X
GEM-X255 Programming Instructions
L
NAPCO Security Systems
WI1092B 9/02
!
Page 48
RF RECEIVERS & SUPERVISORY TIMER OPTIONS
(ADDRESS 3776 & 3760-3775)
Default for Number of Receivers
depends on Easy Menu Question for
RF Transmitters.
ADDRESS 3776
LEFT
RIGHT
blank (•)
Number of RF
Receivers
DATA
ENTRIES
RIGHT
blank (•)
1
2
3
4
RF Receiver(s)
None
1
2
3
4
RF RECEIVERS:
Up to 4 RF Receivers may be programmed.
NOTE:
This adds wireless capability to the system, increasing
up to 255 the number of zones.
!
1. Select the number of receivers from the table shown.
!
2. Enter in corresponding right digit address location shown
(left digit is not used).
[Default = blank (•) blank (•) from address 3760-3767]
ADDRESS
3760-3767
LEFT
ADDR
RIGHT
3760
3761
3762
3763
3764
3765
3766
3767
RF SUPERVISORY
TIMER
RF TRANSMITTER
Type 0
Window/Door, 2 Pt.
Type 1
Window/Door, 2 Pt.
Type 2
Window/Door, 2 Pt.
Type 3
Window/Door, 2 Pt.
Type 4
Window/Door, 4 Pt.
Type 5
PIR
Type 6
PIR
Type 7
Smoke Detector
[Default = blank (•) blank (•) from address 3768-3775]
ADDRESS
3768-3775
LEFT
ADDR
RIGHT
3768
3769
3770
3771
3772
3773
3774
3775
RF SUPERVISORY
TIMER
RF TRANSMITTER
Type 8
Smoke Detector
Type 9
Keyfob
Type A
Dual Tech.
Type B
Keyfob
Type C
Window/Door, 4 Pt.
Type D
PIR
Type E
Smoke Detector
Type F
Napco Glass Break
DATA ENTRIES
LEFT
RIGHT
blank (•) blank (•)
blank (•)
1
blank (•)
2
blank (•)
3
blank (•)
4
blank (•)
5
blank (•)
6
blank (•)
7
blank (•)
8
blank (•)
9
blank (•)
0
blank (•)
B
blank (•)
C
blank (•)
D
blank (•)
E
blank (•)
F
1
blank (•)
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
0
1
B
1
C
1
D
1
E
1
F
2
blank (•)
2
1
2
2
2
3
2
4
2
5
DELAY
0 min.
30 min.
60 min.
90 min.
120 min.
150 min.
180 min.
210 min.
240 min.
270 min.
300 min.
330 min.
360 min.
390 min.
420 min.
450 min.
480 min.
510 min.
540 min.
570 min.
600 min.
630 min.
660 min.
690 min.
720 min.
750 min.
780 min.
810 min.
840 min.
870 min.
900 min.
930 min.
960 min.
990 min.
1020 min.
1050 min.
1080 min.
1110 min.
RF SUPERVISORY TIMERS
DATA ENTRIES
LEFT
RIGHT
2
6
2
7
2
8
2
9
2
0
2
B
2
C
2
D
2
E
2
F
3
blank (•)
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
3
0
3
B
3
C
3
D
3
E
3
F
4
blank (•)
4
1
4
2
4
3
4
4
4
5
4
6
F
F
DELAY
1140 min.
1170 min.
1200 min.
1230 min.
1260 min.
1290 min.
1320 min.
1350 min.
1380 min.
1410 min.
1440 min.
1470 min.
1500 min.
1530 min.
1560 min.
1590 min.
1620 min.
1650 min.
1680 min.
1710 min.
1740 min.
1770 min.
1800 min.
1830 min.
1860 min.
1890 min.
1920 min.
1950 min.
1980 min.
2010 min.
2040 min.
2070 min.
2100 min.
7650 min. = 127
Hr., 30 min.
RF SUPERVISORY TIMERS
RF SUPERVISORY TIMERS:
RF Supervisory Timers may be
programmed for each type of transmitter used. A transmitter will send a
transmission every time it is tripped, when there is NO activity, the
transmitter sends a status transmission about once an hour. If the
receiver does NOT receive ANY signal (a trip or a status) from a
transmitter in the time specified for transmitter type, a system trouble “
RF
SUPERVISORY FAILURE
” will be displayed at the keypad.
!
1. Select timer delay from the table shown. Timers are programmed
in increments of 30 minutes each. Valid entries are 03-FF, 90
minutes-7650 min (127 hr,30 min).
WARNING:
Timers have uncertainty of +/-30 minutes. Do not
use entries 0-2 (shaded areas).
!
2. Enter in corresponding address locations above (left and right
digits).
!
3. For a desired
timer not
listed do the following:
A. Choose a desired timer (intervals of 30),
ex: 3000 min. (50 Hours)
B. Divide it by 30, ex: 3000/30 = 100
C. Divide it by 16
6 Quotient Left Digit
16 100
96
4 Remainder Right Digit
NOTE:
These timers apply only to Supervised RF Transmitters (see
RF Transmitters in Easy Menu Driven Mode Programming).
RF Rece
ive
rs & Supe
rvi
sor
y Ti
me
r Options