S Y S T E M   T R O U B L E   E R R O R   C O D E S  

Your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a problem 
should occur, the SYS TBL (system trouble) light will display in the keypad window along with one or more of the following error codes. 
If the problem is related to a specific zone or device, the corresponding number will also be indicated. Below is a list of the most 
common troubles along with the necessary corrective action, if any. If a message appears that is not listed below, call your security 
professional for service. When a system trouble occurs, the keypad can be silenced and the display can be cleared by pressing 

C

. The system can then be armed and disarmed as usual. 

Note:

 If you cannot clear a system  trouble yourself, call installing company for service as soon as possible. 

Trouble  

Indication 

System Trouble 

Condition 

Action 

 

E-01 

AC Power Failure 

This trouble will occur if AC power is not present. Make sure system transformer is plugged into AC 
receptacle and check the circuit breaker, otherwise call installing company for service. 

 
E-02 

Low Battery 

If there has been a recent power failure, the battery may be partially depleted and must be recharged 
by the control panel. The control panel performs an automatic test of the battery every 24 hours, at 
which time the trouble will clear if the battery has been recharged. 
 
If the trouble does not go away in 24 hours, call installing company for service. 

 
E-03 

Communication  
Failure 

The system was not able to report to central station. If this is due to a temporary interruption in the 
telephone service, the trouble can be cleared when the service is restored by performing a 
Communication Test:   
 

1.

While disarmed, enter your User Code followed by 

R

2.

Answer NO (press 

Q

) until “15” (Telephone Test) appears in the window. 

3.

Press YES (

P

) to send a test signal to the central station. 

4.

If the trouble continues,  call installing company for service. 

Summary of Contents for Gemini GEM-K3DGTL

Page 1: ...M K3DGTL KEYPAD NAPCO 2006 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 P Q G U NEXT Y...

Page 2: ...ion and state of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests Note The K Series GEM K3DGTL keypad is c...

Page 3: ...S 21 PROGRAMMING USER CODES 22 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 27 TROUBLESHOOTING 31 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL __________________ CENTRAL STATION ________...

Page 4: ...TORS 1 2 3 4 5 6 7 12 8 9 10 11 13 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 INTERIOR BYPASS FIRE TBL SYS TBL CHIME 9...

Page 5: ...splays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ENTER Button Entry key Causes the entered code or selected function to be executed ST...

Page 6: ...eave the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the system with a faulted Zone a 3 second tone will sound at the keypad and P will disp...

Page 7: ...d while others remain disarmed Manager s Mode The Manager s Mode allows the user to arm disarm other areas in a partitioned system To arm a different area 1 Press the numerical key representing the ot...

Page 8: ...rotection When retiring for the evening after all family members are home you can cancel the entry delay on the Entry Zone s To arm with instant protection press and hold P for 2 seconds after arming...

Page 9: ...n of a police emergency Police Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows a user to exit the premises wh...

Page 10: ...call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press U After the system is disarmed the window will continue to display the number s of the zone s violated...

Page 11: ...ition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds Fire Zone Trouble The system is constantly monitoring the Fire...

Page 12: ...with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not s...

Page 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Page 15: ...rmal operating mode if no activity is detected for longer than one minute 1 Display Zone Status Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on...

Page 16: ...l sound a tone at the keypad when the programmed zone is opened while disarmed To deactivate the Chime Mode execute Function 7 once again Note The Chime Mode is disabled while armed 8 Activate Watch M...

Page 17: ...reset press C to clear the display enter the Function Menu scroll to Reset Sensor Watch Failure and press U If you cannot correct the problem call for service 11 Start Exit Time Optional Start Exit T...

Page 18: ...hours To Delay Arm the system With Function 16 in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by U At the end of this 1 4 hour Delay Arming period the siren will sound...

Page 19: ...press NEXT P to proceed to the next group or PRIOR Q to scroll back to the previous group Press C when done Relay Group 01 ____________________________________ Relay Group 02 ________________________...

Page 20: ...lled during the Abort De lay or cancelled after the report is sent and an acknowledgement of the can cellation is received a C will appear in the keypad window Regular Burglary Non 24 Hour Zone report...

Page 21: ...all for service Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was...

Page 22: ...ming Reprogramming a User Code 1 Press R followed by the the 2 digits of the user number to be programmed Example for User 4 enter 04 2 Press R followed by the new User Code Note User Codes may be up...

Page 23: ...code 5 Press C to exit the Program Mode Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer Whil...

Page 24: ...arming Turning the system on or off as follows Arming Code P or Q Disarming Code U Arming Stay Arming with interior zones bypassed allowing free move ment within the premises Arming Away Arming with A...

Page 25: ...ce emergency Partitioned System A system that has been subdivided into two or more up to eight independent subsystems areas Pre Alarm Warning A keypad sounder alert of an impending alarm This option i...

Page 26: ...when the system is armed Burglary Zone Detects intrusion Day Zone A zone that will cause a visual and audible indication at the keypad if it is in trouble while disarmed Exit Entry Follower Zone Provi...

Page 27: ...uble Condition Action E 01 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call i...

Page 28: ...B The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with t...

Page 29: ...service E 15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E 16 NN Wireless Receiver Jam A problem has been detected with...

Page 30: ...rglary Bus Failure Call installing company for service E 24 Service Message The system is in need of a preventive maintenance service call E 27 00 Printer Failure Call installing company for service E...

Page 31: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 27 The Fire Alarm is sounding and...

Page 32: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Reviews: