background image

24

W415-1361 / 11.28.14

EN

5.4  USING FLEXIBLE VENT COMPONENTS

5.4.1 HORIZONTAL AIR TERMINAL INSTALLATION

For safe and proper operation of the appliance, follow the venting 
instructions exactly.
All inner 

fl

 ex pipe and outer 

fl

 ex pipe joints may be sealed using high 

temperature sealant W573-0002 (not supplied) or the high temperature 
sealant W573-0007 Mill Pac (not supplied).  However, the high temperature 
sealant W573-0007 Mill Pac (not supplied) must be used on the joint 
connecting the inner 

fl

 ex pipe and the exhaust 

fl

 ue collar.

Use only approved  fl exible vent pipe kits marked:

“Wolf Steel Approved Venting” as identifi ed 
by the stamp only on the outer fl ex pipe.

22.1

ELBOW

SPACERS

DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. 

KEEP IT PULLED TIGHT. 

SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN 
AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED 

AT THE START, MIDDLE AND END OF EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS 

MUST NOT BE REMOVED. 

!

WARNING

A.

 

Stretch the inner 

fl

 ex pipe to the required length taking into 

account the additional length needed for the 

fi

 nished wall 

surface. Apply a heavy bead of the high temperature 
sealant W573-0007 Mill Pac (not supplied) to the inner 
sleeve of the air terminal. Slip the vent pipe a minimum 
of 2” (50.8mm) over the inner sleeve of the air terminal 
and secure with 3 #8 screws. 

B.

 

Using the outer 

fl

 ex pipe, slide over the outer combustion 

air sleeve of the air terminal and secure with 3 #8 screws. 
Seal using high temperature sealant W573-0002 (not 
supplied).

C.

 

Insert the vent pipes through the 

fi

 restop maintaining the required 

clearance to combustibles. Holding the air terminal (lettering in 
an upright, readable position), secure to the exterior wall and 
make weather tight by sealing with caulking (not supplied).

D.

 

If more vent pipe needs to be used to reach the 

fi

 replace, couple 

them together as illustrated. The vent system must be 
supported approximately every 3 feet (0.9m) for both vertical 
and horizontal runs. Use noncombustible strapping to 
maintain the minimum clearance to combustibles.  

The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth 
of its return fl ange.

23.1B

SCREWS

#10x2"

2" (50.8mm) OVERLAP

OUTER FLEX PIPE

INNER FLEX

    PIPE

HIGH TEMPERATURE

SEALANT

CAULKING

HI-TEMP

SEALANT

#8 X 1/2” SELF DRILLING 

SCREWS 

INNER COUPLER

OUTER COUPLER

OUTER 

FLEX PIPE

INNER 
FLEX PIPE

OUTER 

FLEX PIPE

Summary of Contents for BGD36CFGN-1

Page 1: ...lectrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the...

Page 2: ...VENT COMPONENTS 26 5 5 1 HORIZONTAL AIR TERMINAL INSTALLATION 26 5 5 2 EXTENDED HORIZONTAL AND CORNER TERMINAL INSTALLATION 26 5 5 3 VERTICAL AIR TERMINAL INSTALLATION 27 5 6 VERTICAL THROUGH EXISTIN...

Page 3: ...ion GD36M GLASS FRONT INSTALLATION REMOVAL SAFETY BARRIER 12 3 BGD36CFG FLAME CHARACTERISTICS 50 12 2 2 BGD36CFG VENTURI ADJUSTMENT 50 12 4 FLAME CHARACTERISTICS 51 13 0 MAINTENANCE 51 13 1 ANNUAL MAI...

Page 4: ...no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this appliance if any part has...

Page 5: ...unless the unit is a direct vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PROVIDE ADEQUATE CLE...

Page 6: ...ical code in the United States We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specia...

Page 7: ...EXTENSIONS REFERER AU MANUEL D INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES SEE OWNER S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS REFERER AU MANUEL D INSTALLATION DE PROPRIETAIRE POUR LE...

Page 8: ...CH ELBOW TO ENSURE THIS GAP IS MAINTAINED THESE SPACERS MUST NOT BE REMOVED Use only Wolf Steel Simpson Dura Vent Selkirk Direct Temp American MetalAmerivent or Metal Fab venting components Minimum an...

