Dangerous Good and Commission, CAN/CSA-B339, as applicable.
This appliance has been designed for use with a 20 lb. (9.1 kg) or 30 lb (13.6 kg) size propane cylinder only 

(not supplied).

The LP-gas supply cylinder must be provided with a cylinder-connection device compatible with the 

connection for the appliance.  The propane cylinder must be provided with a shut-off valve terminating in 

a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapor 

space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder 

shall include a collar to protect the cylinder valve.  The LP-gas cylinder must be provided with a listed 

overfill protection device (OPD).  Do not store a spare LP-gas cylinder under or near this appliance. Never 

fill the cylinder beyond 80 percent full.  

Use only the pressure regulator and hose assembly provided with this appliance. Replacement pressure 

regulators and hose assemblies must be specified by the manufacturer. The regulator supplies a pressure 

of 11 inches. water column to the appliance and has a QCC1 type fitting. Cylinders to be used with this 

unit must be supplied with a QCC1 cylinder valve.  A QCC1 cylinder has a positive seating connection, 

which will not allow gas flow until a positive seal has been achieved. It is also equipped with an excess 

flow device. In order to attain full flow to the appliance, the valve must be in the off position when the 

cylinder valve is turned on.

WARNING!

 A fire will result if the gas supply hose makes contact with the underside of the 

appliance.

Summary of Contents for LINEAR PATIOFLAME GPFL48

Page 1: ...FLAME OUTDOOR GAS FIREPLACE GPFL48 WITHOUT ENCLOSURE GPFL48M WITH ENCLOSURE 0427GF002S WARNING For Outdoor Use Only WARNING Do not try to light this appliance without reading the LIGHTING instructions...

Page 2: ...een thoroughly inspected by a qualified technician before packaging and shipping to ensure that you the customer receive the quality product you expect from NAPOLEON NAPOLEON warrants that components...

Page 3: ...be used for cooking This unit is not for use with solid fuel Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and...

Page 4: ...1830mm Always keep the appliance area clear and free from combustible materials gasoline and other flammable vapours and liquids Do not locate appliance where it can get excessively wet Do not use thi...

Page 5: ...PRESSURES NATURAL PROPANE Inlet Pressure 7 0 w c 11 0 w c MINIMUM CLEARANCE TO COMBUSTIBLES INCHES MM Side Walls 24 610 Top of unit to ceiling 72 1830 Specifications 72 1829mm CENTRE OF PATIOFLAME 24...

Page 6: ...losure The burner unit can be placed directly on combustible surfaces but the required clearances to the sides and top must still be maintained Installation Options Ensure bushing snaps into side pane...

Page 7: ...it can be built into a non combustible enclosure The control module can be removed from the burner unit and located up to 12 away from the burner unit A cap is provided to close the opening in the sid...

Page 8: ...ly hot They must be non combustible and must be able to expand and contract without cracking Raise the burner unit above the enclosure by 3 4 to reduce the temperature of the enclosure surface Tiled c...

Page 9: ...ed and marked in accordance with the U S D O T Specifications for LP Gas Cylinders or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Good and Commission CAN CSA B339 as a...

Page 10: ...mpletely open OR For an enclosure having four sides a top and a bottom a At least two ventilation openings shall be provided in the sidewalls of the enclosure located within 5 in 127 mm of the top of...

Page 11: ...sturbed when installing the cylinder s in the enclosure can be leak tested inside the enclosure The enclosure for the LP gas cylinder shall isolate the cylinder from the burner compartment to provide...

Page 12: ...tions supplied with the kit WARNING To avoid the possibility of burns conversions should only be done when the patio flame is cool Ensure burner is turned off Turn gas off at source and disconnect the...

Page 13: ...lied connect the flared end of the hose to the connector on the end of the flex tube as illustrated Tighten using two wrenches Do not use thread sealer pipe dope Leak test all joints prior to using th...

Page 14: ...bers may have a fine oil residue that needs to be cleaned prior to installation Clean the glass with mild dish soap drain rinse thoroughly and dry before installing 1 Carefully pour the glass embers o...

Page 15: ...nd remove all sources of ignition See Leak Testing Diagram for areas to check Turn all burner controls to the off position Turn gas supply valve on Brush a half and half solution of liquid soap and wa...

Page 16: ...es out repeat the procedure 4 Adjust the flame to the desired height with the burner control knob 5 If the burner will not light with the electronic igniter hold a lit long match or lit long butane li...

Page 17: ...by a qualified service person More frequent cleaning may be required as necessary It is imperative that the control compartment burners and circulating air passageways of the appliance be kept clean W...

Page 18: ...and chrome surfaces every 3 4 weeks or as often as required with fresh water and or stainless steel cleaner Control Panel The control panel text is printed directly on the stainless steel and with pr...

Page 19: ...ottom of the burner Slide the burner back and up wards to remove Cleaning Use a flexible venturi tube brush to clean the inside of the burner Shake any loose debris from the burner through the gas inl...

Page 20: ...in ignition area of the burner preventing thermocouple from being fully engulfed in flame Dirty thermocouple or thermocouple connection Faulty thermocouple or valve Thermocouple must have time to hea...

Page 21: ...ption of the problem broken is not sufficient 4 Proof of purchase photocopy of the invoice In some cases the Customer Solutions Representative could request to have the parts returned to the factory f...

Page 22: ...tray burner assembly x 19 N080 0274 bracket electrode thermocouple x 20 N585 0077 wind shield x 21 N570 0022 8 32x3 8 screw x 22 N680 0001 thermocouple x 23 N240 0028 electrode c w lead x 24 N570 000...

Page 23: ...93 OCT 09 17 Item Part Description mkgc glass embers clear 6lb ac mkgk glass embers black 6lb ac mkgb glass embers blue 6lb ac mkgr glass embers red 6lb ac Parts List x standard p propane units only n...

Page 24: ...24 EN www napoleongrills com N415 0293 OCT 09 17 1 2 3 5 6 15 8 9 10 11 12 13 14 7 16 17 18 19 20 21 21 22 23 25 26 27 28 29 30 31 32 33 34 35 36 30 2 3 3 24 Parts Diagram...

Reviews: