W415-1329 / 06.25.14
32
EN
For ease of accessibility, an optional remote wall switch may be installed in a convenient location. Route 2
strand solid core millivolt wire from the gas appliance to the wall switch. The recommended maximum lead
length depends on the wire size:
WIRE SIZE
MAX. LENGTH
14 gauge (1.8mm)
100 feet (30m)
16 gauge (1.5mm)
60 feet (18m)
18 gauge (1.2mm)
40 feet (12m)
DIRECT VENT MODEL GDS60-1:
Disconnect one of the wire leads to the on/off switch then connect the wire
leads from the optional wall switch / remote. See "WIRING DIAGRAM" section.
B-VENT MODEL GS60-1:
Disconnect one of the wire leads to the on/off switch then connect the wire leads
from the optional wall switch / remote / spill switch to "B" vent adaptor. See "WIRING DIAGRAM" section.
30.1
Installation and servicing to be done by a quali
fi
ed installer.
Do not use open fl ame.
•
Move the appliance into position and secure.
•
If equipped with a
fl
ex connector the appliance is designed to accept a 1/2” (13mm) gas supply.
Without the connector it is designed to accept a 3/8” (9.5mm) gas supply. The appliance is equipped
with a manual shut off valve to turn off the gas supply to the appliance.
•
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the
current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI
Z223.1 / NFPA 54 in the United States.
• When
fl
exing any gas line, support the gas valve so that the lines are not bent or kinked.
•
Check for gas leaks by brushing on a soap and water solution.
!
WARNING
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS
SPARKS OR OPEN FLAMES.
SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT
WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE
PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT
THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND
ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG.
VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.
5.5 MOBILE HOME INSTALLATION - MODEL GDS60-1
In Canada, mobile home installation may be vented horizontally or vertically. In the United States, it may only
be installed vertically. See "VERTICAL VENTING" or "HORIZONTAL AIR TERMINAL INSTALLATION" section
for installation.
For mobile home installations, the appliance must be fastened in place. It is recommended that the appliance
be secured in all installations. Use the levelling / securing kit, GDSLL-KT for this purpose.
5.6 GAS
INSTALLATION
5.7 OPTIONAL WALL SWITCH