9
WS-415-091 / 06.26.00
HORIZONTAL VENT RUN
in feet
COMBINED
VERTICAL
RISE
in feet
VENTING OPTION #5
Use this chart to calculate the total vertical rise required
when the horizontal run is between 18 feet maximum or
3 feet maximum length when the initial vertical rise is at its
minimum of 1 foot.
FIGURES 9.
MOBILE HOME INSTALLATION
In Canada, mobile home installation may be vented hori-
zontally or vertically. In the United States, it may only be
installed vertically. See "
Vertical Venting
" or "
Horizontal
Air Terminal Installation
" for installation.
The fireplace is equipped with four 1/4" diameter holes
located near each corner of the base. For mobile home
installations, the fireplace must be fastened in place. Use
#10 screws, inserted through the holes in the base to se-
cure. It is recommended that the fireplace be secured in all
installations.
FIGURES 9
34 FT MAX
(1 FT MAX)
6 FT MAX
1 FT MIN
18 FT MAX
(3 FT MAX)