NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 1
NAPCO Security Group
Programming Instructions, Volume 1
Page 23
R E - E N T E R N E W C O D E
E N T E R C O D E T O
C H A N G E ( E N T E R )
E N T E R N E W C O D E
S Y S T E M R E A D Y
1 1 / 0 1 / 1 2 1 2 : 0 9 A M
E n a b l e C h a n g e
( U s e r C o d e ) Y / N
R e i n i t i a l i z e
B S L C d e v i c e s Y / N
Status of transmitter, as follows:
NODATA
:
Transmission not yet received;
NORMAL
:
Transmitter's zone normal;
FAULT
:
Transmitter's zone open;
LOBATT
:
Transmitter battery low;
TAMPER
: Transmitter
case
open;
S.FAIL
: Supervision failure (test transmission not received within programmed
time).
ENABLE (CHANGE USER CODE):
(
Master Security Code
or
Dealer Keypad Program Code
required to view
this function
).
Allows Burg User Codes to be changed (see the section "
Security, Program
& User Codes
" for a full definition of "Burg User Code". In general, Burg User
Codes can be used to arm and disarm the Burglary system. Changing User Codes can
be performed at any GEMC-BK1 Burglary keypad; however the new User Code will
only be effective within the area assigned to the keypad that was used to change the
User Code.
Note:
The total number of Burg User Codes in a system is determined by
the number of codes added within by PCD-Windows Quickloader download software.
Change an existing Burg User Code
:
1. As detailed at the beginning of this section, press
MENU
until this "
ENABLE
(CHANGE USER CODE)
" selection appears, then press
NEXT/YES
.
2. The keypad display reads: "
ENTER CODE TO CHANGE (ENTER)
". Enter the
"old" code you want to change and press
ENTER
.
3. The keypad display reads: "
ENTER NEW CODE
". Enter the new code and press
ENTER
.
4. The keypad display reads: "
RE-ENTER NEW CODE
". To ensure the new code
entered in step 3 is correct, re-enter new code, then press
ENTER
.
Erase an existing Burg User Code
:
Burg User Codes cannot be "erased" from the system using the keypad; instead,
simply "change" the "old" code to a different code using the directions above
("
Change an existing Burg User Code
"). Using PCD-Windows Quickloader
download software, Burg User Codes can be erased using the
User Assignment
screen,
User/System Codes
tab.
Add a new Burg User Code
:
You cannot add new Burg User Codes using the GEMC-BK1 Burglary keypad.
Instead, use PCD-Windows Quickloader download software,
User Assignment
screen,
User/System Codes
tab.
REINITIALIZE BSLC DEVICES
(
Master Security Code
or
Dealer Keypad Program Code
required to view this
function
). This menu item is typically used when replacing a Burglary SLC device. This
selection is intended to ensure valid communication and correct operation for each
Burglary SLC device in the system.
When initiated, power is removed from the GEMC-BSLC bus (the common pathway
that connects all of the Burglary SLC devices), then power to the GEMC-BSLC bus
is restored. Each device's pre-existing configuration (stored within each device) is
retained. To ensure each device's ability to respond to the Burglary SLC circuit
board, each Burglary SLC device "type" is retrieved from each device by the GEMC-
BSLC circuit board (this process takes about 20 seconds, depending on the number
of devices). The retrieval of each SLC device "type" indicates each device's ability
to respond to the Burglary SLC circuit board; for each successful retrieval, the
GEMC-BSLC instructs each device to use its pre-existing configuration.
A full Burglary SLC device initialization is also available in PCD-Windows Quick-
loader download software. In the PCD-Windows Quickloader toolbar, click
Panel
FUNCTION MENU -- BURGLARY KEYPAD (CONT'D)
CHANGING USER CODES