Napoleon BGD36CFGN Installation And Operating Instructions Manual Download Page 40

40

W415-0661 / 12.07.07

72*  W175-0001         4" COUPLER 
73* W175-0013 

7" 

COUPLER

74*  W615-0044 

FIRESTOP SPACER - FLEXIBLE VENTING

75*  W500-0103 

TERMINAL EXTENSION PLATE

76 GD-301 

HEAT 

GUARD

77* W010-0370 

WALL 

SUPPORT 

ASSEMBLY

78*  W175-0053 

DURA-VENT ZERO CLEARANCE ADAPTOR  

79 VS47KT 

VENT 

SLEEVE

80 

W170-0063 

VENT PIPE COLLAR

81 

W585-0072 

VENT PIPE SHIELD

82*  W175-0159 

CONVERSION KIT - 

NG

 

TO

 

LP

83*  W175-0164 

CONVERSION KIT - 

LP

 

TO

 

NG

84*  GD831KT 

DECORATIVE BRICK PANELS - 

SANDSTONE

85* CDV202-PB 

DOOR 

TRIM 

KIT

86* GD-565-1KT 

SAFETY 

SCREEN

87*  S36WN 

WAVE SURROUND - 

BROWN

87*  S36WP 

WAVE SURROUND - 

PEWTER

87*  S36CCN 

CONCAVE SURROUND - 

BROWN

87*  S36CCP 

CONCAVE SURROUND - 

PEWTER

87*  S36CVN 

CONVEX SURROUND - 

BROWN

87*   S36CVP 

CONVEX SURROUND - 

PEWTER

88*  CFT36W 

UPPER TRIM FOR WAVE SURROUND

88*  CFT36CC 

UPPER TRIM FOR CONCAVE SURROUND

88*  CFT36CV 

UPPER TRIM FOR CONVEX SURROUND

Contact your dealer for questions concerning prices and avail-
ability of replacement parts. Normally all parts can be ordered 
through your Napoleon® dealer or distributor. 

When ordering replacement parts always give the following 
information:

 

1.  M

ODEL

 & S

ERIAL

 N

UMBER

 

OF

 

FIREPLACE

 

2.  I

NSTALLATION

 

DATE

 

OF

 

FIREPLACE

 

3.  P

ART

 N

UMBER

 

4.  D

ESCRIPTION

 

OF

 

PART

 

5.  F

INISH

 

 6. 

 

T

OP

 

OR

 

REAR

 

VENT

 

 

COMMON REPLACEMENTS

COMMON COMPONENTS:

COMMON ACCESSORIES:

BGD36CF(G) FLEXIBLE VENT KITS: 

BGD36CF(G) TERMINAL KITS: 

BGD36CF(G) ROOF TERMINAL KITS:

BGD36CF(G) COMPONENTS:

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FURTHER

 

INFORMATION

CONTACT

 

YOUR

 N

APOLEON

® 

DEALER

.

# PART 

NO. 

DESCRIPTION 

1 W357-0001  PIEZO 

IGNITER 

2 W680-0004  THERMOPILE 
3 W680-0005  THERMOCOUPLE** 

W010-0800 

PROPANE GAS PILOT ASSEMBLY

W010-0801 

NATURAL GAS PILOT ASSEMBLY 

W455-0069 

NATURAL GAS PILOT INJECTOR

W455-0067 

PROPANE GAS PILOT INJECTOR

W725-0025 

NATURAL GAS VALVE 

W725-0026 

PROPANE GAS VALVE 

7* W385-0334  NAPOLEON® 

LOGO

8* 

W750-0112 

20FT OF WIRE

9* W361-0016  GLOWING 

EMBERS

10* W550-0001 

CHARCOAL 

EMBERS

** WARNING: THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTE-
GRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING 
THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.

29*  W225-0058 

BLACK DOOR FRAME

30 

W455-0048 

#47  NATURAL GAS ORIFICE 

30 

W455-0047 

#56  PROPANE GAS ORIFICE

31* W010-0370 

WALL 

SUPPORT 

ASSEMBLY

32 W010-0539 

FLUE 

PIPE 

ASSEMBLY 

c/w 

GASKET

33*  W010-0538 

FLUE CAP c/w GASKET

34 W010-0764 

PAN 

BURNER 

35 GL-639 

LOG 

SET

36 

W135-0183 

BACK LOG (#1) 

37 

W135-0184 

LEFT MIDDLE LOG (#2) 

38 

W135-0185 

RIGHT MIDDLE LOG (#3)

39 

W135-0186 

LEFT CROSSOVER LOG (#4) 

 

40 

W135-0187 

MIDDLE CROSSOVER LOG (#5)

41 

W135-0188 

RIGHT CROSSOVER LOG (#6) 

42 W010-0454 

GLASS 

c/w 

GASKET

43 

W010-0516 

BLACK DOOR C/W GLASS

44 W010-1774 

FIRESTOP 

SPACER

 

GD220 (5 FT) 

57*  W010-0397 

4" FLEXIBLE VENT PIPE - (5 

FT

C

/

W

 

SPACERS

58*  W410-0017 

7" FLEXIBLE VENT PIPE - (5 

FT

)

 

GD330 (10 FT)

59*  W410-0018 

7" FLEXIBLE VENT PIPE - (10 

FT

)

60*  W010-0300 

4" FLEXIBLE VENT PIPE - (10 

FT

C

/

W

 

SPACERS

61* W010-0370 

WALL 

SUPPORT 

ASSEMBLY

62 

PERISCOPE 

  

-  

GD201

63 

WALL TERMINAL KIT  

-  

GD222

64* 1/12 

TO 

7/12 

PITCH 

GD110

65* 8/12 

TO 

12/12 

PITCH 

GD111

66* FLAT 

ROOF 

 

GD112

67*  W490-0073 

4/7 INNER/OUTER SLEEVE

68 W670-0006 

4/7 

TERMINAL

69 W170-0063 

STORM 

COLLAR

70 W010-0453 

ROOF 

SUPPORT

71 

W263-0054 /  

ROOF FLASHING

 W263-0055 

 W263-0056

11*  W573-0007 

10.3OZ TUBE HIGH TEMP SEALANT

12* W690-0001 

MILLIVOLT 

THERMOSTAT

13*  W690-0010B 

REMOTE CONTROL - Advantage 

14* W660-0011B  REMOTE 

CONTROL 

A

DVANTAGE

 P

LUS

15* GD65 

FAN 

KIT

16 GZ550-1KT 

BLOWER 

KIT

17* B440-KT 

BLOWER

18*  W500-0033 

VARIABLE SPEED SWITCH WALL MOUNTING PLATE

19*  W690-0005 

THERMOSTAT, 110 VOLT for use with ga-566

20* W660-0026 

PROGRAMMABLE 

TIMER

21 GA-566 

HOT 

AIR 

KIT

22 

GA-72 

HOT AIR EXHAUST KIT

23 GA-70 

EXTENSION 

KIT 

5

FT

24*  ANI-K 

ANDIRONS - BLACK

25*  ANI-G 

ANDIRONS - GOLD PLATED

26*  270 

PAINT, BLACK - 13OZ

27* W361-0014 

VERMICULITE

28* GD36 

THERMOSTATIC SENSOR CONTROL KIT 

 

 

FOR

 

USE

 

WITH

 

GD

65 

ONLY

BGD36CF(G) ACCESSORIES:

BGD36CF(G) REPLACEMENTS

BGD36CFG COMPONENTS: 

45 W100-0102 

BURNER 

TUBE

46*  W300-0102 

CLEAR GLASS EMBERS

47* W010-1835 

GLASS 

EMBER 

TRAY

48* W387-0004 

HIGH 

TEMPERATURE 

LIGHT 

ASSEMBLY

49*  W387-0006 

HALOGEN BULB 10W T320

50*  W725-0032 

DEXEN VALVE EI NATURAL GAS

51*  W725-0049 

DEXEN VALVE 3V PROPANE

52 

W455-0049 

PILOT INJECTOR - LP

53 

W455-0071 

PILOT INJECTOR - NG

54 W720-0092 

PILOT 

TUBE

55 

W100-0069 

PILOT ASSEMBLY - NG

56 

W100-0093 

PILOT ASSEMBLY - LP

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Summary of Contents for BGD36CFGN

Page 1: ...AFTEY INFORMATION Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do no...

Page 2: ...burns or clothing ignition Supervise young children when they are in the same room as the fireplace Clothing or other flammable material should not be placed on or near the fireplace Due to high tempe...

Page 3: ...h as blowers gas valves thermal switch switches wiring remote controls ignitor gasketing and pilot assembly are covered and NAPOLEON will provide replacement parts free of charge during the first year...

Page 4: ...B149 Installation Codes Mobile home installation must conform with local codes or in the absence of local codes install to the current standard for gas equipped mobile housing CAN CSA ZA240 MH Series...

Page 5: ...S INLET FIGURE 5 INSTALLATION OVERVIEW FIGURE 7 See the section MINIMUM MANTEL AND ENCLOSURE CLEARANCES Side Wall See the section INSTALLATION FRAMING See the section VENTING and INSTALLATION See the...

Page 6: ...may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the replace ue collar which must be sealed usi...

Page 7: ...7 W415 0661 12 07 07 FIGURE 8 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 8: ...se is a minimum 3 feet and a maximum 40 feet from the centre of the replace ue outlet NOTE When terminating vertically the restrictor plate W500 0205 must be installed Refer to Restricting Vertical Ve...

Page 9: ...run in addition to the 45 offset In this case zero rise is acceptable when using rigid See FIGURE 18 Flexible venting must maintain a 6 rise See FIGURE 19 PERISCOPE TERMINATION CORNER TERMINATION BGD...

Page 10: ...mum of 40 feet Horizontal run verti cal rise to maximum of 24 75 feet 4 2 times the verti cal rise equal to or greater than the horizontal run Vertical rise is equal to or greater than the horizontal...

Page 11: ...HT The shaded area within the lines represents acceptable values for HT and VT for the following symbols used in the venting calculations and examples are greater than equal to or greater than less t...

Page 12: ...TICAL RISE IN INCHES VT HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT when HT VT Simple venting con guration only one 90 elbow...

Page 13: ...s FIGURE 25 H2 V1 V2 H3 90 90 90 90 H1 FIGURE 26 Example 5 V1 4 ft V2 1 5 ft VT V1 V2 4 1 5 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows one 45 elbow 9...

Page 14: ...30 MAXIMUM VERTICAL R I S E I N FEET VT HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT For vent con gurations requiring more tha...

Page 15: ...90 6 75 ft HT HR HO 12 75 6 75 19 5 ft HT VT 19 5 6 5 26 ft Formula 1 HT 3VT 3VT 3 x 6 5 19 5 ft 19 5 19 5 Formula 2 HT VT 40 feet 26 40 Since both formulas are met this vent con guration is accept ab...

Page 16: ...HT VT Simple venting con guration only one 45 and 90 elbow See graph to deter mine the required vertical rise VT for the required horizontal run HT REQUIRED VER TICAL RISE IN INCHES VT HORIZONTAL VEN...

Page 17: ...VT Formula 2 HT VT 40 feet Example 3 90 90 90 H1 V1 V2 45 H2 V1 5 ft V2 10 ft VT V1 V2 5 10 15 ft H1 3 ft H2 2 5 ft HR H1 H2 3 2 5 5 5 ft HO 03 one 45 elbow three 90 elbows 135 03 45 90 90 90 135 5 4...

Page 18: ...ceptable Formula 2 HT VT 40 feet 15 9 40 Since only formula 2 is met this vent con guration is unac ceptable and a new replace location or vent con guration will need to be established to satisfy both...

Page 19: ...combustibles is required Use restop spacer W010 1778 supplied VERTICAL VENT SECTIONS A minimum of 1 all around the vent pipe on all vertical runs to combustibles is required Use restop spacer W500 00...

Page 20: ...d secure over the opening in the ceiling A restop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through VERTICAL INSTALLATION BGD36CF G 9 3 4...

Page 21: ...the exible vent pipe through the restop maintaining the required clearance to combus tibles Holding the air terminal let tering in an upright readable position secure to the exterior wall and make wea...

Page 22: ...d upper edge of the shingles Ensure that the air terminal is properly centered within the ashing giving a 3 4 margin all around Fasten to the roof Do NOT nail through the lower portion of the ashing M...

Page 23: ...the type s of gas indicated on the rating plate Aconversion kit is supplied with the mobile home appliance This Mobile Manufactured Home listed appliance comes factory equipped with means to secure t...

Page 24: ...W010 1774 supplied with the unit must be used to maintain this clearance VERTICAL VENT SECTIONS A minimum of 1 all around the vent pipe on all vertical runs to combustibles is required except for clea...

Page 25: ...LOW FOR PROPER DOOR REMOVAL 12 TO COMBUSTIBLE MANTLE The finishing material can be installed below the top opening a maximum of 1 1 2 Enough clearance to the door latches must be maintained to allow f...

Page 26: ...vertical runs to combustibles is required except for clearances in replace enclosures See MINIMUM ENCLOSURE CLEARANCES section Use restop spacer W500 0096 not supplied MINIMUM CLEARANCE TO COMBUSTIBLE...

Page 27: ...ON BGD36CF G ONLY OPTIONAL CLEAN FACE TRIM KIT INSTALLATION FIGURE 83 CLEAN FACE SURROUND MINIMUM ENCLOSURE CLEARANCES 3 First secure the clean face surround to the replace front by hooking the ledge...

Page 28: ...FIGURE 92c MINIMUM CLEARANCE TO COMBUSTIBLE CONSTRUC TION FROM FIREPLACE AND VENT SURFACES Combustible framing Top sides back and bottom of the unit 0 to stand offs Non combustible nishing Top 6 1 2...

Page 29: ...8 5 Place the bottom of the right crossover log 6 against the right rebox side and pulled forward to the grate The top of the log should rest in the pocket provided on the center log 5 BGD42CF FINISHI...

Page 30: ...e glowing embers for a maximum glowing effect Log colours may vary During the initial use of the replace the colours will become more uniform as colour pigments burn in during the heat activated curin...

Page 31: ...the rebox 3 Unscrew the lens cover making sure the gasket stays in place Note Do not handle the lamp bulb with bare ngers protect with a clean dry cloth 4 The lamp will pull straight outofthesocket R...

Page 32: ...k washer and wing nut provided Ensure that the blower does not touch the replace base or the rebox 5 Remove the 8 perimeter screws as illustrated in Fig 112 and lift out the burner base The gas line e...

Page 33: ...th moving or hot objects To ease installation of the fan remove the hinge screen and valve control door lower louvres from the base of the replace Position the vibration reducing pad into the clip and...

Page 34: ...nd solid core wire through the electrical hole located at the bottom left side of the unit FIGURE 125 BATTERY HOLDER GAS VALVE PILOT ASSEMBLY IGNITION MODULE PILOT GAS LINE Orange I through independen...

Page 35: ...s on wire size WIRE SIZE MAX LENGTH 14 gauge 100 feet 16 gauge 60 feet 18 gauge 40 feet A 20 length of millivolt wire is connected to the gas valve for the light wall switch However if a greater lengt...

Page 36: ...Im mediately call a quali ed service technician to inspect the replace and replace any part of the control system and any gas control which has been under water WARNING The gas valve has an interlock...

Page 37: ...POWER TO THE FIREPLACE IF SERVICE IS TO BE PERFORMED 3 TURN MANUAL SHUTOFF VALVE CLOCKWISE TO OFF DO NOT FORCE NEXT STEP 8 CLOSE THE GLASS DOOR 9 TURN MANUAL SHUTOFF VALVE COUNTER CLOCKWISE TO ON 10 T...

Page 38: ...re the glass embers are away from the center of the screen exposing the burner before lifting glass ember tray out When replacing burner absolutely no glass can be in cup surrounding the ori ce HINT I...

Page 39: ...ly perform a visual check of the pilot and the burner ames Compare them to the gures shown If any ames appear abnormal call a service person FIGURE 137 It is important to periodically perform a visual...

Page 40: ...F STEEL LTD 29 W225 0058 BLACK DOOR FRAME 30 W455 0048 47 NATURAL GAS ORIFICE 30 W455 0047 56 PROPANE GAS ORIFICE 31 W010 0370 WALL SUPPORT ASSEMBLY 32 W010 0539 FLUE PIPE ASSEMBLY c w GASKET 33 W010...

Page 41: ...8 PERISCOPE GD401 109 WALL TERMINAL KIT GD422 BGD42CF ROOF TERMINAL KITS 110 1 12 TO 7 12 PITCH GD410 111 8 12 TO 12 12 PITCH GD411 112 FLAT ROOF GD412 113 W490 0074 5 8 INNER OUTER SLEEVE 114 W670 00...

Page 42: ...42 W415 0661 12 07 07 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 43: ...rom the I terminal on the module If no spark the I terminal module must be replaced If there is a spark the I terminal is ne Inspect pilot assembly for a shorted wire or cracked insulator around the e...

Page 44: ...lve Conduct the following test to verify if the problem is the module or valve To measure voltages turn multimeter to DC place the red lead from multimeter on the screw on the terminal block for the w...

Page 45: ...ased The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool System is not...

Page 46: ...s been adhered to for any horizontal vent ing Air shutter has become blocked ensure air shutter opening is free of lint or other obstructions Flames are consist ently too large or too small Carboning...

Page 47: ...replace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name NorthlineExpress com http www northlinee...

Page 48: ...48 W415 0661 12 07 07 NOTES NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Reviews: