electrical information
6.0 electrical information
1
2
!
WARNING
• Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor gas appliance.
• Ensure that all power sources have been shut off prior to beginning any electrical work.
• Do not use this appliance if any part has been under water. Call a qualified service technician immediately to
have the appliance inspected for damage to the electrical circuit.
• Risk of electrical shock or explosion. Do not wire 110v to the valve or to the appliance wall switch. Incorrect
wiring will damage controls and is not covered by the warranty.
• All wiring should be done by a qualified electrician and shall be in compliance with local codes. In the absence
of local codes, use the current CSA22.1 Canadian Electrical Code in Canada or the current National Electrical
Code ANSI/NFPA No. 70 in the United States.
A qualified electrician must remove the cord connection and wire the appliance directly to the household wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hardwired. In the
absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the current ANSI/NFPA
No. 70 in the United States.
1. Remove the junction plate from the right side bottom of the appliance by removing the screw (N570-0008).
2. Install the box connector through the 7/8” (22.2mm) hole and into the junction plate.
6.1 hard-wiring installation