background image

INSTALLATION 

INSTRUCTIONS 

HARDWIRE 

WIRELESS 

G E M - X 2 5 5  

CONTROL PANEL/COMMUNICATOR 

WI1093C  3/04 

© Napco 2004 

R

For use with "Classic" keypad 

GEM-RP1CAe2

 and with "K Series" keypad 

GEM-K1CA

 

"K Series" GEM-K1CA  

G E M I N I  

SYSTEM READY 
01/01/03   12:00 AM 

ARM

ED

 

C OMPUTER IZED SE CUR ITY  SYS TE M  

STA

TUS

 

R

   

1

   

2

   

3  

 

B

   

4

   

5

   

6  

 

C

   

7

   

8

   

9

  

0

 

U

 

NEXT/YES 

PRIOR/NO

 

AREA 

G

 

"Classic" GEM-RP1CAe2  

G E M I N I  

SYSTEM READY 
01/01/03   12:00 AM 

ARM

ED

 

C OMPUTER IZED SE CUR ITY  SYS TE M  

STA

TUS

 

A

   

1

   

2

   

3  

 

B

   

4

   

5

   

6  

 

C

   

7

   

8

   

9

  

0

 

D

 

NEXT/YES 

PRIOR/NO

 

AREA 

G

 

Summary of Contents for Gemini GEM-X255

Page 1: ...d with K Series keypad GEM K1CA K Series GEM K1CA G E M I N I SYSTEM READY 01 01 03 12 00 AM ARMED COMPUTERIZED SECURITY SYSTEM STATUS R 1 2 3 B 4 5 6 C 7 8 9 0 U NEXT YES P PRIOR NO Q AREA G Classic...

Page 2: ...ting of alarms over a TCP IP based Intranet or Internet net work Page 30 new Keypad messages System Troubles added to accommodate the new ACM and NetLink systems THIS MANUAL INCLUDES FEATURES WHICH AR...

Page 3: ...ton operate identically in Program Mode for both keypads The D button and the U button operate identically in Program Mode for both keypads The button and the button operate identically in Program Mod...

Page 4: ...ation 16 4 Wire Smoke Detectors 17 2 Wire Smoke Detectors 17 Telephone Lines 18 KEYPAD CONFIGURATION MODE 19 Keypad Installation 19 Configuring the Keypads 19 BASIC OPERATION 22 User Codes Zone Descri...

Page 5: ...ible computer with NAPCO s PCD Windows Quickloader software and PCI2000 computer interface Or the panel may be programmed using the keypad in its secondary mode of operation In keypad programming mode...

Page 6: ...m 2 SIA 4 3 1 4 2 Express and Point ID Rotary dial TouchToneTM only and TouchToneTM with Rotary backup Three 20 digit telephone numbers Backup Reporting Double Reporting Split Reporting 195 User Codes...

Page 7: ...t including PGM output PGM Output 5mA 12V Special Application Keypad Current GEM RP1CAe2 GEM K1CA 100mA 35mA if backlighting is disabled cut W1 W2 W3 PGM Output 5mA 12V Special Application Maximum Num...

Page 8: ...1000 Relay Board single output RBAT4 Rechargeable Battery 12VDC 4AH RBAT6 Rechargeable Battery 12VDC 6AH RBAT7 Rechargeable Battery 12 VDC 7AH RBATH1 Dual Battery Harness RM3008 Relay Module in enclos...

Page 9: ...riority Do not program any zones for Keyswitch Arming System must be serviced at least once every year Residential Fire and Combination Residential Fire Burglary must program Residential Fire Keypad E...

Page 10: ...for the machine screws it may be discarded after use Keypad A keypad should be located near each exit entry door The keypad features a handy pull up reference label Before mounting the keypad onto th...

Page 11: ...her than those required such as the dining room bed rooms utility room furnace room and hallways Heat detectors rather than smoke detectors are recommended in kitchens at tics and garages due to condi...

Page 12: ...acing to the Ademco 7720 Long Range Wireless System The RM3008 may be used to interface the GEM X255M control panel to the Ademco 7720 transmitter in order to meet UL Central Station Grade A or Grade...

Page 13: ...mitter to be tested by faulting the zone The transmitter signal strength can be displayed using the DISPLAY RF XMITTER STAT function Enter a Level 3 User Code or enter the Dealer Code press the A butt...

Page 14: ...1 2 BATTERY The RED and BLACK flying leads must be connected to a 12VDC 4 6 or 7 AH Rechargeable Battery to serve as backup power in the event of AC Power Failure NOTE To calculate the available stan...

Page 15: ...cable run from the panel to the farthest keypad daisy chained or home run is less than 1000 feet The maximum distance for seven keypads is 300 feet using 22 AWG wire NOTE When running keypad wire avoi...

Page 16: ...nnect the device controlled by the programmable output between terminal 15 and terminal 14 15 RESET OUTPUT EXPANDED ZONE CONFIGURATION The GEM X255 Control Panel may be expanded up to 255 zones This m...

Page 17: ...cation is de sired to reset the smoke detectors select this option for the desired fire zone Do not use in UL installations See page 9 NOTE Do not program Fire Alarm Verification in California 2 W IR...

Page 18: ...RATION Where more than two 2 wire smoke detector zones are required select any of Zones 1 6 for 2 wire fire as follows 1 Program the selected zone s 1 6 for 2 Wire Smoke Detectors and Fire 2 Cut the l...

Page 19: ...he GEM RP1CAe2 GEM K1CA Configuration Mode 1 Move jumper JP1 located at the upper center of the control panel board from Pins 1 2 top two to Pins 2 3 bottom two NOTE See the Wiring Diagram 2 After abo...

Page 20: ...r see Keypad Programming Workbook similar to its keypad address If no other EZMs are to be used designate the keypad as Group 01 at the EZM ADDRESS 00 display In multiple EZM systems enter an assigned...

Page 21: ...NAPCO Security Systems Inc 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs call toll free 800 645 9445 For direct line to Technical Service call toll free 800 645 9440 Internet http...

Page 22: ...that is easily activated when needed and dormant at other times Intended for the occasional or temporary user repairman etc who would otherwise be denied access to the premises It may then be used to...

Page 23: ...er to the user to return to the keypad and disarm 2 GEM RP1CAe2 GEM K1CA keypads only An S in the display e g EXIT TIME XXX S will appear as a re minder that the system is being armed with the Service...

Page 24: ...can press the R or A button until TO DE LAY AUTO ARM PRESS 1 4 N is displayed Enter the number of hours to delay arming followed by the U or D button If DELAY AUTO ARM Y N is displayed press the NEXT...

Page 25: ...the zone number The zone will be unbypassed the next time the system is disarmed Security Bypass Zones programmed for Selective Bypass may be removed from the system prior to arming as follows 1 Ente...

Page 26: ...r s authority level will be suppressed and will not display 2 Press the PRIOR NO button to skip a function press the NEXT YES button to execute it DISPLAY ZN FAULTS Press the YES button to identify al...

Page 27: ...then disarm GUARD TOUR ON OFF A Guard Tour schedule is programmable through Napco s PCD Windows Quickloader software Guard Tour is toggled on and off by pressing P When Guard Tour is toggled on the pr...

Page 28: ...s events scroll back using the PRIOR button DISPLAY FIRE LOG Displays most recent fire events Line 1 displays event and date Line 2 displays time area and zone To check previous fire events scroll bac...

Page 29: ...the YES button to check the status of up to 255 transmitters The keypad will display zone number Z01 Z96 transmitter ID code number 6 digits point number PT1 PT4 9 for unsupervised status of transmit...

Page 30: ...EYPAD ACM TAMPER Keypad or ACM cover opened NNN is keypad number address E12 NN BURG EZM TRBL Expansion zone module failure NN module number E13 NN BURG EZM TAMPER EZM module cover re moved NN module...

Page 31: ...lid time to be entered into the Aux Output Access Control in the Time Selection Screen If Access Control on Aux Output is selected entering the Access Code see User Code Programming in Easy Menu Drive...

Page 32: ...the system The Ambush Zone will automatically report when programmed to report an alarm Ambush Type 1 a 2 digit prefix code this type must not be used in a SIA CP 01 compliant system Enable as follows...

Page 33: ...on schedule and a rearm delay is programmed see Time Selection the panel will automatically rearm after the delay if no activity has been detected Auto Output Test Upon Arming Required for UL Mercant...

Page 34: ...ing machine The answering machine will pick up on its programmed number of rings as usual Note The number of rings programmed into the panel must exceed that of the answering machine Disable Answering...

Page 35: ...me transmission would occur for Zone 15 25 35 etc Cold Start Caution Erases the entire program codes schedules etc leaving the panel as it came right out of the box Access Location 4093 then press the...

Page 36: ...adionics Fast Radionics BFSK Universal High Speed Radionics Modem 2 Osborne Hoffman Quickalert Formats Ademco Slow Silent Knight Slow Silent Knight Fast Sescoa Vertex DCI Franklin Slow Franklin Fast S...

Page 37: ...n this case the report code received is not indicative of a system trouble but is an indication of a successful transmission Should the transmis sion fail the keypad will display E03 00 COMM FAIL This...

Page 38: ...ay E Lugs E3 E4 E5 E7 E9 E10 E14 E18 E19 E22 E9 See Fire Lug E10 See Burglary Lug E19 See Veri Phone Silence All Outputs During Audio Session E22 Common terminal for Reset Relay Use Napco Part No WL1...

Page 39: ...el to monitor the phone line A failure will display as E08 00 TELCO LINE1 FAIL Program this system trouble to activate the Burglary Output If a time is entered in Telco Line Test Delay the line will b...

Page 40: ...A fire condition that has not been restored will cause the zone number and description to scroll To reset acknowledge the con dition enter a valid code then press the C button If Keypad Fire is progr...

Page 41: ...hpad backlighting W2 Cut to disable LCD backlighting Key Fob Transmitters AuxOut Chirp on Key Fob Arm Disarm Select Bus Output for Key Fob Chirp Disable Aux Out Clear on Disarm AuxOut Chirp on Key Fob...

Page 42: ...n a system where openings are on 24 hour protection zones and access is only allowed if the zone is Bypassed by an authorized User and then Unbypassed when done A typical application would be a wareho...

Page 43: ...e Direct Address Program Mode Advance to the PROG screen then change the 6 digit code as required The Download Security Code is the six digit code required to establish connection to the PCD Windows S...

Page 44: ...ore dialing rather than look for a nonstandard dial tone Contact the telephone equipment supplier to find out how long a delay is required before dialing Select Pre Dial Delay by pro gramming one D fo...

Page 45: ...ne Remote Panic See Panic Zone Report Digital Dialer Exit Error Recent Closing A Recent Closing transmission is sent if an alarm occurs within two 2 minutes after the expiration of the Exit Time If th...

Page 46: ...in the programmed Sensor Watch time a system trouble will result and E22 NN PIR SENSOR TRBL will be displayed at the key pad where NN are the zone number s Select the RESET SENSOR MSG function to rese...

Page 47: ...ter Ringback When a closing report is successfully received the central station will acknowledge by returning a kissoff signal When the kis soff is received by the communicator a 2 second ringback ton...

Page 48: ...anel leaves the factory with no zones programmed for Auto Reset If Enable CP 01 Features is selected in the Easy Programming menu all non fire zones will not be programmed for Auto Reset System Troubl...

Page 49: ...is programmed for Double or Split Reporting Private telephone systems may require a Dial Tone Detection E or Pre Dial Delay D followed by an access number to obtain an outside line See Access Number f...

Page 50: ...if both are selected Note that if Backup Reporting is also selected the communicator will alternate between TouchTone and rotary dial to reach Telephone 1 then Telephone 2 See Backup Report on Telco...

Page 51: ...rammable each with its dedicated Authority Level and Access Byte The Authority Level comprises an Option Code Refer to Programming Manual WI1092 for descriptions of levels and options If reporting to...

Page 52: ...tire Group If Enable Local Alarm on First ZoneAND Trip Address 2419 is programmed a trip on any Zone of the Group will cause an alarm output and alarm display at the keypad there will be no communicat...

Page 53: ...mum required capacity 1 STANDBY CURRENT STANDBY CURRENT Amps DEVICE QTY EACH TOTAL GEM X255 1 X 0 120 GEM EZM4 8 X 0 050 GEM EZM8 X 0 050 GEM RP1CAe2 GEM K1CA X 0 100 GEM RP1CAe2 GEM K1CA 1 X 0 035 RM...

Page 54: ...cessary use this wiring legend to relocate wire leads to their proper terminals Enter wire identification number or color code in WIRE NUMBER column and enter wire function in DESCRIPTION col umn opti...

Page 55: ...DOWNLOAD 3 DISPLAY RF XMITTER STAT 3 N RELAY CONTROL 1 2 3 O USER MODE NOTES A Displays only with faulted Zones present B Displays only with bypassed Zones present C Displays only with Help Phones in...

Page 56: ...EST DISPLAY PHONE S DISPLAY SYS TRBL DISPLAY FIRE ALARM DISPLAY FIRE TRBL DISPLAY OP CL ACTIVATE OVERVIEW ACTIVATE CHIME ACTIVATE WATCH ACTIVATE GUARD TOUR RESET SYSTEM TRBL RESET SENSOR MSG START EXI...

Page 57: ...S ENTER ZONE 00 E AUX OUTPUT ZONES ENTER ZONE 00 E SENSOR WATCH ZNS ENTER ZONE 00 E KP SNDR ALRM ZNS ENTER ZONE 00 E AUTO BYP RENT ZN ENTER ZONE 00 E ENABLE NO EOLR ZONES Y N E ENABLE TELCO LINE TEST...

Page 58: ...X GEM X255 Installation Instructions L NAPCO Security Systems WI1093C 3 04 Page 58 NOTES...

Page 59: ...ins 1 2 SYSTEM READY Move Jumper JP5 from Pins 1 2 to Pins 2 3 Wait about 15 seconds 01 OUT OF SYSTEM JP5 is located at the top right corner of the circuit board If a Compatibility Number other than 0...

Page 60: ...X GEM X255 Installation Instructions L NAPCO Security Systems WI1093C 3 04 Page 60 GEM X255 WIRING DIAGRAM...

Page 61: ...minimum default is 30 seconds If an attempt is made to change the Entry Delay time to less than 30 seconds the time will be entered as 30 seconds The maximum programmable time is 255 seconds The pane...

Page 62: ...lt Find can not be initiated from an armed panel and all digital dialer reporting in same area is inhibited while in Fault Find Fault Find Central Station Reporting Code is located at address 0887 Key...

Page 63: ...bled 4 All zones are programmed with report codes and as burg fire alarm types depending on whether they were selected as fire zones Zones not selected as fire are burg type 5 The reporting format is...

Page 64: ...onnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are con...

Page 65: ...ssary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commiss...

Page 66: ...X GEM X255 Installation Instructions L NAPCO Security Systems WI1093C 3 04 Page 66 Notes...

Page 67: ...L NAPCO Security Systems X GEM X255 Installation Instructions WI1093C 3 04 Page 67 Notes...

Page 68: ...her assumes nor au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be...

Reviews: