![Napoleon BGD36CFGN-1 Installation And Operating Instructions Manual Download Page 34](http://html1.mh-extra.com/html/napoleon/bgd36cfgn-1/bgd36cfgn-1_installation-and-operating-instructions-manual_3711254034.webp)
34
W415-1361 / 11.28.14
EN
The appliance requires a minimum enclosure height of 40 1/2" (1029mm) (REAR VENT) 49" (1245mm) (TOP
VENT). For temperature requirements, the enclosure space around and above the appliance must be left
unobstructed.
** See "VENTING" section.
6.3 MINIMUM ENCLOSURE CLEARANCES
24 1/2"
622mm
MINIMUM
PLUS RISE**
40 1/2"
1029mm
34"
864mm
2"
51mm
1"
25mm
2"
51mm
0” IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND STONE
6 1/2" 165mm
NON-COMBUSTIBLE
COMBUSTIBLE
SHELF
TOP OF
COMBUSTIBLE
ENCLOSURE
6.3.1 REAR VENT ENCLOSURE