Page 1: ...1 W415 0559 02 15 06 W415 0559 02 07 06...

Page 2: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified installer service agency or the gas supplier Follow the inst...

Page 3: ...service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The heater area must be kept clear and free from combustible materials gasoline and oth...

Page 4: ...cal breakage of PHAZER logs and embers nor any venting com ponents used in the installation of the replace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for...

Page 5: ...approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product WARNING This product must be installed by a licensed plumber or gas tter when installed w...

Page 6: ...then pivoting the box open 2 Remove the 4 AA batteries and replace using the new ones 3 Pivot the box closed and re secure using the screw re moved in step 1 19 1 4 9 5 8 25 3 8 15 3 4 STOVE SHOULD NO...

Page 7: ...wire to the black wire coming from below the unit 4 Insert the clips on the blower housing into the cutouts in the rear shield Push down to lock the clips into position 5 Secure the blower using the...

Page 8: ...remove CAST FRONT INSTALLATION AND REMOVAL 3 SCREWS BRACKET FRONT 2 SCREEN INSTALLATION AND REMOVAL 1 Unscrew the four screws one in each corner from the screen 2 Remove screen from unit Follow the a...

Page 9: ...moved see Cast Front Screen Removal in the Finishing section of this manual 1 Place the rear log as shown onto the rear log support brackets Bend the bracket on the right side to help retain the rear...

Page 10: ...turn the gas control knob Never use tools If the knob will not push in and turn by hand do not try to repair it Call a quali ed service technician Force or attempted repair may result in a re or expl...

Page 11: ...om the pilot housing Blow out the housing in the same direction as the gas ow Re install the injector and the pilot tube turn on the gas and check for leaks If this does not improve the performance re...

Page 12: ...NER ORIFICE NG 7 W455 0003 54 BURNER ORIFICE LP 10 W662 0001 NG OXYGEN DEPLETION SENSOR SYSTEM 10 W662 0005 LP OXYGEN DEPLETION SENSOR SYSTEM 12 W357 0001 PIEZO IGNITOR 11 W080 0756 PILOT BRACKET 13 W...

Page 13: ...2 15 06 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd 29 19 12 20 5 6 19 16 4 21 18 24 1 2 3 23...

Page 14: ...System is not correctly purged purge the gas line Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and...

Page 15: ...Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is ground ing check for ground short repair ground or replace wire Remote wall switch wire is grounding Car...

Page 16: ...16 W415 0559 02 15 06 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES...