4.0 INSTALLATION
!
WARNING
FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS
EXACTLY.
ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED
RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC
W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR
WHICH MUST BE SEALED USING MILL PAC.
IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, 3 SCREWS MUST ALSO BE USED TO
ENSURE THE CONNECTION CANNOT SLIP OFF.
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTING
SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECT
VENT SECTIONS PER INSTALLATION INSTRUCTIONS.
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO
MAINTAIN CLEARANCES TO COMBUSTIBLES.
68.2A
4.1 MINIMUM CLEARANCE TO COMBUSTIBLES
As long as clearance to combustibles is kept within required distances, the most desirable and bene
fi
cial location for an
appliance is in the centre of a building, thereby allowing the most ef
fi
cient use of the heat created. The location of windows,
doors and the traf
fi
c
fl
ow in the room where the appliance is to be located should be considered. If possible, you should
choose a location where the vent will pass through the house without cutting a
fl
oor or roof joist.
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
A.
7"
B.
2"
C.
1"*
D.
17 1/2"
E.
6 1/4"
F.
9 1/2"
Minimum 20" from appliance top to ceiling
* At a distance of 1" from the wall, access to the blower switch, on-off switch or the blower power cord may not
be practical.
E
B
A
D
B
A
A
45°
C
F
SIDE W
A
LL
BACK WALL
SIDE W
A
LL
BACK WALL
ALCOVE