Natural Gas Hook-Up
This natural gas grill is supplied with a 10ft supply hose (complete with a quick disconnect) designed
for natural gas and certified for outdoor use. The gas grill is designed to operate at an inlet pressure
of 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied. The
installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to
the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be sufficiently
sized to supply the BTU/h specified on the rating plate, based on the length of the piping run. The quick
disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve
must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of
the hose must be connected to the fitting on the end of the flex tube as illustrated in the Natural Gas
Hose Attachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) These
connections must be made by a licensed gas installer. Leak test all joints prior to using the gas grill.
WARNING!
The installation must be performed by a licensed gas fitter, and all connections must
be leak tested before operating the grill.
•
Do not route hose underneath drip pan.
• Do not route hose between space in bottom shelf and back panel.
• Do not route hose over top of back panel.
• Ensure all hose connections are tightened using two wrenches. Do not use teflon tape or pipe dope
on any hose connection.
•
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a
fire.
• Do not use enclosure to store excess hose, as there is a greater chance of the hose contacting a hot
surface, it may melt and leak causing a fire.
• Leak test all the connections using a soap and water solution, as per the leak testing instructions
found in the this manual.
Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing:
This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
gas installer.
If the leak cannot be stopped,
immediately shut off the gas supply,
disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
STOP
Summary of Contents for ld410
Page 27: ...27 www napoleongrills com x6 N570 0029 1 4 20 X3 8 x1 N430 0002...
Page 28: ...28 www napoleongrills com x9 N570 0042 10 24 x 3 8...
Page 29: ...29 www napoleongrills com x4 N570 0042 10 24 x 3 8 x4 N570 0042 10 24 x 3 8 x1 N430 0002...
Page 30: ...30 www napoleongrills com x1 N570 0042 10 24 x 3 8 1 2 3 x4...
Page 36: ...36 www napoleongrills com x2 N570 0029 1 4 20 X3 8...
Page 37: ...37 www napoleongrills com...
Page 38: ...38 www napoleongrills com 1 2...