background image

14

W415-0559 / 02.15.06

Main burner goes 
out; pilot stays on.

Pilot fl ame is not large enough 
or not engulfi ng the thermo-
pile

-  service or replace Oxygen Depletion Sensor System
- correct piping and/or regulator to provide correct pressure

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.
- replace Oxygen Depletion Sensor System / valve.

Remote wall switch wire is too 
long; too much resistance in 
the system.

-  shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

-  replace.

Pilot burning; no 
gas to main burner; 
gas knob is on ‘HI’; 
wall switch / ther-
mostat is on.

Themostat or switch is de-
fective.

-  connect a jumper wire across the wall switch terminals; if main burner 
lights, replace switch / thermostat.

M a i n   b u r n e r   o r i f i c e   i s  -  remove stoppage in orifi ce.

Faulty valve.

-  replace.

Wall switch wiring is defec-
tive.

-  disconnect wires from valve. Connect a jumper wire across terminals 
1 & 3; if the main burner lights, check the wires for defects and / or 
replace wires.

Pilot goes out when 
the gas knob is re-
leased.

The gas valve has 
an interlock device 
which will not al-
low the pilot burn-
er to be lit until 
the thermocouple 
has cooled. Allow 
approximately 60 
seconds for the 
thermocouple to 
cool.

S y s t e m   i s   n o t   c o r r e c t l y 
purged.

-  purge the gas line.

Thermocouple shorting / 
faulty.

-  loosen and tighten thermocouple.
-  clean thermocouple and valve connection.
-  replace Oxygen Depletion Sensor System
-  test and replace valve.

Faulty valve.

-  replace.

Out of propane gas.

-  fi ll the tank.

Pilot fl ame is not large enough. 
(Supply pressure too low.)

-  service or replace Oxygen Depletion Sensor System

ELECTRODE

PILOT
BURNER

THERMOCOUPLE

THERMOPILE

Pilot will not light.

-  check if pilot can be lit by a match
-  check that the wire is connected to the push button ignitor.
-  check if the push button ignitor needs tightening.
-  replace the wire if the wire insulation is broken or frayed.
-  replace the electrode if the ceramic insulator is cracked or broken.
-  replace the push button ignitor.

 No spark at pilot burner

-  fi ll the tank.

Out of propane gas

No gas at the pilot burner

-  check that the manual valve is turned on.
-  check the pilot orifi ce for blockage.
-  replace the valve / Oxygen Depletion Sensor System.
-  call the gas distributor.

Main burner goes 
out; pilot goes out.

Insuffi cient air supply

- open window or door. (Use one of the methods described in ANSI 
Z223.1 Section 5.3 or the applicable local code.)

Out of propane gas.

-  fi ll the tank.

Pilot fl ame is not large enough. 
(Supply pressure too low.)

-  service or replace Oxygen Depletion Sensor System
- correct piping and / or regulator to provide correct pressure.

TROUBLE SHOOTING GUIDE

SYMPTOM

PROBLEM

TEST SOLUTION

Summary of Contents for Arlington GVFS20N

Page 1: ...1 W415 0559 02 15 06 W415 0559 02 07 06...

Page 2: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified installer service agency or the gas supplier Follow the inst...

Page 3: ...service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The heater area must be kept clear and free from combustible materials gasoline and oth...

Page 4: ...cal breakage of PHAZER logs and embers nor any venting com ponents used in the installation of the replace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for...

Page 5: ...approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product WARNING This product must be installed by a licensed plumber or gas tter when installed w...

Page 6: ...then pivoting the box open 2 Remove the 4 AA batteries and replace using the new ones 3 Pivot the box closed and re secure using the screw re moved in step 1 19 1 4 9 5 8 25 3 8 15 3 4 STOVE SHOULD NO...

Page 7: ...wire to the black wire coming from below the unit 4 Insert the clips on the blower housing into the cutouts in the rear shield Push down to lock the clips into position 5 Secure the blower using the...

Page 8: ...remove CAST FRONT INSTALLATION AND REMOVAL 3 SCREWS BRACKET FRONT 2 SCREEN INSTALLATION AND REMOVAL 1 Unscrew the four screws one in each corner from the screen 2 Remove screen from unit Follow the a...

Page 9: ...moved see Cast Front Screen Removal in the Finishing section of this manual 1 Place the rear log as shown onto the rear log support brackets Bend the bracket on the right side to help retain the rear...

Page 10: ...turn the gas control knob Never use tools If the knob will not push in and turn by hand do not try to repair it Call a quali ed service technician Force or attempted repair may result in a re or expl...

Page 11: ...om the pilot housing Blow out the housing in the same direction as the gas ow Re install the injector and the pilot tube turn on the gas and check for leaks If this does not improve the performance re...

Page 12: ...NER ORIFICE NG 7 W455 0003 54 BURNER ORIFICE LP 10 W662 0001 NG OXYGEN DEPLETION SENSOR SYSTEM 10 W662 0005 LP OXYGEN DEPLETION SENSOR SYSTEM 12 W357 0001 PIEZO IGNITOR 11 W080 0756 PILOT BRACKET 13 W...

Page 13: ...2 15 06 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd 29 19 12 20 5 6 19 16 4 21 18 24 1 2 3 23...

Page 14: ...System is not correctly purged purge the gas line Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and...

Page 15: ...Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is ground ing check for ground short repair ground or replace wire Remote wall switch wire is grounding Car...

Page 16: ...16 W415 0559 02 15 06 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES...