background image

1

W415-1002 / B / 04.14.16

INSTALLER:  LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:  RETAIN THIS MANUAL FOR FUTURE REFERENCE.

NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.

INSTALLATION AND 

OPERATING INSTRUCTIONS

1.22D

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 

103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone (705)721-1212 • Fax (705)722-9081 • www.napoleonfi replaces.com • [email protected]

SAFETY INFORMATION

!

WARNING

If the information in these instructions are 
not followed exactly, a fi re or explosion 
may result causing property damage, 
personal injury or loss of life.

- Do not store or use gasoline or other fl ammable 
vapors and liquids in the vicinity of this or any 
other appliance.

- WHAT TO DO IF YOU SMELL GAS:
• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use        
any phone in your building.

• 

Immediately call your gas supplier from a        
neighbour’s phone.  Follow the gas supplier’s        
instructions.

• 

If you cannot reach your gas supplier, call the        
fi re department.

- Installation and service must be performed by a 
qualifi ed installer, service agency or the supplier.

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

$10.00

HOT GLASS WILL CAUSE 

BURNS.

DO NOT TOUCH GLASS UNTIL 

COOLED.

NEVER ALLOW CHILDREN TO 

TOUCH GLASS.

!

DANGER

A barrier designed to reduce the risk of burns from 
the hot viewing glass is provided with this appliance 
and shall be installed for the protection of children 
and other at-risk individuals.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is only for use with the type of gas  
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless 
a certifi ed kit is used.

Decorative Product: Not for use as a heating appliance.

BARRIER

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES.

GD19

LOG & BURNER ASSEMBLY

B19NL

NATURAL GAS

B19PL

Summary of Contents for GD19

Page 1: ...bour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be performed by a quali ed installer service agency or th...

Page 2: ...3 2 3 CHARCOAL EMBERS 3 2 4 VERMICULITE 3 2 5 GLOWING EMBERS 4 3 0 ADJUSTMENT 4 3 1 FLAME CHARACTERISTICS 4 3 2 VENTURI ADJUSTMENT 4 4 0 REPLACEMENTS 5 BURNER ASSEMBLY SCREW LOCATIONS ORIFICE LOCATIO...

Page 3: ...removed see GD19 INSTALLATION INSTRUCTIONS C Place the center log as shown ensuring the holes on the underside are placed onto the two centre pins D Place the hole in the underside of the right log o...

Page 4: ...rs into pieces and place along the burner ports covering all of the burner Care should be taken to shred the embers into thin small irregular pieces as only the exposed edges of the bre hairs will glo...

Page 5: ...cies on replacement parts Normally all parts can be ordered through your Authorized dealer distributor FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE...

Page 6: ...6 W415 1002 B 04 14 16 44 1 5 0 NOTES...

Page 7: ...7 W415 1002 B 04 14 16 44 1...

Page 8: ...8BUFSGBMMT t 8PPE 4UPWFT FBUJOH PPMJOH t MFDUSJD JSFQMBDFT t 0VUEPPS JSFQMBDFT t BT SJMMT JSFQMBDFT FBUJOH PPMJOH DBMM t SJMMT DBMM napoleonproducts com BQPMFPO 3PBE BSSJF 0OUBSJP BOBEB BZWJFX SJWF B...

Page 9: ...e cet ap pareil ou tout autre appareil QUE FAIRE SI VOUS D TECTEZ UNE ODEUR DE GAZ N allumez aucun appareil Ne touchez aucun interrupteur lectrique n utilisez aucun t l phone dans votre immeuble Appel...

Page 10: ...ustible voulu puis installez l ensemble de conversion s il y a lieu Voir la section R GLAGE DU VENTURI A Remettez en place le br leur en vous assurant que le venturi est bien plac par dessus l injecte...

Page 11: ...VEMENT DE LA PORTE VITR E C Placez la b che centrale tel qu illustr en vous assurant que les trous sous la b che soient plac s sur les deux tiges centrales D Positionnez le trou sous la b che droite...

Page 12: ...ISES INCANDESCENTES Ouverture du volet d air PL 1 16 GN 1 32 L ouverture du volet d air a t pr r gl e en usine selon le tableau ci dessous Ind pendamment de l orientation du venturi plus le volet est...

Page 13: ...ce Fini POUR PLUS D INFORMATION CONTACTEZ VOTRE D TAILLANT AUTORIS AVERTISSEMENT OMETTRE DE POSITIONNER LES PI CES CONFORM MENT AUX INSTRUCTIONS DU MANUAL OU D UTILISER UNIQUEMENT DES PI CES SP CIFIQ...

Page 14: ...44 1 5 0 NOTES 6 W415 1002 C 04 14 16...

Page 15: ...44 1 7 W415 1002 C 04 14 16...

Page 16: ...CPJT t 1SPEVJUT 7 t PZFST MFDUSJRVFT t PZFST FYU SJFVST t SJMT HB EF RVBMJU PZFST IBVGGBHF FU MJNBUJTBUJPO SJMT DPNQPTF napoleonproducts com 3PVUF 5SBOTDBOBEJFOOF POUS BM 2V CFD 5 BQPMFPO 3PBE BSSJF 0...