background image

StarLink

 SLE Series Alarm Communicators -- Installation Instructions 

 

and Contact ID.  In addition, the SLE Control Center gener-
ates and reports a Supervisory signal in the event that the 
network does not receive the expected supervisory test 
signal from the wireless communicator during a pre-
scheduled period.  The following models are available: 

 

SLE-GSM-3/4G 

- 2G, 3G and 4G Network Compatible 

GSM alarm capture Communicator, SIM card included.  
Black plastic enclosure.   

SLE-GSM-8D-3/4G 

- 2G, 3G and 4G Network Compatible 

GSM alarm capture Communicator. Supports remote 
downloading to the Gemini GEM-P400, GEM-P800, 
GEMP-801, Express XP-400 and XP-600 series control 
panels.  SIM card included.  Black plastic enclosure.   

SLE-CDMA 

- Universal CDMA alarm capture Communica-

tor.  Black plastic enclosure.   

SLE-CDMA-8D 

- Universal CDMA alarm capture Commu-

nicator.  Supports remote downloading to the Gemini 
GEM-P400, GEM-P800, GEMP-801, Express XP-400 
and XP-600 series control panels.  Black plastic enclo-
sure.   

 
 

ADDITIONAL COMPONENTS 

  In addition to the models listed above, the following sub-

assemblies are available: 

SLE-DLEXT

 - Optional, for up/downloading, extends dis-

tance from radio to panel, from 10 feet, up to 100 feet.  
See installation instructions WI1950.   

SLE-DLCBL

 - Download Cable, 6 feet. 

SLE-SMTCHG

 - Smart Charge Module, optional charger / 

power supply. 

SLE-ANTEXT

 - Extended antenna with 15 feet of cable. 

 
 

SPECIFICATIONS

 

 

The following specifications apply to all StarLink radio mod-
els unless otherwise stated: 

 

 

Electrical Ratings for +12V (all models powered by the 
control panel) 

 

Input Voltage:  15-10.6VDC 

 

Input Current: 65mA with peak RF transmission current of 
400mA for models SLe-GSM-3/4G and SLE-CDMA; (80mA 
with peak RF transmission current of 400mA for model SLe
-GSM-8D-3/4G and SLE-CDMA-8D) 

 

WI1936E  12/14 

333 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 

© NAPCO 2014 

INTRODUCTION 

 The 

StarLink

 alarm capture radio communicators are fully 

supervised, wireless digital two-way subscriber units sup-
ported by an extensive nationwide wireless network.  All 
models are compatible with virtually any 12VDC alarm con-
trol panel and are easy to install and test (always adhere to 
the documentation provided by the control panel manufac-
turer).  All can function as a backup to existing telephone 
lines, or as a primary communicator when telephone lines 
are absent and when connected directly to the control pan-
el Telco terminals.  When used as a backup communicator, 
all units will automatically switch the communication chan-
nel from the telephone line to the network when telephone 
line trouble is detected.   

 

  The StarLink radio communicators use proprietary data-

capture technology that captures the alarm report from the 
control panel and transmits the alarm signals to the SLE 
Control Center; the alarm signals are then forwarded to 
ANY Central Station via standard CS receiver formats 4/2 

(

 

(

 

(

 

(

 

(

 

(

 

(

 

(

 

(

 (     ) 

)

 

)

 

)

 

)

 

)

 

)

 

)

 

)

 

)

 

(1) 

(2) 

Control 
Panel 

Network  

Operator 

SLE Control Center 

(3) 

CENTRAL 

STATION 

(5) 

(4) 

RADIO REPORTING PATH 

  The diagram below shows the transmission path of a 

signal from the radio to the central station.   

 

1. 

Signal from a Control Panel.  

 

2. 

StarLink

 radio receives the signal 

transmission (from the TIP an RING wires); sends 
RF signal through the network operator.  

3. 

Network Operator

, part of the vendor system, 

a section of the cellular spectrum.   

4. 

SLE Control Center (NOC)

, receives and 

routes data. 

5. 

Central Station

StarLink 

Radio 

StarLink™ SLE Series 

Alarm Communicators  

INSTALLATION INSTRUCTIONS 

Summary of Contents for StarLink SLE Series

Page 1: ...for model SLe GSM 8D 3 4G and SLE CDMA 8D WI1936E 12 14 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs 800 645 9445 For Technical Service 800 645 9440 or visit us at http tech nap...

Page 2: ...using the Management Center screen located at www napconoc com TB6 IN 1 B F Active high input intended for wiring to the control panel bell output When this input detects a steady high it sends a bur...

Page 3: ...ommunicate 4 Blinks RF trouble antenna connection or cellu lar registration 5 Blinks Network trouble signal unable to reach the SLE Control Center 6 Blinks Unit disabled reporting or control panel dow...

Page 4: ...X5 See the section CONTROL PANEL PROGRAMMING further in this manual For Primary Mode Remove jumper 3 in jumper block labeled X5 The wir ing between the control panel and the StarLink radio is over fi...

Page 5: ...StarLink radio requires 12VDC It draws less than STARLINK RADIO RELATED EVENT REPORT CODES Contact ID by default EVENT AREA CONTACT ID PULSE 4 2 CODE ZONE IN 1 Fire 0 E110 990 1A IN 1 Burg 0 E130 991...

Page 6: ...ans missions for less than 1 second Note 80mA with peak RF transmission current of 400mA for model SLe GSM 8D 3 4G and SLE CDMA 8D Attach antenna before applying power STEP 5 SIGNAL VERIFICATION After...

Page 7: ...time the StarLink radio will check in is on April 15 not April 25 To terminate more than two conductors or conductors of different wire sizes to a terminal use the pigtail type wiring method as shown...

Page 8: ...11 9 10 2 3 4 5 1 19 18 ZONE DEDICATED TO RADIO SUPERVISION CONTROL PANEL HOUSING 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 12V PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING PANEL RING TIP 2 2K 17 16 PANEL TIP RTS R...

Page 9: ...1 19 18 CONTROL PANEL HOUSING 16VAC Refer to section SUPPLYING POWER AUX POWER RING TIP 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 12V PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING TIP 17 16 RTS R PANEL TX B PANEL RX...

Page 10: ...rrent is available HOME PHONES TO TELCO RJ31X RING TIP AUX POWER RING TIP RING TIP TELCO PHONE YELLOW BLACK Refer to section SUPPLYING POWER 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 12V PGM1 PGM2 PGM3 IN1...

Page 11: ...18 CONTROL PANEL HOUSING 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 12V PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING PANEL RING TIP 2 2K 17 16 PANEL TIP RTS R PANEL TX B PANEL RX G StarLink Radio Terminals AUX POWER...

Page 12: ...AC Refer to section SUPPLYING POWER 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 12V PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING TIP 17 16 RTS R PANEL TX B PANEL RX G CTS Y StarLink Radio Terminals PANEL RING PANEL TI...

Page 13: ...TO TELCO RJ31X TELCO T300 RJ31X RING TIP RING TIP 16VAC Transformer GRN RED YELLOW BLACK Refer to section SUPPLYING POWER 6 7 8 15 14 13 12 11 9 10 2 3 4 5 1 12V PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING TI...

Page 14: ...N3 RING PANEL RING TIP 17 16 PANEL TIP RTS R PANEL TX B PANEL RX G StarLink Radio Terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 26 27 28 29 23 24 25 33 30 31 32 Control Panel PC B...

Page 15: ...of connections RJ31X RED to StarLink module 10 RJ31X GREEN to StarLink module 11 RJ31X BROWN to Panel 32 RJ31X GRAY to Panel 33 Panel 30 to StarLink module 13 Panel 31 to StarLink module 12 GRN RED G...

Page 16: ...2 GND IN3 RING PANEL RING TIP 17 16 PANEL TIP RTS R PANEL TX B PANEL RX G StarLink Radio Terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 26 27 28 29 23 24 25 Control Panel PC Board...

Page 17: ...connections RJ31X RED to StarLink module 10 RJ31X GREEN to StarLink module 11 RJ31X BROWN to Panel 28 RJ31X GRAY to Panel 29 Panel 27 to StarLink module 12 Panel 26 to StarLink module 13 GRN BLACK RE...

Page 18: ...ion Instructions Housing Template I M P O R T A N T W HEN PRINTING OR PHOTO COPYING A TEMPLATE ALWAYS SELECT PRINTING OPTIONS TO ENSURE THAT COPIES ARE PRODUCED WITHOUT SIZE ADJUSTMENTS V ERIFY THE DI...

Page 19: ...StarLink SLE Series Alarm Communicators Installation Instructions 19 Notes...

Page 20: ...es nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for...

Reviews: