1.3 information sur la plaque d’homologation
A
4"
B
2"
C
2"
TITLE:
RATING PLATE,. GDS25 (SB)
REVISION: A:
UPDATED CSAYEAR & DESCRIPTION || 08.16.17_C.L.
DWG#:
W385-1962
DATE:
06.11.14
W385-1962 / A
NOT FOR USE WITH SOLID FUEL
GDS25
PAGE 1 OF 2
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2016, CERTIFIED TO / CERTIFIE CSA 2.22-2016 VENTED DECORATIVE GAS APPLIANCE / FOYER À GAZ VENTILÉ.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
VENT TOP
2" TO CEILING FROM
VENT BOTTOM
1" STOVE TOP 48”
VENT SIDES
1"
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE AVEC CET APPAREIL
EVENT SUPERIEUR 2" ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR 1" ET LE PLAFOND 48”
COTES DE L'EVENT 1"
A
4"
B
2"
C
2"
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
SERIAL NUMBER / NO. DESERIE
WOLF STEEL LTD.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA
OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFAC-
TURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOR
USE WITH BARRIER W010-3295. FOLLOW THE INSTALLATION INSTRUCTIONS
LOCATED IN THE INSTALLATION MANUAL
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET
UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS
DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE
SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
POUR UNE
UTILISER AVEC BARRIÈRE W010-3295. SUIVEZ LES INSTRUCTIONS D'INSTALLATION
SE TROUVENT DANS LE MANUEL D'INSTALLATION.
MANIFOLD PRESSURE:
3.5” W.C. (NG)
PRESSION AU COLLECTEUR:
3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE:
4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN:
4.5"
D'UNE COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE:
7" W.C. (NG)
PRESSION D'ALIMENTATION MAX:
7"
D'UNE COLONNE D'EAU (GN)
AFUE:
64%
MANIFOLD PRESSURE:
10” W.C. (LP)
PRESSION AU COLLECTEUR:
10" D'UNE
COLONNE D'EAU(P)
MIN SUPPLY PRESSURE:
11" W.C.(LP)
PRESSION D'ALIMENTATION MIN:
11"
D'UNE COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE:
13" W.C. (LP)
PRESSION D'ALIMENTATION MAX:
13"
D'UNE COLONNE D'EAU (P)
AFUE:
64%
GDS25N
MODEL
GDS25P
0-2000ft
2000-4500ft
ALTITUDE / ELEVATION
0-2000ft
2000-4500ft
24,500 BTU/h
22,000 BTU/h
INPUT / ALIMENTATION
23,000 BTU/h
20,000 BTU/h
19,000 BTU/h
16,000 BTU/h
REDUCED INPUT /
16,000 BTU/h
14,000 BTU/h
ALIMENTATION REDUITE
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659
(WUSA)
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING:
DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
ELECTRICAL RATING:
115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. MINIMUM AND
MAXIMUM VERTICAL VENT LENGTHS ARE 3
FEET AND 40 FEET RESPECTIVELY.
MINIMUM AND MAXIMUM HORIZONTAL
VENT LENGTHS ARE 10 INCHES AND 20
FEET RESPECTIVELY. PROPER REINSTAL-
LATION AND RESEALING IS NECESSARY
AFTER SERVICING THE VENT-AIR INTAKE
SYSTEM.
UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
AVERTISSEMENT:
N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
CLASS.:
115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
MATERIAL:
CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
HOLE TO BE 0.250ӯ
BLACK ON WHITE BACKGROUND
MAX OVERALL DECAL SIZE:
8.5"x4.75"
SERIAL NUMBERS TO BE ASCENDING FROM GDS25/CDVS25007100
A
ÉCHANTILLON
Cette illustration est à titre de référence seulement. Consultez la plaque d’homologation pour obtenir l’information
précise.
note:
La plaque d’homologation doit rester avec l’appareil à tout instant. Il ne doit pas être enlevé.
1.4 installation dans une maison mobile
Cet appareil doit être effectuée en respectant les directives du fabricant et le Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, aux États-Unis, ou les normes actuelles pour les maisons
mobiles, CAN/CSA Z240 SÉRIE MH au Canada. Cet appareil ne doit être utilisé qu’avec le type de gaz indiqué
sur la plaque d’homologation.
Cet appareil homologué pour les maisons mobiles et préfabriquées possède des éléments de fi xation. L’appareil est
muni de deux trous de
¼
” (6,4mm) de diamètre, situés aux coins avant, gauche et droit de la base. Fixez à l’aide des
attaches appropriées, insérées dans les trous de la base. Pour les produits autoportante, contactez votre revendeur
agréé / distributeur permettant l’ensemble de sécurisation. Lors d’une installation dans une maison mobile, l’appareil
doit être fi xé au plancher. Éteignez toujours la veilleuse et l’alimentation en gaz à la source avant de déplacer la
maison mobile. Après avoir déplacé la maison mobile et avant d’allumer l’appareil assurez-vous que les bûches sont
placées correctement.
Cet appareil est certifi é pour être installé dans une maison mobile installée de façon permanente, sauf si les
codes locaux l’interdisent.
Cet appareil ne doit être utilisé qu’avec le type de gaz indiqué sr la plaque d’homologation. On ne peut utiliser
cet appareil avec d’autres types de gaz, sauf si un ensemble de conversion certifi é est utilisé.
Ensembles de conversion
L’appareil pour maison mobile peut être converti au gaz natural (GN) ou au propane (P).
Pour effectuer une conversion, veuillez consulter votre détaillant autorisé.
20.1
note:
Trousse de conversions ne sont pas disponibles pour les appareils de d’évent libre.
information générales
FR
W415-2207 /
C
/
08.23.18
59