W415-2107 / B / 10.31.19
EN
10
installation
Measurements are taken from the front trim
Bottom
0”
Sides
0”
Front / Back
36” (914mm)
Mantel
8” (203mm)
•
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discoloration.
!
WARNING
2.2
grounding the appliance
2.3
minimum clearance to combustibles
2.4
minimum mantel clearances
MANTEL
8”
(203mm)
WALL
8” (203mm)
L
1mm GAP
8” (203mm)
Trim
Clearance
3/8” (10mm)
minimum *
Finishing
materials
WALL
•
This appliance is for use with 120 volts and 240 volts.
•
A bonded/grounded power source is
mandatory
for this appliance.
•
This appliance must be connected to a dedicated 15 amp circuit. The use of an extension cord is
NOT
permitted.
!
WARNING
* If fi nishing materials are installed on top of the already 8” (203mm) wall, a 3/8” (10mm) clearance must be
maintained at the top of the trim in order to service the appliance.
note: