GEM-P1664EX Programming Instructions
Page 47
WI1387 7/05
ZONE OPTIONS - ZONES 33 TO 48 (ADDRESS 1157-1272)
Di
rec
t A
d
dre
ss
P
rogr
am Mode
ZONE OPTIONS
ZONES 45-48
LEFT DATA VALUES
(CIRCLE
)
ADDRESS
ZONES 41-44
RIGHT DATA VALUES
(CIRCLE
)
ZONES 37-40
LEFT DATA VALUES
(CIRCLE
)
ADDRESS
ZONES 33-36
RIGHT DATA VALUES
(CIRCLE
)
ZN48 ZN47 ZN46 ZN45 L ADDR R ZN44 ZN43 ZN42 ZN41 ZN40 ZN39 ZN38 ZN37 L ADDR R ZN36 ZN35 ZN34 ZN33
50ms Loop Response
(A)
8
4
2
1
8
4
2
1
8
4
2
1
8
4
2
1
Priority
8
4
2
1
1221
8
4
2
1
8
4
2
1
1157
8
4
2
1
Priority with Bypass
8
4
2
1
1222
8
4
2
1
8
4
2
1
1158
8
4
2
1
Auto-Bypass
8
4
2
1
1223
8
4
2
1
8
4
2
1
1159
8
4
2
1
Selective Bypass
8
4
2
1
1224
8
4
2
1
8
4
2
1
1160
8
4
2
1
Keyswitch Arming
8
4
2
1
1225
8
4
2
1
8
4
2
1
1161
8
4
2
1
Auto-Bypass Re-entry
8
4
2
1
1226
8
4
2
1
8
4
2
1
1162
8
4
2
1
Pre-Alarm Warning
8
4
2
1
1227
8
4
2
1
8
4
2
1
1163
8
4
2
1
Never Arm
8
4
2
1
1228
8
4
2
1
8
4
2
1
1164
8
4
2
1
24-Hour Zone
8
4
2
1
1229
8
4
2
1
8
4
2
1
1165
8
4
2
1
Alarm Output
8
4
2
1
1230
8
4
2
1
8
4
2
1
1166
8
4
2
1
Pulsed Alarm Output
8
4
2
1
1231
8
4
2
1
8
4
2
1
1167
8
4
2
1
PGM1 Output
8
4
2
1
1232
8
4
2
1
8
4
2
1
1168
8
4
2
1
PGM2 Output
8
4
2
1
1233
8
4
2
1
8
4
2
1
1169
8
4
2
1
Entry/Exit 1
8
4
2
1
1234
8
4
2
1
8
4
2
1
1170
8
4
2
1
Entry/Exit 2
8
4
2
1
1235
8
4
2
1
8
4
2
1
1171
8
4
2
1
Exit/Entry Follower
8
4
2
1
1236
8
4
2
1
8
4
2
1
1172
8
4
2
1
Auto Reset
8
4
2
1
1237
8
4
2
1
8
4
2
1
1173
8
4
2
1
Swinger Shutdown
8
4
2
1
1238
8
4
2
1
8
4
2
1
1174
8
4
2
1
Chime
8
4
2
1
1239
8
4
2
1
8
4
2
1
1175
8
4
2
1
Abort Delay
8
4
2
1
1240
8
4
2
1
8
4
2
1
1176
8
4
2
1
Power-up Delay
8
4
2
1
1241
8
4
2
1
8
4
2
1
1177
8
4
2
1
Day Zone Open
8
4
2
1
1242
8
4
2
1
8
4
2
1
1178
8
4
2
1
Day Zone Short
8
4
2
1
1243
8
4
2
1
8
4
2
1
1179
8
4
2
1
Alarm on Day Zone
8
4
2
1
1244
8
4
2
1
8
4
2
1
1180
8
4
2
1
Alarm Telco 1
8
4
2
1
1245
8
4
2
1
8
4
2
1
1181
8
4
2
1
Alarm Restore 1
8
4
2
1
1246
8
4
2
1
8
4
2
1
1182
8
4
2
1
Trouble Telco 1
8
4
2
1
1247
8
4
2
1
8
4
2
1
1183
8
4
2
1
Trouble Restore 1
8
4
2
1
1248
8
4
2
1
8
4
2
1
1184
8
4
2
1
Alarm Telco 3
8
4
2
1
1249
8
4
2
1
8
4
2
1
1185
8
4
2
1
Alarm Restore 3
8
4
2
1
1250
8
4
2
1
8
4
2
1
1186
8
4
2
1
Trouble Telco 3
8
4
2
1
1251
8
4
2
1
8
4
2
1
1187
8
4
2
1
Trouble Restore 3
8
4
2
1
1252
8
4
2
1
8
4
2
1
1188
8
4
2
1
No EOL Resistor
8
4
2
1
1253
8
4
2
1
8
4
2
1
1189
8
4
2
1
Trouble on Open
8
4
2
1
1254
8
4
2
1
8
4
2
1
1190
8
4
2
1
Trouble on Short
8
4
2
1
1255
8
4
2
1
8
4
2
1
1191
8
4
2
1
Zone Area 1
8
4
2
1
1256
8
4
2
1
8
4
2
1
1192
8
4
2
1
Zone Area 2
8
4
2
1
1257
8
4
2
1
8
4
2
1
1193
8
4
2
1
Interior (Stay) Bypass
8
4
2
1
1260
8
4
2
1
8
4
2
1
1196
8
4
2
1
Keypad Sounder on Alarm
8
4
2
1
1261
8
4
2
1
8
4
2
1
1197
8
4
2
1
2-Wire Smoke Detectors
(B)
8
4
2
1
(•) 1262 (•)
8
4
2
1
8 4
2
1
1198 (•)
8
4
2
1
Fire (C)
8
4
2
1
1263
8
4
2
1
8
4
2
1
1199
8
4
2
1
Fire Alarm Verification
(C)
8
4
2
1
1264
8
4
2
1
8
4
2
1
1200
8
4
2
1
RESERVED
8
4
2
1
(•) 1265 (•)
8
4
2
1
8
4
2
1
(•) 1201 (•)
8
4
2
1
Zone ANDing Group 1
8
4
2
1
1266
8
4
2
1
8
4
2
1
1202
8
4
2
1
Zone ANDing Group 2
8
4
2
1
1267
8
4
2
1
8
4
2
1
1203
8
4
2
1
Zone ANDing Group 3
8
4
2
1
1268
8
4
2
1
8
4
2
1
1204
8
4
2
1
Zone ANDing Group 4
8
4
2
1
1269
8
4
2
1
8
4
2
1
1205
8
4
2
1
Sensor Watch
8
4
2
1
1270
8
4
2
1
8
4
2
1
1206
8
4
2
1
RESERVED
8
4
2
1
1271
8
4
2
1
8
4
2
1
1207
8
4
2
1
Chime 2
8
4
2
1
1272
8
4
2
1
8
4
2
1
1208
8
4
2
1
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
Zone Area 3
8
4
2
1
1258
8
4
2
1
8
4
2
1
1194
8
4
2
1
Zone Area 4
8
4
2
1
1259
8
4
2
1
8
4
2
1
1195
8
4
2
1
1.
Select
the desired zone option.
s
ZONE OPTIONS
50ms Loop Response
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
3.
Search table
below for data entry.
4.
Enter data
in address locations (left and right
digits). Press [Enter] or [ON/OFF] to save.
L
ADDR
R
blank (•) 0490
1
ADDRESS LOCATION
NOTE:
Dark shaded boxes = option not available.
See Direct Address Programming Example page 22.
4
8
2 1
DIGIT VALUE DATA ENTRY
Blank (
.
)
4
8
2 1
1
4
8
2 1
2
8
1
2
4
3
4
8
2 1
4
5
4
8
2 1
4
8
2 1
6
4
8
2 1
7
4 2 1
DIGIT VALUE DATA ENTRY
8
4 2 1
9
4 2 1
0
1
2
4
B
4 2 1
C
D
4 2 1
4 2 1
E
4 2 1
F
8
8
8
8
8
8
8
8
For notes (A), (B) and (C), see next page.
2.
Enable
desired options for each zone
by drawing a circle around its
corresponding binary data value.
NOTE:
No circle = feature disabled.