5
EN
www.napoleon.com
N415-0542CE-GB-DE OCt 03.19
Technical Data
the following table lists input values for the appliance.
Burner
Orifice Size
(Gross) Heat
Input (Total)
Gas Usage (Total)
I
II
I/II
I
II
Main
#60
1.45mm
19.0 kW
1383 g/hr
1805 L/hr
Rear
1.25mm
#50
5.5 kW
400 g/hr
522 L/hr
Smoker
#67
#56
2.5 kW
182 g/hr
237 L/hr
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table
above. The grill is equipped with an internal regulator. This internal regulator has an outlet pressure of 24.5
mbar for propane/butane and 18.5 mbar for natural gas and must not be modified or adjusted. For replace
-
ment, use only the regulator specified by the manufacturer.
this unit includes an internal regulator which stabilizes the gas pressure and improves grill performance.
this regulator cannot be adjusted. there is a pressure tap located on the side of the regulator. It can
be used by a qualified service person when servicing the grill to determine if the regulator is functioning
properly. The screw within the pressure tap must always be kept tight, except when performing a pressure
test on the regulator (qualified service personnel only).
Gas Category
I
3B/P(30)
I
3+(28-30/37)
I
3B/P(37)
I
3B/P(50)
I
2H
I
2E
I
2E+
Orifice Sizes(see
above)
I
I
I
I
II
II
II
Gases / Pressures
Butane and
Propane at
30mbar
Butane 28-30mbar
Propane 37mbar
Butane and
Propane at
37mbar
Butane and
Propane at
50mbar
G20 at
20mbar
G20 at
20/25 mbar
G20/G25 at
20/25 mbar
Countries
BE, BG, CY,
DK, EE, FI,
FR, GB, HR,
HU, IS, It, Lt,
LU, Mt, NL,
NO, RO, SE,
SI, SK, tR
BE, CH, CY, CZ, ES,
FR, GB, GR, IE, It,
Lt, LU, LV, Pt, SK, SI
PL
At, CH, DE,
SK
At, BG, CH,
CZ, DK, EE,
ES, FI, GB,
GR, HR, HU,
IE, IS, It, LV,
Lt, NO, Pt,
RO, SE, SI,
SK, tR
DE, LU, PL
BE,FR
Summary of Contents for BIPRO 665-3
Page 21: ...21 EN www napoleon com N415 0542CE GB DE Oct 03 19 ...
Page 24: ...24 EN www napoleon com N415 0542CE GB DE Oct 03 19 COUNTER TOP REQD NOT INCLUDED IM UGC665 ...
Page 26: ...26 EN www napoleon com N415 0542CE GB DE Oct 03 19 x1 x1 x2 x1 5 LOCATED INSIDE CABINET 6 7 ...
Page 27: ...27 EN www napoleon com N415 0542CE GB DE Oct 03 19 3 1 2 Wind Deflector Assembly Instructions ...
Page 52: ...52 DE www napoleon com N415 0542CE GB DE Oct 03 19 ...
Page 57: ...57 DE www napoleon com N415 0542CE GB DE Oct 03 19 x1 x1 x2 x1 5 INSIDE Schrank 6 7 ...
Page 59: ...59 DE www napoleon com N415 0542CE GB DE Oct 03 19 Windschutz Montageanleitungen 3 1 2 ...
Page 67: ...67 www napoleon com EN N415 0542CE GB DE Oct 03 19 ...