![NAPCO Gemini GEM-P1664EX Programming Instructions Manual Download Page 37](http://html1.mh-extra.com/html/napco/gemini-gem-p1664ex/gemini-gem-p1664ex_programming-instructions-manual_705496037.webp)
L
NAPCO Security Systems
X
GEM-P1664EX Programming Instructions
Page 37
WI1387 7/05
Di
rec
t A
d
dre
ss
P
rogr
am Mode
EZM GROUP OPTIONS (ADDRESS 1455-1468)
EZM Group 1
LEFT
RIGHT
blank
ADDRESS 1455
EZM Group 2
LEFT
RIGHT
blank
ADDRESS 1456
EZM Group 3
LEFT
RIGHT
blank
ADDRESS 1457
EZM Group 4
LEFT
RIGHT
blank
ADDRESS 1458
EZM Group 5
LEFT
RIGHT
blank
ADDRESS 1459
EZM Group 6
LEFT
RIGHT
blank
ADDRESS 1460
EZM Group 7
LEFT
RIGHT
blank
ADDRESS 1461
EZM Group 8
LEFT
RIGHT
blank
ADDRESS 1462
EZM Group 9
LEFT
RIGHT
blank
ADDRESS 1463
EZM Group 10
LEFT
RIGHT
blank
ADDRESS 1464
EZM Group 11
LEFT
RIGHT
blank
ADDRESS 1465
EZM Group 12
LEFT
RIGHT
blank
ADDRESS 1466
EZM Group 13
LEFT
RIGHT
blank
ADDRESS 1467
EZM Group 14
LEFT
RIGHT
blank
ADDRESS 1468
Default depends on Easy Menu Question “
# OF ZNS IN AREA 1 ENTER # ZONES
” and “
EZ ZONE DOUBLING? Y/N
”. For example, if
64 Zones are used and Zone Doubling is
not
enabled, then all 14 Groups will be automatically enabled. If 64 Zones are
used and Zone Doubling is enabled, then only Groups 1-12 will be automatically enabled.
NOTE:
If “Zone Doubling” (Address 1423, option 1) is
not
enabled, then Zones 1-8 are included in the control panel
and Zones 9-64 (Groups 1-14) are EZM Zones. If “Zone Doubling” is enabled, then Zones 1-16 are included in the
control panel and Zones 17-64 (Groups 1-12) are EZM Zones (and Groups 13 and 14 must not be used).
EZM GROUP OPTIONS:
Up to 14 Groups of 4 Zones each may be pro-
grammed depending on the number of Zones used and which EZM mod-
ules are connected. Each Group represents 4 Zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations
above.
NOTE:
Dark shaded data value box shows option not available.
3. Press
U
or
D
to save.
EZM TYPE
DATA
ENTRIES
OPTION
blank (•)
Not used
(No EZM
present)
1
4-Zone EZM
EZM
GROUP
NORMAL
DOUBLED
1
9-12
17-20
2
13-16
21-24
3
17-20
25-28
4
21-24
29-32
5
25-28
33-36
6
29-32
37-40
7
33-36
41-44
8
37-40
45-48
9
41-44
49-52
10
45-48
53-56
11
49-52
57-60
12
53-56
61-64
13
57-60
14
61-64
ZONES COVERED