W415-0663 / C / 03.17.11

7.1A

THIS APPLIANCE USES A 4” EXHAUST / 7” AIR INTAKE VENT PIPE SYSTEM.

Refer to the section applicable to your installation. 

For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from the 
minimum vertical vent length can create dif

fi

 culty in burner start-up and/or carboning. Under extreme vent 

con

fi

 gurations, allow several minutes (5-15) for the 

fl

 ame to stabilize after ignition. Provide a means for 

visually checking the vent connection to the appliance after the appliance is installed. Use a 

fi

 restop, vent pipe 

shield or attic insulation shield when penetrating interior walls, 

fl

 oor or ceiling.

NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions 
provided for the initial installation.

!

WARNING

RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.

IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET 

FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT 

NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM 

COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENT 

NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES 

FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT 

PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS 

REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF 

EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED. 

2.4  RATING PLATE INFORMATION

*

MANIFOLD PRESSURE: 

3.5" WATER  COLUMN

PRESSION AU COLLECTEUR: 

3.5" D'UNE COLONNE D'EAU

MINIMUM SUPPLY PRESSURE: 

4.5" WATER  COLUMN

PRESSION D'ALIMENTATION  MINIMALE: 

4.5" D'UNE COLONNE D'EAU

MAXIMUM SUPPLY PRESSURE:

 7.0" WATER COLUMN

PRESSION D'ALIMENTATION MAXIMALE: 

7.0" D'UNE COLONNE D'EAU

NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.

WARNING:

THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE

ONLY WITH A  FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO  NOTADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT  WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS

0

RECESSED DEPTH / PROFONDEUR D'ENCASTRE

13"

FLOOR / PLANCHER

0

MANTLE / MANTEAU
VENT TOP / EVENT SUPERIEUR

2”

SIDES / COTES

0

VENT BOTTOM / EVENT INFERIEUR 

  

 

  1”

VENT SIDES / COTES DE L’EVENT 

  

 

  1”

2"

BACK / ARRIERE

0

TOP, SIDES & BACK: PER STAND OFF SPACERSFOR FRAMING MATERIALS. FOR FINISHING
MATERIALS SEE OWNERS MANUAL  / DESSUS, COTES &  ARRIERE: SELON LES ESPACEURS  DE
DEGAGEMENT  POUR LES MATERIAUX D'OSSATURE SELON LE MANUEL  DE PROPRIETAIRE
POUR LES MATERIAUX DE FINITION.

MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE:  2". SEE
INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER  AU MANUEL
D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.

DIRECT VENT VENTED GAS FIREPLACE HEATER . APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE
HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA
OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA  501A.
APPAREIL DE CHAUFFAGE AU GAZ VENTILÉ A L'EVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME
CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES  AU GAZ, EN VIGUEUR  AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE,
SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFAC-
TURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.

*

MANIFOLD PRESSURE: 

10" WATER  COLUMN

PRESSION AU COLLECTEUR: 

10" D'UNE COLONNE D'EAU

MINIMUM SUPPLY PRESSURE: 

11" WATER  COLUMN

PRESSION D'ALIMENTATION  MINIMALE: 

11" D'UNE COLONNE D'EAU

MAXIMUM SUPPLY PRESSURE:

 13" WATER COLUMN

PRESSION D'ALIMENTATION MAXIMALE: 

13" D'UNE COLONNE D'EAU

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER  AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.

AVERTISSEMENT:

CE FOYER UTILISE ET REQUIER T UN  THERMOCOUPLE À ACTION RAPIDE. REMPLACEZ

UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL  LTÉE.
 N'AJOUTEZ PAS A  CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE
QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEELVENT KITS. SEE OWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSAR Y AFTER SER VICING
THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A WOLF STEEL. REFERER
AU MANUEL  D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPOR TANT DE BIEN
REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH  AIR FILTERS.
CET APPAREIL DE CHAUFF AGE AU GAZ NE DOIT PAS ÊTRE UTILISÉ CONJOINTEMENT AVEC DES FILTRES À AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-1KT

W385-0393 /  D

SERIAL NUMBER/NO. DE SERIE:

GD34-1

ALTITUDE / ELEVATION

INPUT / ALIMENTATION

REDUCED INPUT / ALIMENTATION REDUITE

NATURAL  GAS MODEL

0-4500FT (0-610m)

22,000 BTU/h
13,500 BTU/h

GD34-1NT           GD34-1NTE        

CDV34-1NT         CDV34-1NTE

PROPANE MODEL

0-4500FT (0-610m)

22,000 BTU/h
13,500 BTU/h

VENTED GAS FIREPLACE/

FOYER AU GAZ AVEC EVACUATION

$16,=E‡&6$E

GD34-1PT            GD34-1PTE        

CDV34-1PT          CDV34-1PTE

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y4 CANADA

XXXXXX

For rating plate location, see “INSTALLATION OVERVIEW” section.

This illustration is for reference only.  Refer to the rating plate on the appliance for accurate information.

SAMPLE

E

SAMPLE

TH GLASS

TH GLASS

RMOCOUPLE. REPLACE

OUPLE. REPLACE

EL LTD.

CONT

CON

ACT

T

WITH

T

THE FLAMES,

HE FLAMES,

E

E

APPLIANCE.

APPLIANCE

NDEUR D'ENCASTRE

D'ENCASTRE

13"

1

ERIEUR

NT INFERIEUR 

 

T INFERIE

ES DE L’EVENT 

 

ES DE L’EVEN

2

ERS

ERS

FOR FRAMING MA

FOR FRAMING

TERIALS. FOR

ERIALS. 

A

SUS, COTES & 

US, COTES & 

ARRIERE: SELON LES E

ARRIERE: SELON LES E

 D'OSSA

OSSA

TURE SELON LE MANUEL

TURE SELON LE MANUEL

A

A

A

 D

 D

ENSION / L'EXTENSION HORIZON

NSION / L'EXTENSION HORIZ

GREA

GREA

TER EXTENSIONS.

TER EXTENSIONS

A

A

A

NSIONS PLUS GRAND

S PLUS GRAND

HROOM

ROOM

AND BED-SI

AND BED-

ARD

ARD

CAN/CSA

CAN/CSA

 Z240MH

 Z240MH

A

A

 SE

AFETY

AFETY

 ST

 ST

Y

Y

ANDARD,

ANDARD,

T

T

T

TITLE 24 CFR

TITLE 24 CFR

FACTURED HOME INST

TURED HOME INST

ALLA

A

T

T

TIONS, S

TIONS, S

A

OMOLOGUE POUR INST

UE POUR INST

ALLA

A

T

T

TION DANS 

ION DANS

A

AISON MOBILE SI SON INST

E SI SON INST

ALLA

ALLA

T

T

T

TION 

TION 

A

A

A

Z, EN VIGUEUR  AU CANADA

CANADA

 OU

 OU 

A

A

AUX E

AUX E

 SECTION 3280. DANS LE CAS OU CETT

SECTION 3280. DANS LE CAS OU CETT

DE SECURITE CONTRE L'INCENDIE POU

DE SECURITE CONTRE L'INCENDIE PO

.

MANIFOLD PRESSURE: 

MANIFOLD PRESSUR

10" WA

W T

A

PRESSION AU COLLECTEUR:

PRESSION AU COLLEC

MINIMUM SUPPL

MINIMUM SUPPL

Y

Y

L

L

L

 PRESSU

 PRESS

Y

Y

PRESSION D'ALIMENT

PRESSION D'ALIMENT

A

A

T

T

T

TI

T

A

A

A

MAXIMUM SUPPL

MAXIMUM SU

Y

Y

L  PR

 PR

Y

Y

PRESSION D'ALIME

PRESSION D'AL

UN COMB

UN COMB

APP

APP

ARE

ARE

P

P

P

SEULE

SEUL

AVERT

VER

A

A

UNI

N

AL

AL

TITUDE / ELEV

E / ELEV

L

A

A

V

V

INPUT

IN

 /

T ALIMEN

MEN

REDUCED INPUT

REDUCED

 / 

T ALIM

 4Y4 CANA

4Y4 CAN

3.0 VENTING

Summary of Contents for GD34-1NT

Page 1: ...e department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installed as an OEM installation in manufactured home USA only or...

Page 2: ...ON 22 4 3 USING RIGID VENT COMPONENTS 22 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION 22 4 3 2 EXTENDED HORIZONTAL AND CORNER TERMINAL INSTALLATION 23 4 3 3 VERTICAL AIR TERMINAL INSTALLATION 23 4 4 GAS...

Page 3: ...OSURE CLEARANCES for drywall or other combustible material See the section MINIMUM MANTEL CLEARANCES See the section FRAMING Side Wall See the section FRAMING See the section VENTING and INSTALLATION...

Page 4: ...tive that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before...

Page 5: ...1 DIMENSIONS 2 1 2 GD34 1 DIMENSIONS 2 5 8 5 3 4 GAS INLET ELECTRICAL INLET LEFT SIDE 33 29 5 8 6 3 4 17 34 1 4 17 1 8 13 15 11 29 4 DIA 7 DIA 2 5 8 5 3 4 GAS INLET ELECTRICAL INLET LEFT SIDE 33 29 5...

Page 6: ...u should choose a location where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material...

Page 7: ...ply Pressure 4 5 Water Column 11 Water Column 4 5 Water Column 11 Water Column Max Inlet Gas Supply Pressure 7 Water Column 13 Water Column 7 Water Column 13 Water Column Manifold Pressure Under Flow...

Page 8: ...VIGUEUR AU CANADA OU AUX ETATS UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES TITRE 24 CFR SECTION 3280 DANS LE CAS OU CETTE NORME D ETATS UNIS NE PEUT ETRE APPLIQUEE SE REFE...

Page 9: ...rmination kits wall terminal kit GD222 GD222R or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 flat roof terminal kit GD112 or periscope kit GD201 for wall penetrati...

Page 10: ...11 3 2 TYPICAL VENT INSTALLATION 16 MINIMUM 40 FT MAXIMUM 3 FT MINIMUM 29 5 8 See VENTING section GD34 1 24 MINIMUM 24 MAXIMUM 29 5 8 53 5 8 MINIMUM PLUS RISE BGD34 1 10 MINIMUM 24 MAXIMUM 29 5 8 39 5...

Page 11: ...ove grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum 12 above grade The maximum allowable vent length is 10 9 1 3 3 SPECIAL VENT I...

Page 12: ...jacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The terminal shall...

Page 13: ...aximum of 40 feet 4 2 times the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 14 1 For the following s...

Page 14: ...HT VT 9 9 11 20 9 FT Formula 1 HT VT 9 9 11 Formula 2 HT VT 40 FT 20 9 40 Since both formulas are met this vent configuration is acceptable See graph to determine the required vertical rise VT for the...

Page 15: ...4 2 VT Formula 2 HT VT 24 75 feet Example V1 VT 6 FT H1 3 FT H2 5 FT HR H1 H2 3 5 8 FT HO 03 two 90 elbows 90 03 180 90 2 7 FT HT HR HO 8 2 7 10 7 FT HT VT 10 7 6 16 7 FT Formula 1 HT 4 2 VT 4 2 VT 4...

Page 16: ...following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example V1 5 FT V2 6 FT V3 10 FT VT V1 V2 V3 5 6 10 21 FT H1 8 FT H2 2 5 FT HR H1 H2 8 2 5 10 5 FT HO 03 four 90 elbows 90 03 360 90 8...

Page 17: ...2 1 1 5 4 5 FT H1 6 FT H2 2 FT HR H1 H2 6 2 8 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 8 8 1 16 1 FT HT VT 16 1 4 5 20 6 FT Formula 1 HT 3VT 3VT 3 x 4 5 13 5 FT 16 1 13 5 Since this formu...

Page 18: ...ER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573 0002 NOT SUPPLIED OR BLACK HIGH TEMP MILL PAC W573 0007 NOT SUPPLIED WITH THE EXCEPTION...

Page 19: ...from your authorized dealer distributor See accessories to order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof...

Page 20: ...length taking into account the additional length needed for the finished wall surface Slip the vent pipe a minimum of 2 over the inner sleeve of the air terminal and secure with 3 8 screws Apply a he...

Page 21: ...tor leaving a min 3 4 of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector...

Page 22: ...using Mill Pac 25 1 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION A Move the appliance into position Measure the vent length required between terminal and appliance taking into account the additional len...

Page 23: ...penetrate the roof when fastened If the attic space is tight we recommend threading the Wolf Steel vent pipe collar or equivalent loosely onto the air terminal connector vent pipe assembly as it is p...

Page 24: ...TROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE...

Page 25: ...l installations Always turn off the pilot and the fuel supply at the source prior to moving the mobile home After moving the mobile home and prior to lighting the appliance ensure that the logs are po...

Page 26: ...the thickness of the finished floor materials i e tile carpeting hard wood which if not planned for will interfere with the opening of the lower access door and the installation of many decorative fla...

Page 27: ...AS CEMENT BOARD CERAMIC TILE MARBLE ETC DO NOT USE WOOD OR DRYWALL ANY FIRE RATED DRYWALL IS NOT ACCEPTABLE WARNING FINISHING MATERIAL MINIMUM ENCLOSURE HEIGHT STEEL HEADER INSTALLATION 1 2 34 3 4 3...

Page 28: ...COULD RESULT THE APPLIANCE REQUIRES A MINIMUM ENCLOSURE HEIGHT MEASURE FROM THE APPLIANCE BASE IF STEEL STUD FRAMING KITS WITH CEMENT BOARD ARE PROVIDED THEY MUST BE INSTALLED 71 1 It is best to fram...

Page 29: ...than 6 is required This can be considered a side wall with no length boundary 34 3 4 33 1 4 13 1 4 FINISHING MATERIAL 5 3 4 GAS INLET LOCATION 2 5 8 49 3 8 ENCLOSURE TOP 14 1 2 MINIMUM HEADER 3 1 2 M...

Page 30: ...UNOBSTRUCTED WARNING See VENTING section 5 3 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES GD34 1 6 1 33 3 4 63 3 8 2 STEEL HEADER 53 5 8 MINIMUM PLUS RISE 2 1 BRICK COMBUSTIBLE NON COMBUSTIBLE 0 IF NO...

Page 31: ...THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 Mantel clearance can vary according to the mantel depth Use the graph to help evaluate the clearance needed Combu...

Page 32: ...DOOR REMOVAL AND INSTALLATION WARNING GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED DO NOT OPERATE THE APPLIANCE WITH LATCH...

Page 33: ...lose to the rear wall of the firebox as possible A B Sit the bottom of log 2 onto the locating pin on the left side of the log support Position the top of the log into the pocket provided on the top o...

Page 34: ...log 3 against the centre grate post Rest the top of log 3 into the pocket at the top end of log 2 Place the bottom of log 4 onto the locating pin on the right side of the log support Rest the top int...

Page 35: ...the louvre assembly back Lift the clip HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre open ing Secure using a screw through the centre slot 6 5 CHARCOAL EM...

Page 36: ...nge screen and valve control door lower louvres from the base of the appliance Tilt the blower onto its side Slide it past the controls and into the clip C Secure to the threaded stud using the lock w...

Page 37: ...that any excess wire is contained preventing it from making contact with moving or hot objects Because the blower is thermally activated when turned on it will automatically start approximately 10 min...

Page 38: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Page 39: ...9 1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized flame Turn in a clockwise direction to reduce the gas flow Inlet pressure can be checked by turning screw A counter clockwi...

Page 40: ...te and rotate the plate 180 Secure using the same two screws through the existing holes Vertical terminations running longer than 15 feet may display a very active flame If this appearance is not desi...

Page 41: ...nd bottom of the door is not broken or missing Replace if necessary 8 If for any reason the vent air intake system is disassembled re install and re seal per the instructions provided for the initial...

Page 42: ...the gasket holding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CAR...

Page 43: ...W665 0011 W665 0011 NAILING TAB TRIM SIDE 22 W665 0014 W665 0014 NAILING TAB TOP 23 W010 1777 W010 1777 FIRESTOP ASSEMBLY 24 W456 0050 50 W456 0044 44 NATURAL GAS ORIFICE 24 W456 0057 57 W456 0055 55...

Page 44: ...W490 0073 4 7 INNER OUTER SLEEVE 40 W010 0567 ROOF SUPPORT 41 W263 0054 ROOF FLASHING 42 W170 0063 STORM COLLAR GD 111 8 12 TO 12 12 PITCH 38 W670 0006 AIR TERMINAL 39 W490 0073 4 7 INNER OUTER SLEEVE...

Page 45: ...ELS 64 PRP33 PORCELAIN REFLECTIVE PANELS 65 GD33B KT BAY FRONT C W PULL SCREEN 66 GIB 1LK BAY LOUVRE KIT PAINTED BLACK 66 GIB 1LAB BAY LOUVRE KIT ANTIQUE BRASS 66 GIB 1LSS BAY LOUVRE KIT STAINLESS STE...

Page 46: ...46 W415 0663 C 03 17 11 42 41 40 38 14 47 4 3 2 5 8 10 11 12 13 52 57 39 40 46 36 37 45 30 23 26 25 29 16 1 15 24 68 67 66 65 56 73...

Page 47: ...burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals if main burner lights replace swi...

Page 48: ...ames are very aggressive Door is ajar Ensure the mechanical means of securing the door is providing a tight seal Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has...

Page 49: ...r plated trim or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under t...

Page 50: ...50 W415 0663 C 03 17 11 43 1 14 0 SERVICE HISTORY...

Page 51: ...51 W415 0663 C 03 17 11 15 0 NOTES 44 1...

Page 52: ...52 W415 0663 C 03 17 11 44 1...

Reviews: