10.0 OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be elec-
trically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 C
ANADIAN
ELECTRICAL
CODE
in Canada or the
ANSI/NFPA 70
NATIONAL
ELECTRICAL
CODE
in the United States.
Remove the blower from its mounting bracket and attach to the bracket supplied with
the appliance. This bracket is found secured on the mounting stud located at the bot-
tom of the vent side wall. The blower bracket contains two holes that allow the blower
to be positioned away from the intended gas supply hole.
Position the vibration reducing pad,
centred, onto the threaded stud, piercing
a hole into the pad. The blower must be
able to be positioned entirely onto the pad.
Tilt the blower onto its side and slide it
past the controls. Position the blower
under the clip and onto the stud. Secure
with a wing nut.
Remove the "Z" shaped mounting bracket secured to the burner, by the pilot. Re-
move the thermal switch from the bracket supplied in the blower kit and attach to
the mounting bracket. Attach the connectors from the black and white wires to the
thermal switch. Replace bracket and switch in the location it was removed from.
BGNV / BCNV ONLY:
Remove the bracket from the top right side of the fi rebox. Remove the
thermal switch from the bracket supplied in the blower kit and
install the thermal switch into the bracket removed from the
fi rebox top. Then replace the bracket / switch in the location it
was removed.
Connect the two ends of the unattached wires by the bracket to
the thermal switch.
Connect the opposite ends of the wires to the red and black
leads of the blower harness.
Do not overtighten thermal switch or distort housing. Attach the connectors from the black and red wires to the blower.
Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.
black
white
red
BLOWER
THERMAL
SWITCH
VARIABLE
SPEED
SWITCH
MOUNTING
BRACKET
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
CONTACT WITH MOVING OR HOT OBJECTS.