![background image](http://html.mh-extra.com/html/napoleon/bipro665rb/bipro665rb_service-manual_3455088020.webp)
20
EN
www.napoleongrills.com
N415-0424 OCT 23.17
BIPRO665 BUILT-IN INSTRUCTIONS
4” (102mm) minimum, bottom of the
grill to top of the electrical panel.
8” (203mm)
maximum
7”
(178mm)
9⅝”
(244mm)
LOCATED INSIDE CABINET
GFI Outlet
WARNING!
Failure to follow these instructions could result in property damage, personal injury or
death.
The grills electrical systems are pre assembled in an electrical box which must be mounted a minimum
of 4” (102 mm) below the bottom of the grill as illustrated. Fasten the electrical box to the inside of the
enclosure, making sure the ventilation holes are not obstructed.
Plug the power supply into a Ground Fault Interrupter (GFI) protected circuit. Never remove the the
grounding plug or use with an adapter of 2 prongs.