Page 9: ...allowable horizontal run is 20 feet 6 1m The maximum allowable vertical vent length is 40 feet 12 2m The maximum number of vent connections is two horizontally or three vertically excluding the applia...

Page 10: ...10 W415 1361 11 28 14 EN 16 406MM MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM TOP VENT 10 254MM MINIMUM 34 864MM 42 3 8 1076MM MINIMUM PLUS RISE 24 610MM MAXIMUM See VENTING section 34 864MM...

Page 11: ...imum 12 304 8mm above grade The maximum allowable vent length is 10 3 1m for a fireplace and 8 2 4m for a stove 9 4A 12 305MM MIN TO GRADE 12 305MM MIN TO GRADE 3 3 2 CORNER TERMINATION The maximum ve...

Page 12: ...06mm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0 9m 3 0 9m See chart f...

Page 13: ...ical Termination Vertical rise is equal to or greater than the horizontal run Vertical rise is less than horizontal run Vertical rise is equal to or greater than the horizontal run Vertical rise is le...

Page 14: ...H1 H2 2 5 FT 0 8m 2 FT 0 6m 4 5 FT 1 4m HO 03 three 90 elbows 90 03 270 90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 6m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT 6 4m Formula 1 HT VT 9 9 FT 3m 11...

Page 15: ...both formulas are met this vent configuration is acceptable The shaded area within the lines represents acceptable values for HT and VT 90 V1 H1 H2 90 Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4 FT...

Page 16: ...within the lines represents acceptable values for HT and HT HT VT 16 3A For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 1...

Page 17: ...3_2B For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT 3 5VT Formula 2 HT VT 24 75 feet 7 5m Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4FT 1 2m 1...

Page 18: ...vent configurations requiring one or more 90 elbows top exit or one or more 90 elbows rear exit the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V1 5 FT 1 5m V2 6 FT...

Page 19: ...mulas apply Formula 1 HT 3 VT Formula 2 HT VT 40 feet 12 2m Example V1 2 FT 0 6m V2 1 FT 0 3m V3 1 5 FT 0 5m VT V1 V2 V3 2FT 0 6m 1FT 0 3m 1 5FT 0 5m 4 5 FT 1 4m H1 6 FT 1 8m H2 2 FT 0 6m HR H1 H2 6FT...

Page 20: ...1FT 0 3m 1FT 0 3m 10 75FT 3 3m 12 75FT 3 9m HO 03 four 90 elbows one 45 elbow 90 03 360 45 90 6 75 FT 2 1m HT HR HO 12 75FT 3 9m 6 75FT 2 1m 19 5 FT 5 9m HT VT 19 5FT 5 9m 6 5FT 2m 26 FT 7 9m Formula...

Page 21: ...e gasket needs only to be snug against the firebox WARNING FAILURE TO INSTALL THE CAP WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE 4 0 PRE INSTALLATION PREPA...

Page 22: ...SUPPLIED OR BLACK HIGH TEMP MILL PAC W573 0007 NOT SUPPLIED WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS...

Page 23: ...m your authorized dealer distributor See accessories to order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to...

Page 24: ...nt the additional length needed for the finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent p...

Page 25: ...ving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is...

Page 26: ...o greater than the depth of the return flange 26 1A SCREWS 10x2 OUTER RIGID PIPE CAULKING INNER RIGID PIPE SCREWS SELF DRILLING 8x1 2 1 25 4mm OVERLAP SEALANT HI TEMP 5 4 3 APPLIANCE VENT CONNECTION A...

Page 27: ...shingles above and to the sides of the air terminal connector Place the flashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air te...

Page 28: ...ectly off the appliance Follow vent manufacturer s installation instructions Different manufacturer s venting components must not be combined Once the preferred manufacturer s appliance adaptor has be...

Page 29: ...is supplied with the mobile home appliance Conversion Kits This appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Authorized dealer d...

Page 30: ...le material brick stone or ceramic tile may protrude in these areas WARNING RISK OF FIRE IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE...

Page 31: ...Finishing Sides bottom 0 to appliance edge Top 6 1 2 165mm Enclosure top 13 1 2 343mm to top of appliance Recessed depth 17 1 4 438mm Top sides and bottom of vent pipe 2 51mm Ceiling 54 1372mm from b...

Page 32: ...401 2 1029mm 11 2 38mm 14 356mm 171 4 438mm 401 2 1028mm MAX MIN 11 2 38mm MAX 383 4 984mm FOR TOP EXIT APPLICATIONS DO NOT BUILD INTO THIS AREA IT MUST BE LEFT CLEAR TO PRO VIDE ADEQUATE CLEARANCE FO...

Page 33: ...030mm MIN 171 4 438mm 401 2 1028mm 6 152 INSIDE CHASE OUTSIDE CHASE 401 2 1028mm 171 4 438mm THIS AREA MUST REMAIN EXPOSED TO ALLOW FOR PROPER DOOR OPERATION 12 305MM TO COMBUSTIBLE MANTLE IMPORTANT E...

Page 34: ...enclosure space around and above the appliance must be left unobstructed See VENTING section 6 3 MINIMUM ENCLOSURE CLEARANCES 241 2 622mm MINIMUM PLUSRISE 401 2 1029mm 34 864mm 2 51mm 1 25mm 2 51mm 0...

Page 35: ...E 49 1245mm 15 381mm 1 25mm NON COMBUSTIBLE COMBUSTIBLE SHELF COMBUSTIBLE MATERIAL 2 51mm 2 51mm 0 IFNON COMBUSTIBLE FINISHINGIS USEDSUCHAS BRICKANDSTONE STEELHEADER REQUIRED 34 864mm 61 2 165mm MINNO...

Page 36: ...UPPLIED CEMENTBOARD PANEL SUPPLIED COMBUSTIBLE MATERIAL SAFETY BARRIER When installing to a hearth the appliance riser must create a minimum clearance of 3 3 8 86mm PLUS the height of the hearth from...

Page 37: ...AL 0 0mm FINISH MATERIAL NON COMBUSTIBLE FACING MATERIAL FINISH MATERIAL 2 51mm 4 102mm 6 152mm 4 102mm 2 51mm 0 0mm 6 5 ALCOVE FRAMING APPLIANCE RECESS OR ALCOVE AREA NOTE Recesses or alcoves above t...

Page 38: ...OURATION 73 1 6 7 MINIMUM MANTEL CLEARANCES Position the remote receiver in the valve compartment close to the electrical junction box Ensure the receiver is on top of the placement label if equipped...

Page 39: ...LS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR IS...

Page 40: ...front by hooking the ledge that runs horizontally on the rear surface of the clean face surround over the bottom edge of the appliance front opening D With the clean face surround against the applianc...

Page 41: ...p sits flat on the burner C Position the front right log just behind the grate lining up the holes in the bottom with the studs located on the log support D Move the left log into position lining up t...

Page 42: ...KET WARNING RAK ROCK ADAPTOR KIT IS NECESSARY WITH THIS KIT REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE HEAT WILL CAUSE THEM TO EXPLODE A Remove all logs and media B Remove the 2 screws and log supp...

Page 43: ...over the burner ports may cause a Puffing sound To eliminate this sound simply push the media away from the burner ports NOTE The distribution of glass media over the burner ports will influence the...

Page 44: ...CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI NFPA NO 70 IN THE UNITED STATES ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE...

Page 45: ...h independent conduit BATTERY RELAY Red Black WIRE HARNESS NOTE WIRE TAGS ARE BRACKETED Brown SWI Black Red Green x2 TH Orange x2 THTP Black Yellow Blue Black TP MODULE PLUG RELAY PLUG Black Green Ora...

Page 46: ...seconds this will begin the rolling colour sequence C If you desire to lock one of the colours from the rolling colour sequence turn the light switch into the OFF position and then back into the ON po...

Page 47: ...be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob is d...

Page 48: ...touch any electric switch do not use any phone in your building 1 Stop Read the above safety information on this label 2 Turn remote wall switch to off position 3 Turn off all electrical power to the...

Page 49: ...E THERMOPILE This appliance has an air shutter that has been factory set open according to the chart below Regardless of venturi orientation closing the air shutter will cause a more yellow flame but...

Page 50: ...ING OPERATION LET THE APPLIANCE COOL COMPLETELY BEFORE CONDUCTING SERVICE WARNING NG LP BGD36CFG 0 1 4 6 4mm This appliance has an air shutter that has been factory set open according to the chart bel...

Page 51: ...Clean out any of the ports which may not be burning or are not burning properly D Check to see that the pilot flame is large enough to engulf the flame sensor and or thermocouple thermopile as well as...

Page 52: ...for pre cleaning Also gently remove any build up on the pilot assembly including if equipped thermopile thermocouple flame sensor and igniter NOTE The flame sensor may require to be cleaned using a fi...

Page 53: ...void any further damages F Remove the LED bar from the appliance and replace it with the new LED bar G To reinstall LED bar reverse these steps 13 3 GLASS LENS REPLACEMENT A Turn off all gas and elect...

Page 54: ...er clean as required If the glass is not kept clean permanent discoloration and or blemishes may result HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS W...

Page 55: ...ve the following information Model Serial Number of appliance Installation date of appliance Part number Description of part Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION C...

Page 56: ...AFETY BARRIER ASSEMBLY YES 12 1 2 4 3 5 6 7 8 9 13 14 15 16 18 11 10 17 20 19 W010 0516 DOOR ASSEMBLY W667 0018 GASKET TAPE X4 YES W562 0009 DOOR GASKET YES W300 0102 CLEAR GLASS 6lb 9 W090 0091 LEFT...

Page 57: ...W190 0022 CONTROL MODULE YES YES W010 2919 LED LIGHT STRIP HOUSING 14 21 14 22 14 23 14 27 14 25 14 24 14 26 14 28 14 30 14 31 14 14 14 38 14 14 36 14 35 14 34 14 14 33 14 32 14 14 29 24 26 23 22 21 2...

Page 58: ...CRIPTION W010 2377 CONVEX FRONT S36CVP STOCKED W010 1701 OPTIONAL TRIM CFT36CV W160 0094 FRONT CLIP X2 S36CVP MEGK BLACK GLASS EMBERS 1lb MEGB BLUE GLASS EMBERS 1lb MEGR RED GLASS EMBERS 1lb MEGA AMBE...

Page 59: ...eplace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch term...

Page 60: ...Gauge should read as described on the chart below Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak tes...

Page 61: ...wiring Troubleshoot the system with the simplest ON OFF switch Module is not grounded Verify the value and pilot assemblies are properly grounded to the metal chassis of the appliance or log set Pilo...

Page 62: ...e rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood the...

Page 63: ...s condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under the President s Limited Lifetime Warranty Policy are subject to a single claim During...

Page 64: ...ces Outdoor Fireplaces Gourmet Grills Fireplaces Heating Cooling call 705 721 1212 Grills call 705 726 4278 napoleonproducts com 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie...

Page 65: ...s L installation et l entretien doivent tre faits par un installateur qualifi une agence d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j instal e de...

Page 66: ...STALLATION DE LA TERMINAISON HORIZONTALE PROLONG E AJUSTABLE 91 5 5 3 INSTALLATION DE LA TERMINAISON VERTICALE 92 5 6 TERMINAISON VERTICALE TRAVERS UNE CHEMIN E EXISTANTE 93 5 7 INSTALLATION DANS UNE...

Page 67: ...PI CES PLAQU ES 119 14 0 RECHANGES 120 15 0 VUE D ENSEMBLE 121 16 0 L ASSEMBLAGE DE LA SOUPAPE 122 17 0 ACCESSORIES 123 18 0 GUIDE DE D PANNAGE 124 18 1 BGD36CF 124 18 2 BGD36CFG 126 19 0 GARANTIE 12...

Page 68: ...ins une fois l an par un sp cialiste en entretien Un entretien plus fr quent pourrait tre n cessaire en raison des peluches provenant des tapis literie etc L emplacement de l appareil doit tre gard li...

Page 69: ...Gas Code ANSI Z223 1 NFPA54 aux tats Unis Cet appareil convient pour installation dans une maison mobile si l installation est conforme aux normes actuelles pour les maisons mobiles quip es au gaz CA...

Page 70: ...FI Dans ce manuel toutes les sections du BGD36CF G concernent le BGD36CF BGD36CFG et GD36M 2 3 INFORMATION G N RALE POUR VOTRE SATISFACTION CET APPAREIL A T MIS L ESSAI POUR CONFIRMER SON FONCTIONNEME...

Page 71: ...ESSURE 10 WATER COLUMN PRESSION AU COLLECTEUR 3 5 D UNE COLONNE D EAU PRESSION AU COLLECTEUR 10 D UNE COLONNE D EAU MINIMUM SUPPLY PRESSURE 4 5 WATER COLUMN MINIMUM SUPPLY PRESSURE 11 WATER COLUMN PRE...

Page 72: ...DE CHAQUE COUDE AFIN DE MAINTENIR CET ESPACE VIDE N ENLEVEZ PAS CES ESPACEURS Utilisez uniquement des composants d vacuation Wolf Steel Simpson Dura Vent Selkirk Direct Temp American MetalAmerivent ou...

Page 73: ...vents permettent soit une vacuation verticale soit une vacuation horizontale de l appareil La course horizontale doit tre conserv e un maximum de 20PI 6 1m La hauteur totale permise pour un vent verti...

Page 74: ...1361 11 28 14 FR 16 406MM MINIMUM 40 PI 12M MAXIMUM 3 PI 1M MINIMUM 10 254MM MINIMUM 24 610MM MAXIMUM 34 864MM VACUATION SUR LE DESSUS 42 3 8 1076MM MINIMUM PLUS L L VATION Voir la section VACUATION 3...

Page 75: ...STALLATIONS PARTICULI RES D VENTS 3 3 1 ENSEMBLE P RISCOPIQUE 12 305MM MIN AU NIVEAU DU SOL 30 762MM MIN 30 762MM MIN 34 864MM 24 1 4 616MM 3 3 2 INSTALLATION EN COIN La longueur maximale du conduit d...

Page 76: ...des murs adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1...

Page 77: ...e est plus grande ou gale la course horizontale La course verticale est plus petite que la course horizontale La course verticale est plus grande ou gale la course horizontale La course verticale est...

Page 78: ...LE REQUISE EN PIEDS M TRES VT LONGUEUR DES COURSES HORIZONTALES PLUS LES D VIATIONS EN PIEDS M TRES HT Lorsque la configuration de l vacuation exige plus d un coude de 90 les formules suivantes s appl...

Page 79: ...7 5m Puisque les deux formules sont respect es cette configuration d vacuation est acceptable La section ombrag e l int rieur des lignes repr sente des valeurs acceptables pour HT et VT 90 V1 H1 H2 9...

Page 80: ...ion ombrag e l int rieur des lignes repr sente des valeurs acceptables pour HT et VT HT VT 16 3A Lorsque la configuration de l vacuation exige plus qu un coude de 90 les formules suivantess appliquent...

Page 81: ...0 3 3 5 1 1 19 25 5 9 Lorsque la configuration de l vacuation exige plus qu un coude de 90 les formules suivantes s appliquent Formule 1 HT 3 5VT Formule 2 HT VT 24 75 pieds 7 5m Exemple V1 4 PI 1 2m...

Page 82: ...acuation l arri re les formules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 5 PI 1 5m V2 6 PI 1 8m V3 10 PI 3 1m VT V1 V2 V3 5PI 1 5m 6PI 1 8m 10PI 3 1m 21PI 6 4m...

Page 83: ...es formules suivantes s appliquent Formule 1 HT 3 VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 2 PI 0 6m V2 1 PI 0 3m V3 1 5 PI 0 5m VT V1 V2 V3 2PI 0 6m 1PI 0 3m 1 5PI 0 5m 4 5PI 1 4m H1 6 PI 1 8m H2...

Page 84: ...3m 10 75PI 3 3m 12 75PI 3 9m HO 0 03 quatre coudes 90 un coude 45 90 0 03 360 45 90 6 75 PI 2 1m HT HR HO 12 75PI 3 9m 6 75PI 2 1m 19 5PI 5 9m HT VT 19 5 PI 5 9m 6 5 PI 2m 26 PI 7 9m Formule 1 HT 3 V...

Page 85: ...t sur le couvercle d vacuation pour assurer son tanch it Prenez soin de ne pas endommager le joint d tanch it B Retirez la plaque qui recouvre l ouverture du conduit d vacuation de 4 102mm qui se trou...

Page 86: ...AD QUATEMENT SOUTENU IL RISQUE DE FL CHIR OU DE SE S PARER UTILISEZ DES SUPPORTS DE CONDUIT ET RACCORDEZ LES SECTIONS DE CONDUITS SELON LES INSTRUCTIONS D INSTALLATION RISQUE D INCENDIE VITEZ QUE L IS...

Page 87: ...Une fois que vous aurez d termin l emplacement de la terminaison d coupez et charpentez une ouverture dans le plafond et le toit pour laisser le d gagement minimal de 1 25 4mm entre le conduit d vent...

Page 88: ...ourses verticales et horizontales Utilisez des supports incombustibles afin de maintenir le d gagement minimal aux mat riaux combustibles Les terminaisons ne doivent pas tre ench ss es dans un mur ou...

Page 89: ...9 1mm de connecteur de terminaison visible au dessus du haut du solin Glissez le solin sous les c t s et le bord sup rieur des bardeaux Assurez vous que le connecteur de terminaison est bien centr dan...

Page 90: ...avec le scellant Mill Pac 25 1A A Mettez l appareil en place Mesurez la longueur d vent requise entre la terminaison et l appareil en tenant compte de la longueur additionnelle n cessaire pour la surf...

Page 91: ...surez vous que tous les conduits int rieurs et les coudes aient suffisamment d espaceurs et que chaque composant est scell et fix solidement celui qui le pr c de Fixez le manchon t lescopique la cours...

Page 92: ...r de terminaison et glissez le sous les c t s et le bord sup rieur des bardeaux Assurez vous que le connecteur de terminaison est bien centr dans le solin en laissant une marge de 3 4 19 1mm tout auto...

Page 93: ...nstructions d installation du fabricant du syst me d vacuation Des composants d vacuation de diff rents fabricants ne doivent pas tre combin s Une fois que l adaptateur de votre choix est install le r...

Page 94: ...ez le B Si l appareil est muni d un raccord flexible celui ci est con u pour recevoir une conduite de gaz de 1 2 Sans raccord flexible l appareil est con u pour recevoir une conduite de gaz de 3 8 L a...

Page 95: ...TOUT AUTRE MAT RIAU COM BUSTIBLE BLOQUEZ L ENTR E DE L ENCEINTE POUR EMP CHER L INFILTRATION D ISOLANT SOUFFL ASSUREZ VOUS QUE L ISOLATION ET LES AUTRES MAT RIAUX SONT BIEN FIX S LORSQUE VOUS CONSTRUI...

Page 96: ...at riaux combustibles de 1 25mm est requis sour toutes les courses verticales l exception des d gagements l int rieur de l enceinte de l appareil Voir la section D GAGEMENTS MINIMAUX DE L ENCEINTE Uti...

Page 97: ...R LEDESSUS VACUATION L ARRI RE 401 2 1029mm 11 2 38mm 14 356mm MAX MIN 11 2 38mm MAX 171 4 438mm 401 2 1028mm 383 4 984mm POUR DES APPLICATIONS AVEC VACUATION SUR LE DESSUS NE CONSTRUISEZ RIEN DANS CE...

Page 98: ...30mm MIN 171 4 438mm 401 2 1028mm 6 152 ENCEINTE INT RIEURE ENCEINTE EXT RIEURE 401 2 1028mm 171 4 438mm CETTE SECTION DOIT DEMEURER D GAG E POUR PERMETTRE L OUVERTURE AD QUATE DE LA PORTE 12 305MM LA...

Page 99: ...de l enceinte autour de l appareil et au dessus doit demeurer sans obstruction R f rez vous la section VACUATION 6 3 D GAGEMENTS MINIMAUX DE L ENCEINTE 6 3 1 ENCEINTE DE L VACUATION L ARRI RE 2 51mm...

Page 100: ...5mm 2 51mm 2 51mm 0 SIUNMAT RIAUDE FINITIONINCOMBUSTIBLE ESTUTILIS TELQUEDELA BRIQUEETDELAPIERRE INCOMBUSTIBLE COMBUSTIBLE TABLETTE 49 1245mm 15 381mm 34 864mm 61 2 165mm DEMAT RIAU INCOMBUSTIBLE 43 1...

Page 101: ...DE PROTECTION 6 3 4 INSTALLATION DE LA BASE DE PROTECTION Lorsque la base d l vation est install e sur une base de protection un d gagement minimal de 3 3 8 86mm PLUS la hauteur de la base de protect...

Page 102: ...mm 2 51mm 0 0mm INCOMBUSTIBLE 2 51mm 4 102mm 6 152mm 4 102mm 2 51mm 0 0mm APPAREIL ZONE ENCASTR E OU ALC VE NOTE Les zones encastr es ou les alc ves au dessus de l appareil peuvent tre aussi profondes...

Page 103: ...OLORATION 73 1 35 25 PLACER LE T L COMMANDE SUR CETTE TIQUETTE BASE DU FOYER BO TE DE D RIVATION Positionner le t l commande aux compartiment du soupape pr s du boite de d rivation lectrique Assurez v...

Page 104: ...FROID AU TOUCHER LES PORTES SONT LOURDES ET FRAGILES MANIPULEZ AVEC SOIN 75 1 7 0 FINITION Ouvrez la porte en d verrouillant les loquets sup rieur et inf rieur situ s du c t droit de la porte NOTE Ce...

Page 105: ...de l appareil en accrochant le rebord horizontal l arri re du contour par dessus la bordure inf rieure de la fa ade de l appareil D Lorsque le contour repose contre la fa ade de l appareil accrochez...

Page 106: ...de l appareil les couleurs deviendront plus uniformes mesure que leurs pigments seront absorb s pendant le proc d de cuisson A Placez la b che arri re de sorte qu elle s appuie sur les deux supports...

Page 107: ...EUR RAK ROCK DOIT TRE UTILIS AVEC CET ENSEMBLE NE PAS UTILISER DE VRAIES ROCHES DANS CET APPAREIL LA CHALEUR LES FERA CLATER SUPPORT DE ROCHES SUPPORT B CHES A Enlevez tous les composants d coratifs e...

Page 108: ...RIFI ES SUR LE BR LEUR PLUS D UNE COUCHE DE BRAISES SUR LE BR LEUR AURA POUR EFFET DE FAIRE MONTER LA FLAMME ET DE CR ER DE LA SUIE AVERTISSEMENT 9 0 FINITION DU BGD36CFG 9 1 INSTALLATION DU BR LEUR P...

Page 109: ...SI UNE PARTIE QUELCONQUE A T SUBMERG E CONTACTEZ IMM DIATEMENT UN TECHNICIEN DE SERVICE QUALIFI POUR INSPECTER L APPAREIL POUR DES DOMMAGES AU CIRCUIT LECTRIQUE RISQUE DE CHOCS LECTRIQUES OU D EXPLOS...

Page 110: ...S SWI Noir Rouge Vert x2 TH Orange x2 THTP Noir Jaune Bleu Noir TP PRISE DU MODULE PRISE DU RELAIS Noir Vert Orange Noir 12 volts la lumi re de veille et l interrupteur de la lumi re de veille l inter...

Page 111: ...n ARR T puis tourner la position MARCHE dans trois secondes cela vont verrouiller ce couleur NOTE Apr s que les couleurs sont verrouill es changeant l interrupteur la position d ARR T puis la position...

Page 112: ...uple de se refroidir Durant l allumage et le r allumage le bouton de contr le du gaz ne peut tourner de PILOT OFF moins de l enfoncer l g rement 1 Arr tez Lisez les consignes de s curit ci dessus 2 Co...

Page 113: ...interrupteur lectrique n utilisez aucun t l phone dans votre immeuble 1 ARR TEZ Lisez les consignes de s curit sur l tiquette de fonctionnement 2 Mettez l interrupteur mural la position OFF 3 Coupez l...

Page 114: ...T N O L O T HI L O F F O A B VIS DE LA VEILLEUSE Pression Gaz Naturel pouces Gaz Naturel millibars Propane pouces Propane millibars Arriv e 7 min 4 5 17 4 mb min 11 2mb 13 min 11 32 4 mb min 27 4mb So...

Page 115: ...ant l injecteur mettez un nouveau sac dans l aspirateur et aspirez les braises Des braises vitrifi es de rechange peuvent tre command es aupr s de votre d taillant Wolf Steel lt e GN PL BGD36CFG GD36M...

Page 116: ...z vous que la flamme de la veilleuse est assez puissante pour envelopper la sonde de flamme et ou le thermocouple thermopile et qu elle atteigne le br leur E Remettez en place les b ches les roches ou...

Page 117: ...ez aussi tout d p t se trouvant sur l assemblage de la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de flamme et l allumeur NOTE Vous devrez possiblement nettoyer le c...

Page 118: ...le nouveaux la barre de LED G Pour r installer la barre de LED renverser les tapes au dessus 13 3 REPLACEMENT DE LENTILLE DE VITRE A Coupez l alimentation lectrique et du gaz l appareil B Enlevez la p...

Page 119: ...rement l aide d un linge propre et sec Nettoyez les deux c t s de la vitre avec un nettoyeur recommand apr s les dix premi res heures de fonctionnement Par la suite nettoyez aussi souvent qu il le fa...

Page 120: ...d le et num ro de s rie de l appareil Date d installation de l appareil Num ro de la pi ce Description de la pi ce Fini IDENTIFIE LES ARTICLES QUI NE SONT PAS ILLUSTR S POUR PLUS D INFORMATION CONTACT...

Page 121: ...10 17 20 19 W010 0516 ASSEMBLAGE DE LA PORTE W667 0018 BANDE DU JOINT D TANCH IT X4 OUI W562 0009 JOINT D TANCH IT DE LA PORTE OUI W300 0102 VERRE CLAIR 6lb 9 W090 0091 PANNEAU DE PORCELAINE DU C T GA...

Page 122: ...OUI W190 0044 BO TIER DE PILES 42 39 40 38 36 33 34 35 37 41 W432 0046 CONNECTEUR FLEXIBLE DU COLLECTEUR 3 8 W750 0193 FILS DE BR LEUR ON OFF 20 56 INJECTEUR DE VEILLEUSE PL 48 INJECTEUR DE VEILLEUSE...

Page 123: ...1 EN STOCK W010 1701 MOULURE OPTIONNEL CFT36CV W160 0094 AGRAFE AVANT X2 S36CVP MEGK BRAISES VITRIFI ES NOIR 1lb MEGB BRAISES VITRIFI ES BLEU 1lb MEGR BRAISES VITRIFI ES ROUGE 1lb MEGA BRAISES VITRIFI...

Page 124: ...gaz au br leur principal le bouton du gaz est HI l interrupteur mural thermostat est ON Le thermostat ou l interrupteur sont d fectueux Reliez un fil de d rivation entre les bornes de l interrupteur m...

Page 125: ...la pression comme d crit sur la diagramme ci dessous Assurez vous que le br leur prinicpal fonctionne HI APR S AVOIR PRIS LA LECTURE DES PRESSIONS ASSUREZ VOUS DE TOURNER FERMEMENT LA VIS VERS LA DRO...

Page 126: ...semble de b ches tincelle la veilleuse mais celle ci ne s allume pas Alimentation en gaz V rifiez si la soupape bille de la conduite d arriv e du gaz est Ouverte V rifiez si la pression d arriv e est...

Page 127: ...era le redressement du courant de la flamme V rifiez si le bon injecteur de veilleuse est install et que l alimentation en gaz est conforme aux sp cifications du manuel Souvenez vous que la flamme tra...

Page 128: ...la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de NAPOL ON Toutes les pi ces remplac es en vertu de la politique de Garantie vie limit e du Pr...

Page 129: ...11 28 14 FR Date 43 1 Probl mes particuliers Travail effectu Nom du technicien D taillant Historique d entretien Wolf Steel Cet appareil doit tre entretenu annuellement selon son usage 20 0 HISTORIQU...

Page 130: ...130 W415 1361 11 28 14 FR 44 1 21 0 NOTES...

Page 131: ...131 W415 1361 11 28 14 FR 44 1...

Page 132: ...s lectriques Foyers ext rieurs Grils gaz de qualit Foyers Chauffage et Climatisation Grils composez 514 737 6294 napoleonproducts com 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Roa...

Reviews: