NAPOLEON products are manufactured under the strict Standard of the world recognized 

ISO 9001 : 2000 Quality Assurance Certifi cate.

NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great 
pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete fi replace is 
test-fi red and thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the 
quality product that you expect from NAPOLEON

.

NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY

The following materials and workmanship in your new NAPOLEON gas fi replace are warranted against 

defects for as long as you own the fi replace. This covers: combustion chamber, heat exchanger, stainless steel 
burner, phazer™ logs and embers, gold plated parts against tarnishing, porcelainized enamelled components 
and aluminium extrusion trims.

Electrical (110V and millivolt) components and wearable parts such as catalytic tiles, blowers, gas valves, thermal 

switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON 
will provide replacement parts free of charge during the fi rst year of the limited warranty.

 

Labour related to warranty repair is covered free of charge during the fi rst year. Repair work, however, requires 

the prior approval of an authorized company offi cial. Labour costs to the account of napoleon are based on a prede-
termined rate schedule and any repair work must be done through an authorized napoleon dealer.

CONDITIONS AND LIMITATIONS

NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (reg-

istered customer) whose name appears on the warranty registration card fi led with NAPOLEON -- provided that the purchase was made 
through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:

This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.
The gas fi replace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance 

with the installation instructions included with the product and all local and national building and fi re codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts 

installed from other manufacturers will nullify this warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and 

chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting com-
ponents used in the installation of the fi replace.

NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following condi-

tions: During the fi rst 10 years NAPOLEON will replace or repair the defective parts at our option free of charge. From 10 years to life, 
NAPOLEON will provide replacement burners at 50% of the current retail price.

In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship 

provided that the product has been operated in accordance with the operation instructions and under normal conditions.

After the fi rst year, with respect to this President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations 

with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).

After the fi rst year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation 

of a warranted part, and such expenses are not covered by this warranty.

Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty 

is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages.

This warranty defi nes the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fi replace and any other warranties 

expressed or implied with respect to this product, its components or accessories are excluded.

NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this 

product. NAPOLEON will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, 
buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or 
negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

Any damages to fi replace, combustion chamber, heat exchanger, brass trim or other component  due to water, weather damage, long 

periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your 

authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED 
TRADEMARK OF WOLF STEEL LTD.  PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.

Summary of Contents for Arlington GVFS20N

Page 1: ...1 W415 0559 02 15 06 W415 0559 02 07 06...

Page 2: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified installer service agency or the gas supplier Follow the inst...

Page 3: ...service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The heater area must be kept clear and free from combustible materials gasoline and oth...

Page 4: ...cal breakage of PHAZER logs and embers nor any venting com ponents used in the installation of the replace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for...

Page 5: ...approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product WARNING This product must be installed by a licensed plumber or gas tter when installed w...

Page 6: ...then pivoting the box open 2 Remove the 4 AA batteries and replace using the new ones 3 Pivot the box closed and re secure using the screw re moved in step 1 19 1 4 9 5 8 25 3 8 15 3 4 STOVE SHOULD NO...

Page 7: ...wire to the black wire coming from below the unit 4 Insert the clips on the blower housing into the cutouts in the rear shield Push down to lock the clips into position 5 Secure the blower using the...

Page 8: ...remove CAST FRONT INSTALLATION AND REMOVAL 3 SCREWS BRACKET FRONT 2 SCREEN INSTALLATION AND REMOVAL 1 Unscrew the four screws one in each corner from the screen 2 Remove screen from unit Follow the a...

Page 9: ...moved see Cast Front Screen Removal in the Finishing section of this manual 1 Place the rear log as shown onto the rear log support brackets Bend the bracket on the right side to help retain the rear...

Page 10: ...turn the gas control knob Never use tools If the knob will not push in and turn by hand do not try to repair it Call a quali ed service technician Force or attempted repair may result in a re or expl...

Page 11: ...om the pilot housing Blow out the housing in the same direction as the gas ow Re install the injector and the pilot tube turn on the gas and check for leaks If this does not improve the performance re...

Page 12: ...NER ORIFICE NG 7 W455 0003 54 BURNER ORIFICE LP 10 W662 0001 NG OXYGEN DEPLETION SENSOR SYSTEM 10 W662 0005 LP OXYGEN DEPLETION SENSOR SYSTEM 12 W357 0001 PIEZO IGNITOR 11 W080 0756 PILOT BRACKET 13 W...

Page 13: ...2 15 06 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd 29 19 12 20 5 6 19 16 4 21 18 24 1 2 3 23...

Page 14: ...System is not correctly purged purge the gas line Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and...

Page 15: ...Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is ground ing check for ground short repair ground or replace wire Remote wall switch wire is grounding Car...

Page 16: ...16 W415 0559 02 15 06 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES...