Keyfob Transmitters as Zone Input Devices
(Refer to display above: press the PRIOR button to go backwards).
Each of the 4 keyfob buttons can be assigned to a zone. For example, On button = point 1;
Off button = point 2; A1 = point 3; A2 = point 4. Up to 96 keyfobs (using 1 button) or 48
keyfobs (using 2 buttons) or 28 keyfobs (using all 4 buttons) or any combination up to a
maximum of 96 controlled zones can be assigned, providing multiple wireless panic buttons
on a system, each reporting to a Central Station and/or annunciating on a keypad the
keyfob zone number with a description.
To assign a keyfob to a zone:
program the keyfob
as you would a transmitter, entering the keyfob ID code, check sum and point number at
the appropriate zone. The "Quick Method" is not allowed. The zone may be hardwired to
an electrical sensor as well as assigned to a keyfob (either one will activate the zone alarm
output).
NOTE:
If assigning a keyfob to a zone, the "ON/OFF" buttons on the keyfob will no
longer arm/disarm the system. The keyfob is converted to a "panic only" device.
(Direct Entry)
DATA ENTRY AUX 1 / AUX 2 OPTIONS
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
3
Relay Group 3 Toggle
4
Relay Group 4 Toggle
5
Relay Group 5 Toggle
6
Relay Group 6 Toggle
7
Relay Group 7 Toggle
8
Relay Group 8 Toggle
9
Panic
A
Auxiliary
B
Instant
C
Burg Module PGM1 Output
Toggle
D
Access Control on Burg
Module PGM1 Output
E
Arm STAY
F
Interior Bypass
Enter Zone Descriptions
Press
1
and
2
to place the cursor; press
3
and
6
to select.
For each zone, enter a description of up to two lines. Press
U
to save each descrip-
tion.
To proceed to the next description, place the cursor under the Zone Number (e.g. "01")
and change the Zone Number using
3
and
6
.
NOTE:
Zone Descriptions can only be entered through the
GEMC-FK1 Keypad or
by using the Napco Quickloader Software.
See
Easy Menu Programming Worksheet
for available zone description characters.
Enter an identifying description for each zone. Characters are selected by pressing
keypad buttons multiple times, "Cell Phone" style. Buttons
1
through
9
plus
0
and
D
are used, as per the tables at left:
Press
R
to move cursor right.
Press
A
to move cursor left.
Notes:
1. After releasing the number button for 1 second, the character will be accepted
and the cursor advanced to the right.
2. After releasing the number button, if a new number button is pressed before
the 1 second window expires, the current character will be accepted and the
cursor automatically advanced to the right. The first of the 4 characters of this
new number button will be displayed.
3. To erase an existing entry, use
R
or
A
to move the cursor below the
character to be changed. Enter a new character to overwrite the old.
4. To generate lowercase characters, the
D
button must be pressed and
held down while pressing the number button. If the
D
button is released
during the 1 second window, the current character will change to uppercase.
Press
U
to save.
To proceed to the next description, place the cursor under the Zone Number (e.g.
“1”) and press the number that corresponds to the zone. Repeat this procedure until
all zones have been programmed. After programming the user codes, press the
NEXT
button to proceed.
001-
PRESS:
CHARACTERS
DISPLAYED
IN SEQUENCE
1
ABC1
2
DEF2
3
GHI3
4
JKL4
5
MNO5
6
PQR6
7
STU7
8
VWX8
9
YZ90
0
(SPACE) - . ( ) , / : ? #
HOLD
D
AND
PRESS:
CHARACTERS
DISPLAYED
IN SEQUENCE
1
abc1
2
def2
3
ghi3
4
jkl4
5
mno5
6
pqr6
7
stu7
8
vwx8
9
yz9
0
0
(International Characters)