W415-1329 / 06.25.14
31
EN
7.6A
This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum
fl
ex vent system running the
full length of a masonry chimney.
The
fl
ex liners accommodate any contours of a
masonry chimney, however, it is necessary to keep
the
fl
exible liners as straight as possible. The inlet air
collar of the termination cap must be connected to
the air intake
fl
ex liner and the exhaust collar must be
connected to the exhaust
fl
exible liner.
Both Simpson Duravent and Selkirk co-linear to
co-axial adaptors have been approved on this
appliance (
NOTE:
A vent adaptor will be required
directly off the appliance
).
Follow vent manufacturer’s installation instructions.
Different manufacturer’s venting components must
not be combined. Once the preferred manufacturer’s
appliance adaptor has been attached, the
remainder of the system must be that of the
same manufacturer.
The only exception to this rule is to use Wolf
Steel’s approved 3” (76.2mm)
fl
ex liner and
co-linear termination.
!
WARNING
RISK OF FIRE!
CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON-
COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD
RESULT IN A FIRE.
AIR
INTAKE
EXHAUST
FLUE
FLEX
LINER
*
40 FT (12.2m)
MAX.
10 FT (3.1m)
MIN
COAXIAL TO
CO-LINEAR
ADAPATER
APPLIANCE
VENT ADAPTOR
TERMINATION
* Measured from appliance
fl
ue collar to
termination
fl
ue collar