CONFIGURING THE IQ PROFILER

LED Disable Jumper
To prevent the walk test LED from turning on, remove the jumper
from the pins labeled LED DISABLE. Removing this jumper will not
affect the flashing of the LED on self test failure.

Sensitivity Setting (SEN Jumper)
The unit is shipped with no jumper in this position. This is the normal
sensitivity mode and is recommended for most installations whose
coverage area does not exceed 30’ x 35’.  Coverage out to 50’ x
50’ is possible in this mode, but the intruder will have to cover a
larger distance before detection. To have faster catch performance
this jumper must be installed. Note: Advanced signal processing
will be defeated in this high sensitivity mode. DO NOT INSTALL
THIS JUMPER IF PETS OR RODENTS ARE PRESENT.

COMPLETING THE INSTALLATION
Allow at least three minutes for the unit to stabilize after applying
power, during this time the unit will perform its own self diagnostics
and set a baseline detection level.  The LED will flash rapidly for
approximately 1 minute and not function until the unit is ready. If the
unit was installed after being kept in a hot or cold vehicle allow the
unit to operate with its cover in place for about 15 minutes. This will
insure that the unit has measured the proper room temperature.
Walk test the unit to insure the desired coverage, making any board
height adjustments that may be necessary. Note: One common
cause of short range is having the lens in up side down, always
check this! During walk test, the unit will go into a zone finding mode
for 15 seconds after each trip. This will cause the LED to light each
time a beam is entered. To view the normal detection pattern
remain motionless for at least 15 seconds between walk tests.

13

Summary of Contents for IQ PROFILER -

Page 1: ...anced Profiling Technology PASSIVE INFRARED SENSOR INSTALLATION INSTRUCTIONS Napco Security Systems Inc 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs 800 645 9445 R WI1017 08 00 1...

Page 2: ...led against Napco s proprietary built in library of false alarm signals and real alarm signals for maximum accuracy Shielded High Performance Aspheric Lenses plus Look Down Creep Zone Sensor Chamber p...

Page 3: ...y Closed Form A Relay Contact Ratings 100mA 24VDC with internal 10 Ohm current limiting resistor POWER SUPPLY REQUIREMENTS Note This unit is intended for operation from a power source that provides a...

Page 4: ...de exceptional distance profiling Far Field Lens allows for detection of large objects and ignores small targets nearby Near Field Lens allows for discrimination of small targets nearby 4 NAPCO 10 00...

Page 5: ...etection zones Sources of heat such as radiators and space heaters do not usually pose a problem as long as hot air from them does not blow directly onto the detector One exception to this is overhead...

Page 6: ...r should be off normal sensitivity NOTE Pet Immunity has not been evaluated by UL Small Pet Avoidance If you are protecting a typical room area which may include small pets or rodents no larger than 2...

Page 7: ...manner the IQ Profiler will allow a larger pet to freely move about but still retain the sensitivity required to detect an intruder The detector should be mounted at a height of 7 ft with the PC Boar...

Page 8: ...int to be used The housing provides an entry point on the top of the enclosure Any unused screw hole recess may also be used for wire entry Determine which entry is most convenient and punch out or re...

Page 9: ...the base securing the unit to the wall 3 Install circuit board and proceed with installation When installing circuit board gently push PC Board indexing tab outward to allow the board to rest on the...

Page 10: ...al the opening around the wire entry hole and any other unused holes with the supplied sealer Power Terminals 1 2 Connect 12 volt regulated or unregulated power N C Terminals 3 4 Normally closed alarm...

Page 11: ...Index On the left of the IQ Profiler circuit board is the Mounting Height Index which must be set according the parameters of the installation Adjust the Mounting Height Index by gently pushing outwa...

Page 12: ...UT TROUBLE OUTPUT IQ PROFILER CIRCUIT BOARD DETAIL Sensitivity Jumper ON High Sensitivity OFF Normal Walk Test LED PIR Sensor Tamper Switch Remove Jumper to Disable LED Look Down Lens Mounting Height...

Page 13: ...LETING THE INSTALLATION Allow at least three minutes for the unit to stabilize after applying power during this time the unit will perform its own self diagnostics and set a baseline detection level T...

Page 14: ...14...

Page 15: ...ty of merchantability must be brought within the six months following the end of the warranty period IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH O...

Page 16: ...system will in all cases provide adequate warning or protection A properly installed and maintained alarm may only reduce risk of burglary robbery fire or otherwise but it is not insurance or a guaran...

Reviews: